1.Epidemiological characteristics and prevention strategy of Japanese encephalitis from 2003 to 2012 in Shaoguan
Liang XU ; Jianhong TANG ; Canlin QIU ; Ziqiang XU ; Changjie LI
International Journal of Laboratory Medicine 2014;(8):1001-1002
Objective Through the 2003 -2012 epidemic encephalitis B cases analysis ,to study the prevalence of epidemic en-cephalitis B in Shaoguan ,and to provide the scientific basis for the prevention and control epidemic encephalitis B .Methods Active surveillance of suspected cases ,retrospective analysis of laboratory confirmed cases related materials were done .Results There were 47 cases who suffered from epidemic encephalitis B in Shaoguan from 2003 to 2012 ,and 2 death cases occurred .Epidemic en-cephalitis B incidence in years was (0 -0 .531) /10 million .There was a morbidity peak in June and July ,which accounted for 87 .23% of the total incidence ,20 cases occurred in June(42 .55% )and 21 cases occurred in July(44 .68% ) .Men suspected cases in 130 cases ,31 laboratory confirmed cases .Women suspected cases in 86 cases ,16 laboratory confirmed cases .The positive cases of male was more than female .In 47 epidemic encephalitis B cases ,0- <4 years old 6 cases ,4- <7 years old 22 cases ,7- <20 years old 17 cases ,≥ 20 years old 2 cases .Most of the patients were preschool children and students ,accounting for 82 .97% .There were 32 cases with no or uncertain history of vaccination ,accounting for 68 .08% of the total cases .15 cases had history of immunity ,ac-counting for 31 .92% of the total cases .Conclusion Prevention of epidemic encephalitis B should pay more attention to epidemic en-cephalitis B vaccination .Mosquito control work of rural and peri-urban areas should be strengthened .
2.Study on radiation dose and image quality for dual-source CT angiography under ‘double low’ Scan program
Shang GE ; Chunhe LI ; Changjie PAN ; Tao WANG ; Liefu XU
Chinese Journal of Radiological Medicine and Protection 2015;35(3):226-230
Objective To explore the image quality and radiation dose for coronary angiography using DSCT (dual-source computed tomography) under lower tube voltage and lower contrast agent concentration ('double low').Methods A total of 160 patients with suspected coronary artery disease underwent dual-source CCTA.80 patients (BMI < 25 kg/m2) were randomly assigned to group A (270 mg I/ml-80 kV) and B (350 mg I/ml-120 kV).The other 80 patients (25 ≤ BMI <30 kg/m2) were randomly assigned to group C (270 mg I/ml-100 kV) and D (350 mg I/ml-120 kV),sonogram affirmed iterative reconstruction technology and 270 mg I/ml contrast agent were applied to group A and C ; FBP technology and 350 mg I/ml contrast agent were applied to group B and D.Adaptive cardio-sequence prospective ECG-gated technology was applied in all patients,while the acquisition phase was 65%-75% RR interval (when heart rate < 75 beats / min) or 40%-50% RR interval at when heart rate ≥ 75 beats/min.Volume CT dose index (CTDIvol),dose length product (DLP),effective dose (E),size specific dose estimates (SSDE),image noise,CT value,signal-to-noise ratio (SNR),and contrast-to-noise ratio(CNR) were all evaluated for each patient.Results There was not statistical difference in scan length among groups A and B,C and D.There was statistical difference in tube current between group A and B (t =8.932,P <0.05).There was not statistical difference in tube current between group C and D (tCD =-1.212,P > 0.05).There was statistical difference in CTDIvol,DLP,E and SSDE between group A and B,C and D (tCTDIvol =-16.141,-11.440 ; tDLP =-17.454,-10.521 ; t =-17.444,-10.523 ;tSSDE =-13.032,-9.119,P <0.05).Compared to group B,the SSDE in group A decreased by 64.4%.Compared to group D,the SSDE in group C decreased by 39.3%.There was no statistical difference in image noise between group A and B,C and D (P > 0.05).There was statistical difference in CT value,SNR and CNR between group A and B (t =0.436,4.623,3.272,P < 0.05).There was no statistical difference in CT value and CNR between group C and D,while there was statistical difference in SNR between group C and D (t =2.981,P <0.05).There was no statistical difference in image quality scores between group A and B,C and D (P > 0.05).Conclusion Compared with conventional DSCT coronary angiography,'double low' DSCT coronary scanning solution can significantly reduce the radiation dose and contrast agent,and could provide the effective coronary images which meet the clinical diagnostic needs.
