1.A study on the bonding strength of resilient denture liners.
Sang Hoon LEE ; Chae Heon CHUNG
The Journal of Korean Academy of Prosthodontics 1992;30(3):411-436
No abstract available.
Denture Liners*
;
Dentures*
2.Diagnostic Efficiency of Lactate Dehydrogenase, Crreatine Kinase and Troponin T in Acute Myocardial Infarction.
Chae Hoon LEE ; Kyung Dong KIM ; Chung Sook KIM
Yeungnam University Journal of Medicine 1995;12(1):48-55
The present study was designed to evaluate the efficiency of total lactate dehydrogenase, total creatine kinase, LD1/LD2 ratio, CK-MB and newly developed troponin T in acute myocardial infarction. The level of troponin T was 0.010.02 pg/L in 34 healthy person, but the peak vaule of acute myocardial infarction ranged in 4.7-24.2 pg/L. Total lactate dehydrogenase was peaked in 1 to 3 days after chest pain and then progressively decreased, but LD1/LD2 ratio was persistently higher than 1.0 for 10 days in most patients. Total creatine kinase and CK-MB were peaked in 1-2 days, and normalized in 3-4 days, so they, were useful in early diagnosis of acute myocardial infarction, but not for the late stages of acute myocardiz l infarction. Troponin T is early elevated and persistently high level for more than 10 days. Comparing with total lactate dehydrogenase, total creatine kinase, LD1/LD2 ratio and CK-MB, troponin-T test improves the efficiency of serodiagnostic method for the detection of ischemic myocardial damage.
Chest Pain
;
Creatine Kinase
;
Early Diagnosis
;
Humans
;
Infarction
;
L-Lactate Dehydrogenase*
;
Lactic Acid*
;
Myocardial Infarction*
;
Phosphotransferases*
;
Troponin T*
;
Troponin*
3.Results of secondary antibiotics susceptibility test for gram negative bacilli resistant to primary susceptibility test in Yeungnam University Hospital.
Chung Sook KIM ; Kyung Dong KIM ; Chae Hoon LEE
Yeungnam University Journal of Medicine 1993;10(1):28-36
Major pathogenic Gramnegative organisms such as P. aeruginosa, Serratia species, E. coli, Enterobacter species which are isolated from the specimens in large medical centers are greatly resistant to the commonly used antibiotics. Gramnegative bacilli, which had been isolated in Yeungnam Uni rersity Hospital during the period from December 1992 to April 1993 and turned out to be resistant to the primary antibiotics susceptibility test for chloramphenicoi, ampicillin, eephaiothin,- geniamicitt, tetracyclin, amikin and tobramycin, were subjected to the secondary antibiotics susceptibility test for aztreonam, ceftazidime, ciprofloxacine, cefotaxime, cefamandole, piperacillin, ticarcillin and sulfamethoxazole trimethopime. Out of 315 tested organisms, 167 organisms (53%) were resistant to all secondary antibiotics in vitro. Antimicrobial activity of ceftazidime (37.1%), aztreonam (11. %), ciprofloxacine (7.9%) against Gram negative bacilli were slightly more active than other antibiotics tested, while cefamandole was not active to all the Gramnegative bacilli tested. According to the specimens, E. coli was the most frequently resistant organisms to the primary antibiotics from urine, A. baumanii, from respiratory system and wounds, and P. aeruginosa from various specimens. In summary, Gram negative bacilli resistant to the primarily applied antibiotics also were resistant to the secondary antibiotics. Rearrangement of the antibiotics disks for the antibiotic susceptibility test should be considered.
Amikacin
;
Ampicillin
;
Anti-Bacterial Agents*
;
Aztreonam
;
Cefamandole
;
Cefotaxime
;
Ceftazidime
;
Ciprofloxacin
;
Enterobacter
;
Piperacillin
;
Respiratory System
;
Serratia
;
Sulfamethoxazole
;
Ticarcillin
;
Tobramycin
;
Wounds and Injuries
4.Prevalence of HBV DNA in Packed Red Blood Cells.
