1.Clinical study of the femoral neck fractures in adult.
Yu Gwon JANG ; Young Chang KIM ; Jung Hwan SON ; Jang Suk CHOI ; Young Goo LEE
The Journal of the Korean Orthopaedic Association 1991;26(4):1113-1121
No abstract available.
Adult*
;
Femoral Neck Fractures*
;
Femur Neck*
;
Humans
2.THREE-DIMENSIONAL COMPARISON OF FRAMEWORK DISPLACEMENTS JOINED BY VARIOUS CONNECTION TECHNIQUES.
Jang Seop LIM ; Young Chan JEON ; Chang Mo JEONG
The Journal of Korean Academy of Prosthodontics 1999;37(3):358-374
This study measured the relative displacements of the five-unit fixed partial dentures as cast with the same fixed partial dentures sectioned and assembled by investment-soldering, soldering stand-soldering, and cast-joining techniques. A total of fifteen specimens using a type IV gold alloy wee one-piece cast as control and then sectioned and assembled five test specimens for each method were prepared. A computerized three dimensional coordinate measuring machine and specially designed cylinder for this study were used. Displacement was defined by six displacement variables for the each of cylinders incorporated in each casting: three component displacements ( Lx, Ly, and Lz) and rotational displacements( thetax, thetay, thetaz). The global displacement was computed using the mathematical formula R= Global displacement ={{{{rm SQRT { (x'-x)^2 +(y'-y)^2 + (z'-z)^2} }} }} Under the conditions of this study, the following conclusions were drawn: 1. The investment-soldering group showed the largest mean value of final global displacements, followed by stand-soldering group, cast-joining group and one-piece cast group. However, between the mean values of final global displacement for the cast-joining group and one-piece cast group, there was no significant difference. 2. For investment-soldering and stand-soldering groups, the greater global displacements were recorded in soldering phase than in indexing or investing phase. 3. For one-piece cast group, the displacements occured mostly in the casting phase. And for castjoining group, there was no significant difference in global displacements among the fabrication procedures. 4. Intercentroidal distance decreased in framework-pattering, solder-indexing, solder-standing, and soldering phases, but increased in investment block-investing and casting phases. 5. Specially designed cylinder for touch-trigger type coordinate measuring machine was validated.
Abstracting and Indexing as Topic
;
Alloys
;
Denture, Partial, Fixed
;
Investments
;
Methods
3.Statistical Analysis and Comparative Study of Breast Volume and Measurements in Korean Females.
Young Woo JANG ; Sung Gyun JUNG ; Chang Hyun KIM
Journal of the Korean Society of Plastic and Reconstructive Surgeons 1999;26(4):707-713
A study of the volume and linear measurements of the breast to determine new nipple positions for 142 subjects was undertaken. Volume determination was done by using the Grossman-Roudner device. The size and shape of the female breast may differ significantly, and such size and linear measurements have to be measured accurately prior to breast aesthetic surgery. Statistical analysis of these results are closely related to physical constitution(height, weight, chest circumference). There have been increasing changes in linear measurement and decreasing changes in breast volume during the last 10 years, The results were as follows: 1) the mean distance from the midclavicular point to the nipple was 19.5cm, the distance from the sternal notch to the nipple was 19.4cm, the distance between nipples was 18.6cm, and the areolar diameter was 3.3cm, 2) the regression equation for the midclavicular point to the nipple was 7.236+ 0.00077x height(cm)+ 0.233 x weight(kg), for the sternal notch to the nipple was 8.845-0.0039 x height(cm)+ 0.214x weight(kg), for the distance between nipples was 11.192 - 0.0033xheight(cm)+ 0.151x weight(kg), and for the areolar diameter was 4.031+0.02xheight(cm)-0.048 x weight(kg),3) the mean value of breast volume of the left side was 209.6cc, and that of the right side was 211.8cc, 4) the regression equation for the mean breast volume was -137.673 + 6.668 x weight(kg), which was equal to -528.414 + 9.115x chest circumference under the axilla(cm) and -468.420 + 8.298 x chest circumference across the nipple (cm). In conclusion, these data could be useful for numerous aspects of breast surgery, including augmentation mammoplasty, mastopexy, reduction mammoplasty, and correction of asymmetrical breasts as the standard for Korean females, if we know the body constituents (weight, chest circumference) before surgery.
Breast*
;
Female*
;
Humans
;
Mammaplasty
;
Nipples
;
Thorax
4.Erratum: Challenges and Considerations in Sequence Variant Interpretation for Mendelian Disorders
Young Eun KIM ; Chang Seok KI ; Mi Ae JANG
Annals of Laboratory Medicine 2019;39(6):606-606
This erratum is being published to revise the website address of the Korean Reference Genome Database (KRGDB) and correct two typographical errors in the article.
