1.Effects of Dexamethasone on expressions of IFN-gamma and IL-4 by PBMCs in response to IL-12.
Su Hak HEO ; Seong Beom LEE ; Gue Tae CHAE
Korean Leprosy Bulletin 2002;35(2):3-12
Dexamethasone is a widely used anti-inflammatory agent for a broad spectrum of diseases. The effectiveness of this agent is thought to be due to the capacity to modulate cytokine production in inflammatory cells. We examined the effects of dexamethasone on expressions of interferon gamma (IFN-gamma) and interleukin 4 (IL-4) by human peripheral blood mononuclear cells (PBMCs) in response to interleukin 12 (IL-12). Dexamethasone (10-5 M) inhibited IFN-gamma secretion, through direct suppression of IFN-gamma, IL-12 receptor (IL-12R) -beta1, and -beta2 expressions. Conversely dexamethasone increased IL-4 secretion as well as IL-4 expressions by PBMCs in response to IL-12. In addition, dexamethasone increased expression of suppressor of cytokine signalling (SOCS)-1, which inhibits JAK-STAT pathway of IL-12R signalling. The result of our study suggested that dexamethasone directly inhibited IFN-gamma expression, through suppression of IL-12 signalling and indirectly increases IL-4 expression, through suppression of IFN-gamma expression.
Dexamethasone*
;
Humans
;
Interferons
;
Interleukin-12*
;
Interleukin-4*
;
Receptors, Interleukin-12
2.Developing a Common Health Information Exchange Platform to Implement a Nationwide Health Information Network in South Korea.
Minho LEE ; Eunyoung HEO ; Heesook LIM ; Jun Young LEE ; Sangho WEON ; Hoseok CHAE ; Hee HWANG ; Sooyoung YOO
Healthcare Informatics Research 2015;21(1):21-29
OBJECTIVES: We aimed to develop a common health information exchange (HIE) platform that can provide integrated services for implementing the HIE infrastructure in addition to guidelines for participating in an HIE network in South Korea. METHODS: By exploiting the Health Level 7 (HL7) Clinical Document Architecture (CDA) and Integrating the Healthcare Enterprise (IHE) Cross-enterprise Document Sharing-b (XDS.b) profile, we defined the architectural model, exchanging data items and their standardization, messaging standards, and privacy and security guidelines, for a secure, nationwide, interoperable HIE. We then developed a service-oriented common HIE platform to minimize the effort and difficulty of fulfilling the standard requirements for participating in the HIE network. The common platform supports open application program interfaces (APIs) for implementing a document registry, a document repository, a document consumer, and a master patient index. It could also be used for testing environments for the implementation of standard requirements. RESULTS: As the initial phase of implementing a nationwide HIE network in South Korea, we built a regional network for workers' compensation (WC) hospitals and their collaborating clinics to share referral and care record summaries to ensure the continuity of care for industrially injured workers, using the common HIE platform and verifying the feasibility of our technologies. CONCLUSIONS: We expect to expand the HIE network on a national scale with rapid support for implementing HL7 and IHE standards in South Korea.
Computer Security
;
Computer Systems
;
Continuity of Patient Care
;
Delivery of Health Care
;
Electronic Health Records
;
Health Level Seven
;
Humans
;
Information Services*
;
Korea
;
Privacy
;
Referral and Consultation
;
Workers' Compensation
3.Relationships among Depression, Self-rated Health, Health Behaviors and Drug Abuse by Job Status.
Su Mi CHAE ; Jin Wook JEONG ; Sang Young LEE ; Kyung Hwa HEO
Korean Journal of Occupational Health Nursing 2015;24(3):245-257
PURPOSE: This study was performed to investigate the present condition of drug abuse and its association with depression, self-rated health and health behaviors by job status in Korean adults. METHODS: Data were derived from the study on four addiction problem and suicide in 2014. Multiple logistic regression was used to analyze patterns of drug abuse according to depression, self-rated health and health behaviors. RESULTS: The prevalence of drug abuse during the past year was 17.1% of the 4,018 subjects. About 3.3 times risk for drug abuse was found among individuals who had high depression scores. The risk of drug abuse was higher among those who were smoking (OR:1.46, 95% CI:1.17~1.83), drinking more frequently (OR:1.30, 95% CI:1.07~1.58), sleeping insufficiently (OR:1.31, 95% CI:1.03~1.67), eating irregularly (OR:1.45, 95% CI:1.19~1.76). Drug abuse problem was detected more seriously among employed than unemployed adults. CONCLUSION: Health-related behaviors, such as smoking, drinking, sleeping, eating should be considered simultaneously when designing strategies to deal with drug abuse problem, and it is important to understand the interaction between drug abuse and mental health. Furthermore, workplace based intervention can be effective in solving drug abuse problem.