3.Important role of ELMO1 in invasion and migration of breast cancer cells induced by IL-8
Changjie ZHANG ; Xinwei XU ; Hongli LI ; Yuqing LIU ; Chonggao YIN
Chinese Pharmacological Bulletin 2016;32(10):1452-1456,1457
Aim To explore the relationship between IL-8 and ELMO1 in breast carcinoma and the mecha-nisms of IL-8 induced invasion and metastasis. Meth-ods Under the IL-8 stimulation, chemotaxis assay was examined to detect the chemotaxis ability of breast cancer cell line MDA-MB-231 and MCF-7 . ELMO1 protein levels in breast cancer cell lines were detected using Western blot. MDA-MB-231 cells were transfect-ed with small RNA interference plasmids in order to downregulate ELMO1 expression, and overexpression plasmids were used to upregulate the expression of EL-MO1 in MCF-7 cells. Matrigel invasion assay and chemotaxis assay were used to detect the in vitro inva-sion and chemotaxis ability of breast cancer cells with IL-8 stimulation. Results IL-8 induced chemotaxis of the different breast cancer cell lines in a dose-depend-ent manner. After transient transfection, Western blot results showed that ELMO 1 protein levels observably decreased in SiELMO1/MDA-MB-231 cells compared with Scr/MDA-MB-231 cells, while the expression of ELMO1 protein levels significantly increased in MCF-7/ELMO1 cells compared with the MCF-7/Con cells;with IL-8 stimulation, SiELMO1/MDA-MB-231 cells showed significantly decreased chemotaxis ability com-pared with Scr/MDA-MB-231 cells. MCF-7/ELMO1 cells showed significantly increased chemotaxis ability compared with MCF-7/Con cells; the invasion assay showed under the stimulation of IL-8 , and the invasion ability was significantly reduced in SiELMO1/MDA-MB-231 cells compared with Scr/MDA-MB-231 cells ( P<0. 05 ) . The invasion ability was significantly en-hanced in MCF-7/ELMO1 cells compared with MCF-7 cells( P<0. 05 ) . Conclusion IL-8 promotes the in-vasion and migration of breast cancer cells MDA-MB-231 and MCF-7 , and ELMO1 plays an important role in IL-8 induced chemotaxis and invasion.
4.Application of “double low”technique in dual-source CT coronary angiography for low-weight patients
Shang GE ; Changjie PAN ; Qiang LI ; Weiliang RONG ; Liefu XU
Journal of Practical Radiology 2015;(4):650-654,662
Objective To explore the feasibility of “double low ”(low tube voltage and low contrast agent concentration)imaging technology of dual-source computed tomography (DSCT)in coronary angiography for low-weight patients.Methods 60 patients (BMI≤25 kg/m2 )who underwent coronary CT angiography (CCTA)on DSCT scanner were divided randomly into 2 groups:group A was “double low”group (n = 30,tube voltage = 80 kVp,using sinogram affirmed iterative reconstruction technology and 270 mg I/mL concentration of contrast agent);Group B was conventional group (n=30,tube voltage=120 kVp,using filtered back projection technology and 350 mg I/mL concentration of contrast agent).Adaptive cardiosequence prospective ECG-gated technology (CorAdSeq)was applied in both the groups,The collecting phase was 65%-75% RR interval (when heart rate<70 beats per mi-nute)or 40%-50% RR interval (when heart rate≥70 beats per minute).Subjective and objective methods were applied to evaluate the image quality.The image quality and.radiation dose were compared between the “double low”group and the conventional group by using SPSS 1 9.0 software.The differences between measurement data were analyzed by using independent samples t-test.Results The effective dose with size specific dose estimates (EDssde)of group A(1.22±0.31)mGy/cm was significantly lower than that of group B (3.44±0.80)mGy/cm with P <0.001.Contrast-noise ratio,signal-noise ratio and CT value of group A were signifi-cantly higher than those of group B (all P <0.05 ).Conclusion Compared with conventional DSCT coronary angiography,“double low”DSCT coronary scanning proposal for low-weight patients can significantly reduce the radiation dose and the amount of contrast agent,and the image quality can meet the needs of clinical diagnosis.
