3.Repeatability of macular thickness profiles of intra-retinal layers determined by an automated algorithm with Cirrus HD-OCT
Sheng, YANG ; Chang-Zheng, CHEN ; Jing-Heng, LIU
International Eye Science 2017;17(8):1558-1561
AIM: To evaluate the repeatability and reproducibility of thickness profile measurement of intra-retinal layers determined by an automated algorithm applied to OCT images from Cirrus optical coherence tomography (OCT) instrument.METHODS: In this prospective cross-sectional study,retinal thickness images at 6mm×6mm around fovea were obtained from 86 eyes of 43 normal subjects with Cirrus HD-OCT instrument.The retinal images from patients were analysis by Cirrus automated algorithm GCA software,including ganglion cell layer and inner plexiform layer(GCIPL).During this study,operator A would make 2 times measurements to all patients,after that operator B would make another 2 times measurements by Repeat scan model.All the data,including GCL average thickness,min thickness,12 clock average thickness,2 clock average thickness,4 clock average thickness,6 clock average thickness,8 clock average thickness and 10 clock average thickness were measured by SPSS 15.0 software.Standard deviation (SD),coefficient of variation (CV) and interclass correlation coefficient (ICC) were calculated from the results of three-times tests by different examiner to evaluate the repeatability and from the results of two different examiners to assess the reproducibility.Written informed consent was obtained from each subject prior to any medical procedure.RESULTS: The average GCIPL thickness of OD was 85.12±3.95μm;the minimum average GCIPL thickness was 83.21±4.41μm;the standard deviation of OD in clock map was from 3.79μm to 4.84μm;CV(95%CI) was between 0.26 and 0.93;ICC was from 0.939 to 0.989.The average GCL+IPL thickness of OS was 84.65±8.73μm;the minimum average GCPL thickness was 81±13.08μm;the standard deviation of OS in clock map was from 8.24μm to 10.56μm;CV(95%CI) was between 0.92 and 4.94;ICC was from 0.264 to 0.968.CONCLUSION: Cirrus HD-OCT GCA software with automated algorithm can offer accurate and repeatable thickness profile of OCT retinal image.GCA is a useful and reliable approach to the measurement of intra-retinal layer thickness,which may improve the diagnosis and monitoring of retinal diseases.
4.Correlation of Isokinetic Parameter and Modified Ashworth Scale Applied in Evaluation of Ankle Spasticity
Siyu DENG ; Xi LU ; Shuyan QIE ; Chang LIU ; Sheng BI
Chinese Journal of Rehabilitation Theory and Practice 2016;22(2):178-183
Objective To study the correlation between isokinetic parameters and modified Ashworth Scale (MAS) in ankle spasticity as-sessment. Methods 18 stroke patients (spasticity group) and 16 healthy subjects (control group) in our hospitals from August 2014 to March 2015 were included. MAS was used to assess the ankle muscular tension. The ankle passive movement of both groups was measured with BIODEX isokinetic motor assessment system under 10 °/s, 60 °/s, 120 °/s, 180 °/s, 240 °/s. The peak torque (PT), peak torque/body weight (PT/BW), average torque (AT), and slopes of the linear regression curve of torque-velocity (SLOPE) were recorded. The correlation of the isokinetic paramenters and the MAS were tested with Spearman correlation analysis. Results The PT, PT/BW and AT were higher in the spasticity group than in the control group (P<0.05). And they increased as the angular velocity increased, and slowed after 120 °/s. The corre-lation coefficient of MAS and PT, PT/BW, AT, SLOPE were from 0.3043 to 0.7632 (P<0.01). Conclusion The isokinetic parameters were speed-dependent and closely related to MAS. 120 °/s was of the highest sensitivity, and the SLOPE under this anglular velocity was highly correlated with MAS.
6.Effect of light quality on growth and quality of Pinellia ternata.