Adult
;
Depression*
;
Drinking
;
Eating
;
Health Behavior*
;
Humans
;
Logistic Models
;
Mental Health
;
Prevalence
;
Smoke
;
Smoking
;
Substance-Related Disorders*
;
Suicide
4.Feasibility of Nerve Stimulator as a Supplemental Aid for Lumbar Transforaminal Epidural Block.
Dae Hee KIM ; Chae Hyun LIM ; Ju Yeong HEO ; Young Jae JANG ; Yong Soo CHOI
Clinics in Orthopedic Surgery 2014;6(3):324-328
BACKGROUND: The purpose of this study was to evaluate the clinical feasibility of an electric nerve stimulator in a lumbar transforaminal epidural block. METHODS: Using an electric nerve stimulator, transforaminal epidural blocks were performed in 105 segments of 49 patients who presented with lower back pain with radiating pain to lower extremities. The contrast medium was injected to delineate the nerve root after positioning an insulated needle at the intervertebral foramen under fluoroscopic guidance. Then, the nerve root was electrically stimulated with the insulated needle to confirm whether or not the same radiating pain was evoked. RESULTS: Of the 105 foraminal segments, the same radiating pain was evoked at 0.5 mAh in 47 segments (44.8%), at 1.0 mAh in 22 (21.0%), at 1.5 mAh in 3 (2.9%), at 2.0 mAh in 15 (14.3%), at 2.5 mAh in 4 (3.8%), and at 3.0 mAh in 5 (4.8%). No response was observed in 9 segments (8.6%). The fluoroscopy revealed successful positioning of the needle in the patients with an evoked radiating pain over 2.0 mAh. The visual analogue scale (VAS) obtained for pain improved from a mean of 7.5 to 2.7 after the block (p = 0.001). In the 9 cases without response to electrical stimulation, the patients showed an improvement on VAS from 7.8 to 3.4 (p = 0.008) also. CONCLUSIONS: A nerve stimulator can help to predict the accuracy of needle positioning as a supplemental aid for a successful lumbar transforaminal epidural block. It is sufficient to initiate a proper stimulation amplitude of the nerve at 2 mAh.
Adult
;
Aged
;
Aged, 80 and over
;
Analgesia, Epidural
;
*Electric Stimulation Therapy
;
Feasibility Studies
;
Female
;
Humans
;
Low Back Pain/etiology/*therapy
;
*Lumbar Vertebrae
;
Male
;
Middle Aged
;
*Nerve Block
;
Radiculopathy/etiology/therapy
;
Spinal Diseases/*complications
5.A comparative study on the fit and screw joint stability of ready-made abutment and CAD-CAM custom-made abutment.
Jong Wook KIM ; Yu Ri HEO ; Hee Jung KIM ; Chae Heon CHUNG
The Journal of Korean Academy of Prosthodontics 2013;51(4):276-283
PURPOSE: The purpose of this study was to investigate the fit and screw joint stability between Ready-made abutment and CAD-CAM custom-made abutment. MATERIALS AND METHODS: Osstem implant system was used. Ready-made abutment (Transfer abutment, Osstem Implant Co. Ltd, Busan, Korea), CAD-CAM custom-made abutment (CustomFit abutment, Osstem Implant Co. Ltd, Busan, Korea) and domestically manufactured CAD-CAM custom-made abutment (Myplant, Raphabio Co., Seoul, Korea) were fabricated five each and screws were provided by each company. Fixture and abutments were tightening with 30Ncm according to the manufacturer's instruction and then preloding reverse torque values were measured 3 times repeatedly. Kruskal-Wallis test was used for statistical analysis of the preloading reverse torque values (alpha=.05). After specimens were embedded into epoxy resin, wet cutting and polishing was performed and FE-SEM imaging was performed, on the contact interface. RESULTS: The pre-loading reverse torque values were 26.0 +/- 0.30 Ncm (ready-made abutment; Transfer abutment) and 26.3 +/- 0.32 Ncm (CAD-CAM custom-made abutment; CustomFit abutment) and 24.7 +/- 0.67 Ncm (CAD-CAM custom-made abutment; Myplant). The domestically manufactured CAD-CAM custom-made abutment (Myplant abutment) presented lower pre-loading reverse torque value with statistically significant difference than that of the ready-made abutment (Transfer abutment) and CAD-CAM custom-made abutment (CustomFit abutment) manufactured from the same company (P=.027) and showed marginal gap in the fixture-abutment interface. CONCLUSION: Within the limitation of the present in-vitro study, in domestically manufactured CAD-CAM custom-made abutment (Myplant abutment) showed lower screw joint stability and fitness between fixture and abutment.