5.Effect of combined laparoscopic treatment of gallstone duodenoscope on common bile duct stones
Yanliang HAN ; Yongnan AN ; Junfeng YAN ; Changjie WANG ; Huancai XU
International Journal of Surgery 2010;37(8):508-511
Objective To study the effect of laparoscopic cholecystectomy endoscopic sphincterotomy combined with Oddi lithotomy (EST) treatment of gallbladder stone on common bile duct stones. Methods A retrospective analysis between May 2003 and June 2009 ,the combined treatment of LC and EST in 78 patients with common bile duct stones was retrospectivelly analyzed. First, bile duct stones were removed by EST, then laparoscopic cholecystectomy was performed within 5 days. Results EST was performed successfully in 76 cases (97%), failure in 2 cases, 1 case abdominal choledochojejunostomy due to the end of bile duct stenosis; one cases of common bile duct stone diameter of 1.6 cm, firm, failure of mechanical lithotripsy received common bile duct ploration T-tube drainage 76 cases of laparoscopic operation is successful, without obvious bleeding, bile leakage and other severe complications. Conclusions The advantages of EST + LC for the gallbladder stones and common bile duct stones with less trauma, faster recovery, fewer complications, and no T-tube drainage, etc; this is a safe and effective treatment.
6.CT appearance of ovary Brenner tumor: Five cases report
Changjie PAN ; Nong QIAN ; Wei LIU ; Yuejun XUE ; Yiqun XU
Chinese Journal of Medical Imaging Technology 2010;26(2):301-303
Objective To observe the CT features of ovary Brenner tumor. Methods CT manifestations of 5 patients with ovary Brenner tumor confirmed with pathology and clinical follow-up were retrospectively analyzed, and the masses were described for location, size, configuration, enhancement pattern, presence of calcification and metastatic spread. Results There were 7 tumors in 5 patients, 3 patients had unilateral tumors and 2 had bilateral Brenner tumors (left side 3 and right side 4), with tumor size ranging from 1.52 to 16.25 cm (mean 7.36 cm). Five masses in 4 patients were benign, 2 (bilateral tumors in 1 patient) were malignant. All tumors had well-defined margin. One patient with bilateral benign tumors had large pleural effusion and seroperitoneum. Five tumors in 4 patients (5/7, 71.43%) were solid and had calcification, 2 tumors in 1 patients (2/7, 28.57%) were mainly cystic, with septa in the tumors. The solid part of all tumors were inhomogeneous and had mild enhancement. Conclusion CT findings of ovary Brenner tumor have some characteristics. Combining with clinical manifestations, CT is helpful for the diagnosis of ovary Brenner tumor.
7.Prospective study on the value of CARE kV technique in reducing the radiation dose in adult chest CT imaging
Yiqun XU ; Mingzhu MENG ; Nong QIAN ; Changjie PAN ; Yuejun XUE
Chinese Journal of Radiological Medicine and Protection 2013;33(6):664-667
Objective To explore the application of CARE kV technique in the adult chest CT and the value of reducing radiation dose.Methods Sixty-nine patients were divided into two groups by random number generators:group A(39 cases) and group B(30 cases).Group A was examined by using CARE kV technique and group B was examined at routine 120 kV.CT dose index(CTDIvol),dose length product (DLP) and effective dose (E) were compared between the two groups,and analyzed the correlation between tube voltage selection and patient body mass index (BMI) of group A was analyzed.Results The average CTDIvol [(11.00 ± 3.89) mGy],DLP[(294.05 ± 91.17) mGy·cm] and E[(4.12 ± 1.28) mSv] of group A were lower than those of group B (16.64 ± 1.20) mGy,[(475.99 ± 41.16) mGy · cm],[(6.66 ±0.58) mSv].With statistically significant difference (t =-7.653,-10.151,-10.150,P < 0.05).Compared with routine 120 kV technique (group B),the CARE kV technique (group A) could reduce the total radiation dose about 38.14%.Compared obese patients(BMI≥28 kg/m2) with non-obese patients in group A and B,the mean E of non-obese patients was lower than that of obese patients in group A,which reduced the total E about 31.74% (t =4.322,P <0.05),while E in group B was no significant different between non-obese patients and obese patients.Conclusions In adult chest CT,CARE kV technique can select optimum scanning voltage automatically according to the patients with different BMI and anatomical regions,which can reduce the overall radiation dose while maintaining image quality.