Yun CHEN ; Guo-Sheng ZHU ; Qiao-Sheng GUO ; Chang-Lin WANG ; Zuo-Yi LIU
China Journal of Chinese Materia Medica 2013;38(24):4257-4262
Measuring the content of soluble reducing sugar, total sugar, soluble protein, guanosine, alkaloids, and succinic acid of Pinellia ternata tuber were measured by anthrone-sulfuric acid colorimetric method, Coomassie brilliant blue method, RP-HPLC, reverse potentiometric titration, acid dye colorimetry, respectively. The result showed that yellow light could promote the growth and development of P. ternata and increase the content of soluble reducing sugar, total sugar, alkaloids, and succinic acid. Under blue light could promote the content of soluble protein and guanosine. Red and yellow light increased the content of chlorophyll a and chlorophyll b, contrastively blue light reduced the content of chlorophyll a and chlorophyll b. White film through the most uniform spectrum was most conducive to the synthesis of chlorophyll a. As single film, blue film, yellow film were more conducive to the synthesis of chlorophyll a, green film and red film had been relatively beneficial to the synthesis of chlorophyll b. Bulbil formed the largest number and the biggest propagation coefficient of P. ternata under red light showed that it could increase the production of P. ternata under red light.
Carbohydrate Metabolism
;
radiation effects
;
Chlorophyll
;
metabolism
;
Light
;
Pinellia
;
growth & development
;
metabolism
;
radiation effects
;
Plant Leaves
;
growth & development
;
radiation effects
;
Plant Proteins
;
chemistry
;
metabolism
;
Quality Control
;
Solubility
7.The experimental study on selective portal vein embolization inducing ipsilateral hepatocellular apoptosis and contralateral hepatic hypertrophy in rabbit liver
Chang-Xue JI ; Yi-Long MA ; Xian CHEN ; Sheng-Qiu OU ; Xiao-Bo FENG ; Da-Sheng QIU ; Yu-Lin LIU ;
Journal of Interventional Radiology 2006;0(11):-
Objective To explore the best time point for the ipsilateral hepatocellular apoptosis and the contralateraI hepatic hypertrophy after selective portal vein embolization(SPVE)in rabbit.Methods In a randomized study design,forty rabbits were divided into 5 groups with 8 rabbits per-group,including one as the control and the other 4 were treated with SPVE during open surgery.The rabbits were killed postoperatively,in 3,7,14,21 days respectively after the embolization.The hepatic lobes volume,the ipsilateral hepatocellular necrosis rates and apoptosis index,and liver functions were determined as well. Results In the treatment groups,the average amount of the right liver volumes decreased from 46.4 cm~3 preoperatively to 46.0,44.4,42.0,39.7 cm~3 in groups of 3,7,14,21 days postoperatively;meanwhile,the left liver volumes increased from 54.0 cm~3 preoperatively to 54.5,56.3,61.7,63.9 cm~3 respectively during 3, 7,14,21 days after the procedures.The rates of future remaining live volumes(FRLV)increased from 53.8% preoperatively to 54.2%,55.9%,59.0%,61.0% at 3,7,14,21 days postoperatively.The apoptosis indexes of hepatocells from group A to E were 8.1%,12.2%,19.4%,20.1%,14.2% respectively.Conclusions SPVE leads to atrophy of the ipsilateral hepatic lobe and hypertrophy of contralateral lobe,indicating that hepatocytes undergone apoptosis,rather than necrosis.The time point is 7 to 14 days.
8.Perioperative glycosylated haemoglobin concentrations and glucose levels in Roux-en-Y gastric bypass GK rats
Bin LIU ; Sheng HUANG ; Chang WANG ; Yibo WANG ; Yabin JIAO ; Lufie DAI ; Ruijiao LIN ; Yu WANG
Chinese Journal of General Surgery 2012;27(1):40-43
Objective To analyze the related factors associated with the effect of Roux-en-Y gastric bypass in Goto-Kakizaki rats.Methods In GK rats undergoing Roux-en-Y gastric bypass,the weight,food intake,and the fasting blood glucose were retrospectively analyzed before surgery and 1,3,6,12,24 weeks after surgery,and the glycosylated haemoglobin concentrations were retrospectively analyzed before surgery and 4,12,24 weeks after surgery.According to preoperative glycosylated haemoglobin concentrations,GK rats were divided into 3 groups(group A,HbAlc 6.5%-7.9%; group B,HbAlc 8.0%-9.9% ; group C,HbAlc > 10%).Results The fasting blood glucose and the glycosylated haemoglobin concentrations significantly decreased 1 week after surgery(P < 0.01),on 24 weeks after operation,the fasting blood glucose levels decreased from(12.1 ± 3.0)mmol/L to(7.6 ± 1.3)mmol/L,and the glycosylated haemoglobin concentrations declined from(9.2% ± 1.8%)to(6.3% ± 0.8%).Preoperative fasting blood glucose was(11.1 ± 2.2)mmol/L and(15.8 ± 2.3)mmol/L respectively,and the preoperative glycosylated haemoglobin concentration was(8.6% ± 1.4%)and(11.5% ± 1.4%)respectively(P < 0.01).Non-conditional Logistic regression analysis identified preoperative glycosylated haemoglobin concentrations as an independent predictor for the cure rate(P < 0.01); Differences were significant between group A and group C,and group B and group C on the efficiency of the surgery(P <0.01).Conclusions Significant correlation established between glycosylated haemoglobin concentrations and the efficiency of the surgery,especially for those rats with preoperative HbAlc < 10%.