Computer-Aided Design*
;
Torque
6.Palatal obturator restoration of a cleft palate patient with velopharyngeal insufficiency: a clinical report.
Yu Ri HEO ; Jong Wook KIM ; Gyeong Je LEE ; Chae Heon CHUNG
The Journal of Korean Academy of Prosthodontics 2013;51(4):353-360
Cleft lip and palate is congenital deformity in oral and maxillofacial area. Normal soft palate has velopharyngeal closure action by connecting oral cavity and nasal cavity at rest and moving upward at swallowing and specific pronunciation. Cleft palate patients with velopharyngeal insufficiency have difficulty in mastication, swallowing and pronunciation because velopharyngeal closure is incomplete. At this time, a prosthetic device used to cover palate defects is called a palatal obturator. A palatal obturator separates oral cavity and nasal cavity and recovers pronunciation, mastication, swallowing and esthetic function. The purpose of this case study is to report the results because it reaches a satisfactory result in functional and esthetic aspects through functional impression procedures using modeling compound and tissue conditioner for restoration of a cleft palate patient with velopharyngeal insufficiency.
Cleft Lip
;
Cleft Palate*
;
Congenital Abnormalities
;
Deglutition
;
Humans
;
Mastication
;
Mouth
;
Nasal Cavity
;
Palatal Obturators*
;
Palate
;
Palate, Soft
;
Velopharyngeal Insufficiency*
7.Comparison of fatigue fracture strength by fixture diameter of mini implants.
Yu Ri HEO ; Mee Kyoung SON ; Hee Jung KIM ; Han Cheol CHOE ; Chae Heon CHUNG
The Journal of Korean Academy of Prosthodontics 2012;50(3):156-161
PURPOSE: This study was conducted to obtain difference in fracture strength according to the diameter of one-body O-ring-type of mini implant fixture, to determine the resistance of mini implant to masticatory pressure, and to examine whether overdenture using O-ring type mini implant is clinically usable to maxillary and mandibular edentulous patients. MATERIALS AND METHODS: For this study, 13 mm long one body O-ring-type mini implants of different diameters (2.0 mm, 2.5 mm and 3.0 mm) (Dentis, Daegu, Korea) were prepared, 5 for each diameter. The sample was placed at 30degrees from the horizontal surface on the universal testing machine, and off-axis loading was applied until permanent deformation occurred and the load was taken as maximum compressive strength. The mean value of the 5 samples was calculated, and the compressive strength of implant fixture was compared according to diameter. In addition, we prepared 3 samples for each diameter, and applied loading equal to 80%, 60% and 40% of the compressive strength until fracture occurred. Then, we measured the cycle number on fracture and analyzed fatigue fracture for each diameter. Additionally, we measured the cycle number on fracture that occurred when a load of 43 N, which is the average masticatory force of complete denture, was applied. The difference on compressive strength between each group was tested statistically using one-way ANOVA test. RESULTS: Compressive strength according to the diameter of mini implant was 101.5 +/- 14.6 N, 149 +/- 6.1 N and 276.0 +/- 13.4 N, respectively, for diameters 2.0 mm, 2.5 mm and 3.0 mm. In the results of fatigue fracture test at 43 N, fracture did not occur until 2x106 cycles at diameter 2.0 mm, and until 5x106 cycles at 2.5 mm and 3.0 mm. CONCLUSION: Compressive strength increased significantly with increasing diameter of mini implant. In the results of fatigue fracture test conducted under the average masticatory force of complete denture, fracture did not occur at any of the three diameters. All of the three diameters are usable for supporting overdenture in maxillary and mandibular edentulous patients, but considering that the highest masticatory force of complete denture is 157 N, caution should be used in case diameter 2.0 mm or 2.5 mm is used.
Bite Force
;
Collodion
;
Compressive Strength
;
Denture, Complete
;
Denture, Overlay
;
Fatigue
;
Fractures, Stress
;
Humans
8.Acute Hyponatremic Encephalopathy after Ingestion of Polyethylene Glycol Solution before Colonoscopy.
Chae HEO ; Hyoung Chul OH ; Jeong Wook KIM ; Jae Gyu KIM
Korean Journal of Gastrointestinal Endoscopy 2009;39(3):169-171
Preparation for colonoscopy involves a thorough cleansing of the large bowel. Cleansing is performed using several methods, including ingestion of 4 liters of polyethylene glycol solution. However, these methods can induce hyponatremia by various mechanisms. Severe or rapidly progressing hyponatremia can result in the swelling of the brain, and the symptoms of hyponatremia are mainly neurological. Recently, we encountered a 41-year-old woman who developed acute hyponatremia with encephalopathy after undergoing bowel preparation for colonoscopy. She presented with general weakness, nausea, headache, agitation, delusions, and slurred speech one day after the ingestion of polyethylene glycol solution. Her serum sodium level was very low (110 to 115 mEq/L). Her symptoms pertaining to hyponatremia continued to persist for more than 2 days despite continuous intravenous administration of hypertonic saline for the correction of hyponatremia.