8.In-Vitro Culture of Different Explants from Andrographis paniculate (Burm. f.) Nees
Hong HE ; Changjie HUANG ; Changhui LIU ; Yuru LI ; Honghua XU
Journal of Guangzhou University of Traditional Chinese Medicine 2004;0(06):-
[ Objective ] To supply a technological evidence for the rapid reproduction of Andrographis paniculata (Burm. f.) Nees (APN). [Methods] Different explants from sterile seedling of Andrographis paniculata (Burm. f.) Nees were cultured in vitro to induce the production of fascicular buds. [ Results ] Cotyledon with nodes and half cotyledon with nodes were the most suitable explants for culture, and the budding rate was 100% and over 90% respectively. 6-Benzylaminopurine (BA) in the concentrations of 0.5 ~ 1.0mg/L were beneficial for the reproduction and growth of buds. The age of explants had no correlation with budding. The optimal rooting medium was MT (Murashige and Tucher) medium added with Img/L NAA (naphthaleneacetic acid) or IBA (indolebutyric acid). A highest rooting rate as much as 61.9% was achieved after 10 days of culture. [Conclusion] An effective plant regeneration system has been established for explants of Andrographis paniculata (Burm. f.) Nees.
9.Studies on Skin Permeation in vitro of Phloretin and Ligustilide in Fufang Phloretin Cream
Yang ZHANG ; Qingwei WANG ; Huanhuan ZHAO ; Changjie LI ; Yuan XU
China Pharmacist 2017;20(6):1038-1041
Objective: To determine the transdermal absorption of phloretin and ligustilide in Fufang phloretin cream.Methods: In vitro percutaneous absorption test using the Franz intelligent transdermal absorption apparatus was adopted, an HPLC method was used to determine the contents of phloretin and ligustilide in the accepting solution at different time points, and then the cumulative release amount and the total penetration amount were calculated to evaluate the percutaneous absorption behavior.Results: Phloretin and ligustilide showed a good linearity within the range of 0.044 2-4.42 μg·ml-1(r=0.999 9) and 0.048 7-4.87 μg·ml-1(r=0.999 9), respectively, the average recovery was 99.85% and 99.92%, and RSD was 0.67% and 0.66% (n=9), respectively.The in vitro permeation behavior of phloretin and ligustilide through the skin of rats fit Higuchi equations(r>0.9), suggesting a good linear correlation between the cumulatine penetration amount (Qn) and (time).Conclusion: Fufang phloretin cream has a good percutaneous permeation property in vitro.
10.Preliminary study of low-dose CT coronary angiography by using low concentration isotonic contrast agent
Changjie PAN ; Tao WANG ; Nong QIAN ; Liefu XU ; Yiqun XU ; Lian JIN ; Qi ZHAO
Chinese Journal of Radiology 2014;48(10):800-804
Objective To compare the iodine intake,image quality and radiation dose of dual-source CT coronary artery angiography between the low concentration isotonic contrast agent with iterative reconstruction technique of sinogram affirmed iterative rEconstruction (SAFIRE) and common concentration contrast agent with filtered back projection (FBP).Methods One hundred patients [58 men,42 women; age:(62± 11)y] were enrolled in this study.Fifty consecutive patients (Group A) were scanned with FBP and common concentration contrast agent and another 50 consecutive patients (Group B) were scanned with low concentration isotonic contrast agent and iterative reconstruction technique.The image quality were assessed by two experienced radiologists with a double blinded fashion in a five score scale.The attenuation of coronary artery,scan time,imaging noise,signal-to-noise ratio (SNR),contrast-to-noise ratio (CNR),radiation dose and iodine intake between these two groups were compared using two sample t test.The observer agreement for image quality was calculated using Kappa statistics.Results All examinations were completed successfully.There was no statistical difference (P>0.05) between two groups in clinical characteristics and scan parameters.There was no statistical difference for the mean subjective image quality of group A (4.4±0.7) and group B (4.3±0.8) (t=0.924,P>0.05).The Kappa value between two radiologists was 0.887 (P<0.01)on image quality.The mean attenuation of coronary artery segments was higher than 300 HU,especially in group A (386.1±51.5) HU,which was slightly higher than the group B (384.1±77.1) HU,but there was no statistical difference (t=0.157,P>0.05).The SNR and CNR in two groups did not have significant differences (P>0.05).The total iodine and iodine injection rates were 21.0 g,17.5 g/s in Group A and 16.2 g,13.5 g/s in Group B,respectively.The iodine intake was decreased by 22.9% in Group B.The effective radiation dose in Group B (1.09±0.19) mSv was significantly (t=20.260,P<0.01) lower than that in Group A (2.85±0.59) mSv,with the radiation dose reduced by 61.8%.Conclusion Low concentration isotonic contrast agent and iterative reconstruction technique can significantly reduce the radiation dose and iodine intake in CT coronary artery angiography and achieve the same image quality using common concentration contrast agent with FBP.