9.The Changes of Glutathione and Ergosterol in Saccharomyces cerevisiae Under High Pressure
Chang-Sheng QIAO ; Bo-Ning LIU ; Xu XU ; Shi-Ru JIA ;
China Biotechnology 2006;0(01):-
The growth changes of glutathione (GSH) and ergosterol in Saccharomyces cerevisiae (CICC1447 and CICC1339) were detected under 0.5Mpa pressure with compressed high-pure air (O-2∶N-2=21∶79). The results showed that logarithmic phases of the two strains were delayed; their biomass and special growth rate were lower than those of control sample (0.1MPa) and the double time were prolonged under 0.5MPa. High-pressure could increase the content of GSH obviously, compared to ambient atmosphere control samples. When the holding time was 3h, the content of GSH and ergosterol in CICC1447 increased 42.6% and 20.1%, respectively. However, the content of GSH in CICC1339 increased 58.7% when the holding time was 6h, while ergosterol content reduced. The results indicated that different yeast strains have different stress-response mechanism to copy with high-pressure shock.
10.Measurement and comparison of corneal flap thickness between Wavelight FS200 femtosecond laser and Moria 90 microkeratome LASIK by OCT
Chang-bin, ZHAI ; Ying-juan, HAO ; Sheng-ping, YI ; Juan, LIU ; Jing, ZHANG ; Yue-hua, ZHOU
Chinese Journal of Experimental Ophthalmology 2013;31(8):770-774
Background Lasein situ keratomileusi(LASIK) imainstream surgery forefractive correction,and femtosecond laseimuch often used to create thin corneal flap.The measuremenof OPTOVUE RTVue-100 OCto flap and stromal bed thicknesseofferuseful basifoLASIK.Ican be used in measuring the thicknesand shape of the corneal flap.Buthe study on the comparison of flap thicknesbetween WavelighFS200 femtosecond laseand MoriM2 microkeratome 90 μm-knife (Mori90 microkeratome) LASIK by OCilack.Objective The aim of thitrial wato compare the featureof corneal flapcreated by the WavelighFS200 femtosecond laseand Mori90 microkeratome.Methodpiloand prospective study wadesigned.Written informed consenwaobtained from each patienprioto LASIK.Sixty righeyeof 60 patientwith myopiomyopiastigmatism were enrolled in thiclinical trial.The patientwere randomized into the FS200 femtosecond lasegroup and Mori90 microkeratome group with matching demography.RTVue OCwaused to measure flap thicknesusing 10 settingon the 60 eye1 month afteoperation.The featureof the LASIK flapwere analyzed based on the measuring outcomes.ResultThe central flap thickneswa(112±3) μm and the mean flap thickneswa(112 ±3) μm in the FS200 femtosecond lasegroup,which wasignificanlowethan the central flap thicknesa(121±7) μm and the mean flap thicknesa(128±11) μm in the Mori90 microkeratome group respectively (P=0.031,0.030).Corneal flapin the FS200 femtosecond lasegroup showed flashape and thain the Mori90 microkeratome group wameniscushape.The central flap thickneswanoevidently differenfrom thaof peripheral thicknesin the FS200 femtosecond lasegroup (P =0.320).However,in the Mori90 microkeratome group,the central flap thickneswaobviously thinnethan thain the peripheral thicknes(P=0.038).The mean deviation between the actual and predicted flap thicknes(110 μm) wa(3±4)μm in the FS200 femtosecond lasegroup and (17±10) μm in the Mori90 microkeratome group,showing significandifference between them (P =0.009).ConclusionRTVue OCdeterminethathe shape of flapcreated by the FS200 femtosecond laseimore uniform and closeto the expected thicknesof 110 μm than the onecreated by the Mori90 microkeratome.OPTOVUE RTVue-100 OCiuseful tool to evaluate the flap shape and thicknesafteLASIK.