Administration, Intravenous
;
Adult
;
Brain
;
Colonoscopy
;
Delusions
;
Dihydroergotamine
;
Eating
;
Female
;
Headache
;
Humans
;
Hyponatremia
;
Nausea
;
ortho-Aminobenzoates
;
Polyethylene
;
Polyethylene Glycols
;
Sodium
9.The Effect of Hydroxyapatite Coating on Long-term Results of Total Hip Arthroplasty with Hydroxyapatite-coated Anatomic Femoral Stem.
Young Yool CHUNG ; Chae Hyun IM ; Dae Hee KIM ; Ju Yeong HEO ; Young Jae JANG
Hip & Pelvis 2014;26(3):143-149
PURPOSE: To evaluate the clinical and radiological results, as well as the survival rate, associated with total hip arthroplasty using a hydroxyapatite (HA)-coated anatomical femoral stem at a follow-up of > or =12 years. MATERIALS AND METHODS: From April 1992 to May 1997, 86 patients (102 hips) underwent total hip arthroplasty with a HA-coated ABG I (Anatomical Benoist Giraud; Howmedica) hip prosthesis. The average age at the time of surgery was 53.4 years and the mean duration of follow-up was 17.1 years (range, 12.1-21.0 years). The Harris hip score (HHS) and radiographic assessments of thigh pain were used to evaluate the clinical results. We observed osteointegration, cortical hypertrophy, reactive line, calcar resorption and osteolysis around the femoral stems. The survival rate of the femoral stems was evaluated by using the span of time to a revision operation for any reasons was defined as the end point. RESULTS: The mean HHS was 50.5 preoperatively and 84.2 at the time of last follow-up. Osteolysis only around the HA-coated proximal portion of the femoral stem was observed in 72 hips, cortical hypertrophy all around the distal portion of the femoral stem was observed in 38 hips, and calcar resorption was observed in 44 hips. A reactive line was observed in 13 hips, but was unrelated to component loosening. Stem revision operations were performed in 24 (23%) hips due to osteolysis (14 hips), fracture (5 hips) and infection (5 hips). The femoral stem survival rate was 75% over the mean duration of follow-up. CONCLUSION: Total hip arthroplasty using a HA-coated anatomical femoral stem showed necessitated a high rate of revision operations due to osteolysis around the femoral stem in this long term follow-up study.
Arthroplasty, Replacement, Hip*
;
Durapatite*
;
Follow-Up Studies
;
Hip
;
Hip Prosthesis
;
Humans
;
Hypertrophy
;
Osteolysis
;
Survival Rate
;
Thigh
10.Proximal Femoral Nail Antirotation versus Compression Hip Screw with Trochanter Stabilizing Plate for Unstable Intertrochanteric Hip Fractures.
Jae Young RHO ; Sang Bum KIM ; Youn Moo HEO ; Seong Jin CHO ; Dong Sik CHAE ; Woo Suk LEE
Journal of the Korean Fracture Society 2010;23(2):161-166
PURPOSE: To analyze and compare the clinical and radiologic results of treatments in unstable intertrochanteric fractures of the femur with proximal femoral nail antirotation (PFNA) and compression hip screw with trochanter stabilizing plate (CHS with TSP). MATERIALS AND METHODS: We retrospectively reviewed the results of 66 cases of unstable intertrochanteric fractures of the femur treated with PFNA (Group I) and CHS with TSP (Group II) which could be followed up for minimum a year. We evaluated several comparative factors such as operation time, blood loss, time to bone union, changes in neck-shaft angle, sliding of screw (or blade), complications, postoperative pain, social-function score of Jensen, and mobility score of Parker and Palmer. RESULTS: Group I showed shorter operation time and less blood loss with significance than group II (p<0.05), but there were no differences between the groups in the mean time to bone union, changes in neck-shaft angle, sliding of screw (or blade), complications, postoperative pain, and social-function score of Jensen (p>0.05). Two cases of cutting out of the blade through the femoral head were found in group I. One case of cutting out of the screw, one case of the breakage of the plate, and loosening of the plate were found in group II as complications. CONCLUSION: We think that there were no significant differences between PFNA and CHS with TSP in view point of radiologic and clinical outcomes in unstable intertrochanteric fractures of the femur, but PFNA is less invasive device than CHS with TSP, therefore it may be useful device in elderly patients.
Aged
;
Femur
;
Head
;
Hip
;
Hip Fractures
;
Humans
;
Nails
;
Postoperative Complications
;
Retrospective Studies