1.Use of new radiochromic devices for peripheral dose measurement: potential in-vivo dosimetry application
Biomedical Imaging and Intervention Journal 2009;5(4):1-12
The authors have studied the feasibility of using three new high-sensitivity radiochromic devices in measuring the
doses to peripheral points outside the primary megavoltage photon beams. The three devices were GAFCHROMIC®
EBT film, prototype Low Dose (LD) Film, and prototype LD Card. The authors performed point dosimetry using these
three devices in water-equivalent solid phantoms at x = 3,5,8,10, and 15 cm from the edge of 6 MV and 15 MV photon
beams of 10x10 cm2, and at depths of 0, 0.5 cm, and depth of maximum dose. A full sheet of EBT film was exposed
with 5000 MU. The prototype LD film pieces were 1.5x2 cm2 in size. Some LD films were provided in the form of a
card in 1.8x5 cm2 holding an active film in 1.8x2 cm2. These are referred to as “LD dosimeter cards”. The small LD
films and cards were exposed with 500 MU. For each scanned film, a 6 mm circular area centered at the measurement
point was sampled and the mean pixel value was obtained. The calibration curves were established from the calibration data for each combination of film/cards and densitometer/scanner. The doses at the peripheral points determined from the films were compared with those obtained using ion chamber at respective locations in a water phantom and general agreements were found. It is feasible to accurately measure peripheral doses of megavoltage photon beams using the
new high-sensitivity radiochromic devices. This near real-time and inexpensive method can be applied in a clinical
setting for dose measurements to critical organs and sensitive patient implant devices.
2.Intra-articular Nodular Fasciitis: An Unexpected Diagnosis for a Joint Lesion: A Case Report
MF Michelle Chan ; KO Ong ; SS Leon Foo ; S Selvarajan
Malaysian Orthopaedic Journal 2014;8(2):63-65
Pathological lesions in and around a joint can arise
from underlying dermis, subcutis, deep muscle, bone or
synovium. Clinical presentation can include joint pain,
joint swelling, palpable masses and mechanical restriction.
Whilst giant cell tumour of tendon sheath, pigmented
villonodular synovitis, synovial chondromatosis, lipoma
arborescens, juxta articular myxomas and inflammatory
arthritis are the better-known conditions of the joint.
Intra-articular nodular fasciitis, on the other hand, is less
well recognized both clinically and radiologically. It is
rarely seen in routine practice and is only described in case
reports in the literature. Due to the non-specific clinical
and radiological findings as well as the unfamiliarity with
the entity, the diagnosis of intra-articular nodular fasciitis
is usually clinched only after histological examination.
We present a case of intra-articular nodular fasciitis arising
in the knee joint which was not suspected clinically or
radiologically
Knee Joint
3.Evaluation of imaging performance of major image guidance systems
Chan MF* ; Yang J ; Song Y ; Burman C ; Chan P ; Li S
Biomedical Imaging and Intervention Journal 2011;7(2):1-7
Purpose: The imaging characteristics of two popular kV cone-beam CT (CBCT) and two MVCT systems utilised in
image-guided radiation therapy (IGRT) were evaluated.
Materials and methods: The study was performed on Varian Clinac iX, Elekta Synergy S, Siemens Oncor, and
Tomotherapy. A CT phantom (Catphan-504, Phantom Laboratory, Salem, NY) was scanned for measurements of image
quality including image noise, uniformity, density accuracy, spatial resolution, contrast linearity, and contrast resolution.
The measurement results were analysed using in-house image analysis software. Reproducibility, position correction,
and geometric accuracy were also evaluated with markers in a smaller alignment phantom. The performance evaluation
compared volumetric image properties from these four systems with those from a conventional diagnostic CT (CCT).
Results: It was shown that the linearity of the two kV CBCT was fairly consistent with CCT. The Elekta CBCT
with half-circle 27-cm FOV had higher CT numbers than the other three systems. The image noises of the Elekta kV
CBCT, Siemens MV CBCT, and Tomotherapy fan-beam CT (FBCT) are about 2-4 times higher than that of the Varian
CBCT. The spatial resolutions of two kV CBCTs and two MV CBCTs were 8-11 lp/cm and 3-5 lp/cm, respectively.
Conclusion: Elekta CBCT provided a faster image reconstruction and low dose per scan for half-circle scanning.