Chae Hoon LEE ; Chung Sook KIM ; Dal Ho SONG
Yeungnam University Journal of Medicine 1995;12(2):339-346
Assays for HBsAg, HBV DNA, anti-HBc and anti-HBs of 285 units of packed red blood cells supplied by Taegu Red Cross Blood Center were performed to evaluate the correlation between the prevalence of HBV DNA and the serologic markers for hepatitis B virus. None of 285 plasma samples was positive for HBsAg, however, HBV DNA were detected by polymerase chain reaction in 2 samples which both presented only with anti-HBc positivity.. Of 204 samples tested for anti-HBs, 96 samples(47.1%) were positive and among 216 samples tested for anti-HBc, 80 samples(37.0%) were positive. Of 193 samples tested for both anti-HBs and anti-HBc, 80(41.1%) were all negative and 48(24.9%) were positive on both tests. Those samples which showed positivity only to anti-HBc were 25(13.0%). Considering the above results, transfusion-transmitted hepatitis B virus infection could be prevented by discarding anti-HBc positive blood, however, that may bring insufficient supply of donor bloods in the country like Korea where the prevalence of anti-HBc is high. Anti-HBc positive blood unequivocally positive for anti-HBs should be considered noninfectious for HBV and should be allowed to be transfused. It would reduce the amount of discarding donor blood as the routine blood donor screening tests presently used at Korea Red Cross Blood Center supplemented by anti-HBs and anti-HBc testing.
Blood Donors
;
Daegu
;
DNA*
;
Erythrocytes*
;
Hepatitis B Surface Antigens
;
Hepatitis B virus
;
Humans
;
Korea
;
Mass Screening
;
Plasma
;
Polymerase Chain Reaction
;
Prevalence*
;
Red Cross
;
Tissue Donors
5.The expression of subcloned human immunodeficiency virus genes microinjected into the amphibian oocyte.
Hoon CHOI ; Hong Kyun LEE ; Chae Gwan LEE ; Sung Goo KANG
Korean Journal of Obstetrics and Gynecology 1991;34(4):494-507
No abstract available.
Amphibians*
;
HIV*
;
Humans*
;
Oocytes*
6.Evaluation of Automated ESR Measuring system, SEDIsystem(TM).
Jung Ee LEE ; Kyung Dong KIM ; Chae Hoon LEE ; Chung Sook KIM
Yeungnam University Journal of Medicine 1996;13(1):110-115
The ESR is one of the oldest laboratory test still in use. Although it lacks specificity in diagnosis, it can be effective for monitoring disease activity and following-up. The Westergren method is used for reference method, however coefficient of variation has been described 0.8% to 22.9% according to the literature. Since the ESR was invented in 1921, measurement technique has developed and automated measurement is introduced. We analyzed one hundred forty-three patient samples using SEDIsystem' automated ESR measuring system and compared with modified Westergren and Wintrobe methods. Comparison between SEDIsystem' and modified Westergren for ESR measurement yields the following regression equation; y = 0.863x - 1.69 (r=0.830), SEDIsystem'M and Wintrobe y'= 1.14x - 14.7 (r=0.789), rcspectively. We repeated measurement to evaluate reliability, results are not significant in statistically. In conclusion, SEDIsysten' automated ESR measurement correlated with modified Westergren and Wintro" ; methods, reveal reliable results after 4 hours and can report rapidly for large samples. Thus, these results indicate that SEDIsystenT"' automated ESR measurement may be useful tool for clinical practice.
Diagnosis
;
Humans
;
Sensitivity and Specificity
7.Comparison study of AAS and ISE method in the lithium analysis of serum and urine.
Soo In LEE ; Chae Hoon LEE ; Kyung Dong KIM ; Chung Sook KIM
Yeungnam University Journal of Medicine 1993;10(2):409-416
In the method for lithium (Li) analysis, flame emission photometry and atomic absorption spectrophotometry (AAS) have been used most frequently. In addition, lithium can be analyzed by ion-selective electrode (ISE) or fluorscence polarization immunoassay. We evaluated the comparison between AAS method based on the principle of absorption of light at 670.8 nm by Li and ISE method based on the principle of voliage difference generated by Li in contact with lithium ionophore. We compared with those obtained by AAS (AA/AE Spectrophotometer 551, Instrumentation Laboratory Co.) and ISE (SYNCHRON EL-ISE, Beckman Co.) in the serum and urine of 6 pati,,:nts- and evaluated time-related changes of serum lithium concentration after dosing in both methods. The results are summarized-as follows: 1. In within-run precision study for lithium concentration, coefficient variations (CVs, %) ranged from 1.34 to 2.17 for AAS and from 0.34 to 0.85 for ISE method. In between-run precision study for lithium concentration, CVs ranged from 1.23 to 1.72 for AAS and from 0.61 to 1.38 for ISE method. 2. The correlation study between AAS and ISE method resulted in Y= 0.946X+ 0.137 (N = 32, r= 0. 933, X= AAS, Y= ISE) for serum lithium and Y= 1. 092X+ 0. 977 (N= 28, r= 0.943, X= AAS, Y= ISE) for urine lithium. 3. Time-related changes of serum lithium concentration in both AAS and ISE method resulted in peak serum levels about 2 hours after dosing and then rapidly decreased after the peak serum level and finally arrived at nearly initial levels about 9 hours after dosing. 4. The reference range of serum lithium was found as undetectable level for both AAS and ISE method and the reference range of urine lithium to the urine creatinine was 0 0.00014 mmol/mg(mean 0.00002 mmol/mg) for AAS method.