5.The treatment of septic arthritis of the knee.
Young Ill KIM ; Young Chang KIM ; Jang Suk CHOI ; Young Goo LEE
The Journal of the Korean Orthopaedic Association 1992;27(3):781-786
No abstract available.
Arthritis, Infectious*
;
Knee*
6.COLORIMETRIC ANALYSIS OF COLOR DIFFERENCES BETWEEN DENTIN PORCELAINS.
Chang Seop KIM ; Jang Seop LIM ; Chang Mo JEONG ; Young Chan JEON
The Journal of Korean Academy of Prosthodontics 1999;37(4):425-432
The purpose of this study is to evaluate the color differences that can exist between differnet brands of dentin porcelain having identical shade designations. The instrumental colorimetric technique was used to determine these differences. The three brands of dentin porcelain used were Vita VMK-68, Shofu Vintage, and Ceramco II. The three shades selected were the Vita Lumin shades A2, B2, and C2. The color difference values were compared with each other using L*, a*, b*, three variables of the CIELAB color system, and E. The results of this study were as follows: 1. Corresponding shades of different brands of dentin porcelain produced different L*, a*, b* values. 2. The greatest E value in corresponding shade was found to exist between Ceramco II and Shofu Vintage, followed by between Vita VMK-68 and Ceramco II, and then between Vita VMK-68 and Shofu Vintage. 3. The E values in shade C2 were mainly influenced by L* value ; however none of L*, a*, b* values had greater influence on E values than the others in shade A2, B2. 4. Shofu Vintage had the highest b* value, followed by Vita VMK-68, and then Ceramco II.
Dental Porcelain*
;
Dentin*
7.Clinical study of the cementless total hip replacement arthroplasty.
Yu Gwon JANG ; Cheol KWAK ; Jang Suk CHOI ; Young Chang KIM ; Jung Hwan SON ; Young Goo LEE
The Journal of the Korean Orthopaedic Association 1992;27(4):871-879
No abstract available.
Arthroplasty*
;
Arthroplasty, Replacement, Hip*
8.Epidural Butorphanol Reduces the Side Effects from Epidural Morphine after Cesarean Section.
Dong Gi JANG ; Won Young CHANG ; So Young YOON ; Kyung Bae KIM
Korean Journal of Anesthesiology 1997;33(2):297-303
BACKGROUND: Epidural morphine has side effects, especially pruritus, nausea, and vomiting. Butorphanol has been added in studies to reduce these side effects in post cesarean patients. The purpose of this study was to evaluate the side effects and analgesic efficacy when a combination of epidural morphine and butorphanol was administered in patients having combined local anesthetic and opioid epidural infusion. METHODS: Sixty patients having epidural anesthesia for cesarean section were randomly divided into two groups. Group M (n=30) received a bolus of 0.25% bupivacaine 4 ml, morphine 2 mg, and saline 0.75 ml, whereas group B (n=30) received a bolus of 0.25% bupivacaine 4 ml, morphine 2 mg, and butorphanol 1.5 mg (0.75 ml). Continuous epidural infusion was done by Two-day Infusor containing either 0.25% bupivacaine 75 ml, morphine 5 mg, and saline 20 ml in group M or 0.25% bupivacaine 75 ml, morphine 5 mg, butorphanol 4 mg (2 ml), and saline 18 ml in group B. We compared the side effect and analgesic effect of group M to those of group B for 2 days. RESULTS: The incidence of pruritus and vomiting were reduced significantly in group B (p<0.05). There were no significant differences between both groups in the incidence of nausea or other side effects as well as no differences in analgesic effect. CONCLUSIONS: We conclude that the addition of butorphanol to morphine in combined local anesthetic and opioid epidural infusion for postoperative analgesia decreases the occurrence of pruritus and vomiting without significant increase of other side effects and adverse effect on analgesia.
Analgesia
;
Anesthesia, Epidural
;
Bupivacaine
;
Butorphanol*
;
Cesarean Section*
;
Female
;
Humans
;
Incidence
;
Infusion Pumps
;
Morphine*
;
Nausea
;
Pregnancy
;
Pruritus
;
Vomiting
9.Primary osteosarcoma of the cervical spine: a case report.
Sang Ho PARK ; Young Chang KIM ; Jang Seak CHOI ; Young Goo LEE
The Journal of the Korean Orthopaedic Association 1992;27(2):606-609
No abstract available.
Osteosarcoma*
;
Spine*
10.Result of total hip arthroplasty with bone graft in acetabular deficiency.
Cheol KWAK ; Young Chang KIM ; Jang Seok CHOI ; Young Ku LEE
The Journal of the Korean Orthopaedic Association 1992;27(4):900-906
No abstract available.
Acetabulum*
;
Arthroplasty, Replacement, Hip*
;
Transplants*