Varian CBCT had relatively lower image noise. Tomotherapy FBCT had the best uniformity.
4.A Rare Case of a Distal Humerus Pathological Fracture from Klebsiella Pneumoniae Osteomyelitis: A Case Report
Chan MF, MBBS ; Kwek EBK, FRCS
Malaysian Orthopaedic Journal 2020;14(No.1):81-83
Klebsiella pneumoniae is one of the leading causative organisms in pyogenic liver disease. It can cause disseminated infections, but rarely to bone, and rarely in healthy hosts. We report an unusual case of a distal humerus fracture from osteomyelitis secondary to dissemination in a non-immuno-compromised patient. The patient was surgically managed with external fixation and insertion of anti-biotic beads, in conjunction with medical therapy via culture direct antibiotics. This report highlights the diagnostic approach and treatment options for these atypical cases.
5.Pregnancy Outcomes in COVID-19: A Prospective Cohort Study in Singapore.
Citra Nz MATTAR ; Shirin KALIMUDDIN ; Sapna P SADARANGANI ; Shephali TAGORE ; Serene THAIN ; Koh Cheng THOON ; Eliane Y HONG ; Abhiram KANNEGANTI ; Chee Wai KU ; Grace Mf CHAN ; Kelvin Zx LEE ; Jeannie Jy YAP ; Shaun S TAN ; Benedict YAN ; Barnaby E YOUNG ; David C LYE ; Danielle E ANDERSON ; Liying YANG ; Lin Lin SU ; Jyoti SOMANI ; Lay Kok TAN ; Mahesh A CHOOLANI ; Jerry Ky CHAN
Annals of the Academy of Medicine, Singapore 2020;49(11):857-869
INTRODUCTION:
Pregnant women are reported to be at increased risk of severe coronavirus disease 2019 (COVID-19) due to underlying immunosuppression during pregnancy. However, the clinical course of COVID-19 in pregnancy and risk of vertical and horizontal transmission remain relatively unknown. We aim to describe and evaluate outcomes in pregnant women with COVID-19 in Singapore.
METHODS:
Prospective observational study of 16 pregnant patients admitted for COVID-19 to 4 tertiary hospitals in Singapore. Outcomes included severe disease, pregnancy loss, and vertical and horizontal transmission.
RESULTS:
Of the 16 patients, 37.5%, 43.8% and 18.7% were infected in the first, second and third trimesters, respectively. Two gravidas aged ≥35 years (12.5%) developed severe pneumonia; one patient (body mass index 32.9kg/m2) required transfer to intensive care. The median duration of acute infection was 19 days; one patient remained reverse transcription polymerase chain reaction (RT-PCR) positive >11 weeks from diagnosis. There were no maternal mortalities. Five pregnancies produced term live-births while 2 spontaneous miscarriages occurred at 11 and 23 weeks. RT-PCR of breast milk and maternal and neonatal samples taken at birth were negative; placenta and cord histology showed non-specific inflammation; and severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2)-specific immunoglobulins were elevated in paired maternal and umbilical cord blood (n=5).
CONCLUSION
The majority of COVID-19 infected pregnant women had mild disease and only 2 women with risk factors (obesity, older age) had severe infection; this represents a slightly higher incidence than observed in age-matched non-pregnant women. Among the women who delivered, there was no definitive evidence of mother-to-child transmission via breast milk or placenta.
Abortion, Spontaneous/epidemiology*
;
Adult
;
COVID-19/transmission*
;
COVID-19 Nucleic Acid Testing
;
COVID-19 Serological Testing
;
Cohort Studies
;
Disease Transmission, Infectious/statistics & numerical data*
;
Female
;
Fetal Blood/immunology*
;
Humans
;
Infectious Disease Transmission, Vertical/statistics & numerical data*
;
Live Birth/epidemiology*
;
Maternal Age
;
Milk, Human/virology*
;
Obesity, Maternal/epidemiology*
;
Placenta/pathology*
;
Pregnancy
;
Pregnancy Complications, Infectious/physiopathology*
;
Pregnancy Outcome/epidemiology*
;
Pregnancy Trimester, First
;
Pregnancy Trimester, Second
;
Prospective Studies
;
RNA, Viral/analysis*
;
Risk Factors
;
SARS-CoV-2
;
Severity of Illness Index
;
Singapore/epidemiology*
;
Umbilical Cord/pathology*
;