Absorption
;
Creatinine
;
Immunoassay
;
Ion-Selective Electrodes
;
Lithium*
;
Photometry
;
Reference Values
;
Spectrophotometry, Atomic
;
Statistics as Topic
8.Evaluation of Elecsys 2010 Electrochemiluminescent Immunoassay System.
Jung Ee LEE ; Hee Soon CHO ; Jin Young MUN ; Chae Hoon LEE ; Kyung Dong KIM
Korean Journal of Clinical Pathology 1997;17(6):1029-1037
BACKGROUND: Elecsys 2010 immunoassay system is based on the electrochemiluminescence immunoassay using a ruthenium (II) tris (bipyridyl) label. Since it was the first time to use the system in our laboratory, we would like to evaluate the analytical performances (precision, linearity and recovery rate) and correlation with radioimmunoassay (RIA) and microparticle enzyme immunoassay (MEIA) methods. METHODS: We used precicontrol tumor marker (TM1, TM2) for alpha-fetoprotein (AFP), prostatic specific antigen (PSA) and carcinoembryonic antigen (CEA), Precicontrol universal (Ul, U2) for triiodothyronine (T3) and thyroxine (T4), Precicontrol-TSH for thyrotropin (TSH) and pooled serum for the evaluation of precision and recovery rate. Patients' sera were used for the linearity and comparison study. RESULTS: The coefficients of variatron of Imprecision study were below; 4.0%, 8.7% and 10.2%, respectively in the within-run, within-day and between-day analysis. The recovery rates were 100.5%, 96.1% and 102.5%, respectively in T4, TSH, and AFP. The linearity were y=1.02x-0.182(r=0.99) for T4, y=1.01x+0.12 (r=0.99) for TSH and y=1.01x+0.54(r=1.00) for AFP. T3, T4, TSH, CEA and PSA results showed good correlation with RIA (r>0.90), but AFP showed r=0.88. Also, AFP, CEA and PSA results showed excellent correlation with AxSYM (r>0.99). CONCLUSION: Elecsys 2010 immunoassay system showed excellent precision, recovery rate, clinically acceptable linearity and good correlation with the results obtained by RIA and MEIA methods.
alpha-Fetoproteins
;
Carcinoembryonic Antigen
;
Immunoassay*
;
Immunoenzyme Techniques
;
Radioimmunoassay
;
Ruthenium
;
Thyrotropin
;
Thyroxine
;
Triiodothyronine
9.Massive Hemoptysis due to Acute Mitral Regurgitation with Sporadic Primary Mitral Valve Prolapse.
Won Young CHAE ; Sun Jin PARK ; Chi Woo SONG ; Byoung Hoon LEE ; Sang Hoon KIM ; Jae Hyung LEE
Korean Journal of Critical Care Medicine 2015;30(3):202-206
The most common cardiac cause of massive hemoptysis is mitral stenosis. Mitral regurgitation is rarely complicated by massive hemoptysis. A 48-year-old man with no significant medical history was admitted to our hospital with hemoptysis and production of 500 mL of blood within 24 hours. A pan-systolic murmur was found on chest examination. A chest computed tomography showed airspace consolidation in the right upper and middle lobes, with faint bilateral ground glass opacity. Echocardiography revealed mitral valve prolapse and grade IV mitral regurgitation. The patient was diagnosed with sporadic primary mitral valve prolapse. After mitral valve repair surgery, the patient recovered fully.
Echocardiography
;
Glass
;
Hemoptysis*
;
Humans
;
Middle Aged
;
Mitral Valve Insufficiency*
;
Mitral Valve Prolapse*
;
Mitral Valve Stenosis
;
Mitral Valve*
;
Thorax
10.Bacterial growth in artificially contaminated packed red cells following room temperature exposure.
Bo Chan JEONG ; Chae Hoon LEE ; Kyung Dong KIM ; Chung Sook KIM ; Dal Hyo SONG
Korean Journal of Blood Transfusion 1993;4(1):89-95
No abstract available.