1.Finite element analysis of stresses induced by osteointegrated prosthesis with or without connection between natural tooth and osseointegrated abutments.
The Journal of Korean Academy of Prosthodontics 1991;29(2):147-160
No abstract available.
Finite Element Analysis*
;
Prostheses and Implants*
;
Tooth*
2.A comparison of the form of the face, the dental arch and the maxillary central incisor.
The Journal of Korean Academy of Prosthodontics 1992;30(2):273-285
No abstract available.
Dental Arch*
;
Incisor*
3.A study on disclusion time of patient with temporomandibular dysfunction.
Hyeon Sin KWEON ; Chae Heon CHUNG
The Journal of Korean Academy of Prosthodontics 1993;31(1):63-76
No abstract available.
Humans
4.A study on the bonding strength of resilient denture liners.
Sang Hoon LEE ; Chae Heon CHUNG
The Journal of Korean Academy of Prosthodontics 1992;30(3):411-436
No abstract available.
Denture Liners*
;
Dentures*
6.Photoelastic analysis of stress induced by different type endosseous implants.
Chae Heon CHUNG ; Doo Ik CHANG
The Journal of Korean Academy of Prosthodontics 1993;31(4):661-678
No abstract available.
7.A STUDY OF INTERFACE AND CORROSION BEHAVIOR BETWEEN IMPLANT ABUTMENT AND CASTING GOLD ALLOY.
Mee Kyoung SON ; Jang Seon MA ; Chae Heon CHUNG
The Journal of Korean Academy of Prosthodontics 1999;37(5):672-686
The purpose of this study was to compare the casting problem and corrosion behavior in two types of HL Hexed abutments of the Steri-Oss system : gold/plastic coping and gold coping. The anodic Polarization behavior, the galvanic corrosion between abutments and Type III gold alloys, before and after casting were analyzed, and the crevice corrosion of casting samples was analyzed with the CPPT test and the SEM. The results are as follows ; 1. Anodic polarization behavior of samples ; Before casting, gold/plastic coping and gold coping was shown to have a similar corrosion patterns. TypeIII casting gold alloy was shown to have a lower corrosion potential and passivation film. Corrosion potential of the case of gold/plastic coping after casting was higher than that of gold coping, but the region of passivation film for gold/plastic coping was smaller than that of gold coping. 2. Galvanic corrosion behavior of samples ; Contact current density between casting gold alloys and gold/plastic before casting was higher than that between gold coping and casting gold alloy. Galvanic corrosion of samples after casting was shown to have similar contact current density. 3. Crevice corrosion behavior of samples ; Crevice corrosion resistance of casting sample using gold coping was lower than that of casting sample using gold/plastic coping, and a severe corrosion pattern was observed at the abutment-casting gold alloy interface by the SEM.
Alloys*
;
Corrosion*
;
Gold Alloys
8.Determination of antifungal ability of denture cleansing agents to candida albicans.
Sang Sup CHUN ; Chae Heon CHUNG ; Zang Hee LEE
The Journal of Korean Academy of Prosthodontics 1993;31(1):28-38
No abstract available.
Candida albicans*
;
Candida*
;
Dentures*
;
Detergents*
9.A COMPARATIVE STUDY ON THE FIT IN PROSTHESES USING PREMADE GOLD CYLINDER AND PLASTIC CYLINDER.
Seon Hee JUNG ; Jang Seon MA ; Chae Heon CHUNG
The Journal of Korean Academy of Prosthodontics 1999;37(6):825-834
Recently, various implant cylinders were supplied, especially received gold cylinders, cast cylinders produced from premade gold and plastic cylinders and plastic cylinders. This study measured and compared precise fit produced when using conventional gold and plastic cylinders. The comparative fit of lapped and non-lapped castings made from plastic pattern was examined. The implant/abutment interface fit was evaluated by scanning electron microscopy(SEM) for each of four cylinders. The following results were obtained: 1. The case of plastic cylinder showed 9.67+/-1.50micrometer gap Steri-Oss fixture was connected. 2. The case oflapped casting made from plastic cylinder showed 3.01+/-2.81micrometer gap when Steri-Oss fixture was connected. 3. The case of gold/plastic cylinder showed 9.80+/-1.68micrometer gap when Steri-Oss fixture was connected. 4. The case of gold cylinder showed 5.47+/-2.43micrometer gap when Steri-Oss fixture was connected. 5. In case of each cylinder which was connected with Steri-Oss fixture, the size of gap was showed less in the order of the case of gold/plastic cylinder, the case of plastic cylinder, the case of gold cylinder and the case of lapped casting made from plastic cylinder. As results of this study, the use of premade gold cylinder offers an advantage over plastic patterns in precise fit. When plastic patterns are used, polishing of implant cylinder components should provide precise fit.
Plastics*
;
Prostheses and Implants*
10.Photoelastic analysis of stress induced by fixed prostheses with rigid or nonrigid connection between natural tooth and osseointegrated implant.
Young Il KIM ; Chae Heon CHUNG ; Kyu Zong CHO
The Journal of Korean Academy of Prosthodontics 1993;31(2):271-300
No abstract available.
Prostheses and Implants*
;
Tooth*