1.Design and experiment of guide wire tele-manipulation system based on laser mouse sensor.
Jie SHEN ; Shenglin LI ; Daguo CHEN ; Yonghua YAN
Chinese Journal of Medical Instrumentation 2012;36(1):32-35
In order to realize the guide wire tele-manipulation in intervention operation, a method for guide wire motion detection with laser mouse sensor is proposed and experiments are carried out. On that basis, a guide wire tele-manipulation system which consists of guide wire detection appliance, guide wire manipulation appliance, and master slave type software is designed. Experiments are conducted on the system and acquired needed data, so that relationships between operating time and the distance from guide wire tip to destination and the angle are analyzed. The results validate the feasibility of the system and provide good foundation for future research.
Catheterization
;
instrumentation
;
methods
;
Embolization, Therapeutic
;
instrumentation
;
Equipment Design
;
Lasers
2.Study on an actuation system for matrix control of the active catheter in a minimally-invasive intervention surgery.
Yi-li FU ; Hui-hui MA ; Xian-ling LI
Chinese Journal of Medical Instrumentation 2006;30(6):416-430
As it is impossible for an active catheter with a very small space to accommodate overmany lead wires in minimally-invasive surgery, a matrix network system is presented, in this paper, to control SMA actuators using minimum lead wires. Pulse current is adjusted by pulse width modulation (PWM) signals from the single-chip processor. In addition, multiple SMA actuators' cooperation helps the active catheter to succeed in guiding motion.
Alloys
;
Catheterization
;
instrumentation
;
Equipment Design
;
Minimally Invasive Surgical Procedures
;
instrumentation
3.Efficiency of electrocardiogram monitor for positioning the catheter tip in peripherally inserted central catheter placement in neonates.
Qi-Ying LING ; Hong CHEN ; Min TANG ; Yi QU ; Bin-Zhi TANG
Chinese Journal of Contemporary Pediatrics 2018;20(5):363-367
OBJECTIVETo study the efficiency of electrocardiogram (ECG) monitor for positioning the catheter tip in the placement of peripherally inserted central catheter (PICC) in neonates.
METHODSA total of 160 neonates who were admitted to the neonatal intensive care unit (NICU) from January 2015 to December 2017 and underwent the PICC placement via the veins of upper extremity were enrolled. They were randomly divided into an observation group and a control group, with 80 neonates in each group. The neonates in the control group were given body surface measurement and postoperative X-ray localization, while those in the observation group were given body surface measurement, ECG localization, and postoperative X-ray localization. The two groups were compared in terms of general information, one-time success rate of PICC placement, and time spent on PICC placement.
RESULTSThere were no significant differences between the two groups in sex composition, gestational age, age in days at the time of PICC placement, disease type, and site of puncture (P>0.05). Compared with the control group, the observation group had a significantly higher one-time success rate of PICC placement (95% vs 79%; P<0.05) and a significantly shorter time spent on PICC placement (P<0.05). Localization under an ECG monitor during PICC placement had a sensitivity of 97% and a specificity of 100%.
CONCLUSIONSDuring the PICC placement in neonates, the use of ECG monitor to determine the position of catheter tip can improve the one-time success rate of placement and reduce the time spent on placement.
Catheterization, Central Venous ; instrumentation ; Catheterization, Peripheral ; methods ; Catheters, Indwelling ; Electrocardiography ; instrumentation ; Female ; Humans ; Infant, Newborn ; Male
5.Discussion on packaging and marking of the sterile urethral catheter(catheterization bag).
Chinese Journal of Medical Instrumentation 2012;36(2):140-141
This paper gathered the problem in the Sterile Urethral Catheter(Catheterization bag)'s packaging and marking, analyzed the harmfulness and gave the improvement suggestion.
Disposable Equipment
;
Product Packaging
;
methods
;
Urinary Catheterization
;
instrumentation
;
Urinary Catheters
9.Open surgical insertion of Tenkchoff straight catheter without guide wire.
Shi-feng YANG ; Wu-jun XUE ; Ai-ping YIN ; Li-yi XIE ; Wan-hong LU
Chinese Medical Sciences Journal 2013;28(2):117-121
OBJECTIVETo compare the clinical outcomes of open surgical peritoneal dialysis catheter (PDC) insertion with guide wire and the outcomes of PDC insertion without guide wire.
METHODSData of the patients receiving open surgical Tenkchoff straight catheter insertion in our department from January 2005 to January 2011 were retrospectively analyzed. The 117 patients in whom PDC insertion was conducted with the guidance of guide wire were enrolled into group A, and the 121 cases receiving PDC insertion without guide wire were enrolled into group B. The incidences of post-operative complications (catheter obstruction, catheter displacement, bloody dialysate, and dialysate leakage), catheter survival, and patient survival rates were compared between the 2 groups.
RESULTSThe baseline characteristics (gender, age, body mass index, prothrombin time, activated partial thromboplastin time, platelet count, serum creatinine, follow-up time, primary diseases, and outcomes) of the 2 groups were comparable (all P>0.05). In post-operative complications, only the incidence of early bloody dialysate showed significant difference, being 16.2% in group A and 7.4% in group B (P=0.04). Catheter and patient survival rates were not significantly different between the two groups. Overweight patients showed a higher incidence of catheter obstruction compared with normal weight patients [16.0% (4/25) vs.3.3% (7/213), P=0.02], but no differences in post-operative complications were found among overweight patients between the 2 groups.
CONCLUSIONSOpen surgical Tenkchoff straight catheter insertion without guide wire does not lead to higher risk of post-operative complications and catheter removal. It may be an alternative option when guide wire is not available.
Adult ; Aged ; Catheterization ; adverse effects ; instrumentation ; methods ; Female ; Humans ; Male ; Middle Aged ; Peritoneal Dialysis ; instrumentation ; mortality ; Postoperative Complications ; etiology
10.Comparative study of 4Fr catheters using the ACIST variable rate injector system versus 6Fr catheters using hand manifold in diagnostic coronary angiography via transradial approach.
Lei HOU ; Yi-dong WEI ; Jing SONG ; Wen-liang CHE ; Wen-hui PENG ; Yong WANG ; Wei-ming LI ; Ya-wei XU ; Da-yi HU
Chinese Medical Journal 2010;123(11):1373-1376
BACKGROUNDThe transradial approach is regarded as a useful vascular site for coronary procedures. The aim of this study was to test whether 4Fr catheters assisted by ACIST variable rate injector system can produce comparable angiographic quality and reduce the risk of radial artery injury compared to hand manifold 6 Fr catheters.
METHODSA total of 1816 patients were studied consecutively, among whom 856 patients received coronary angiography by 4 Fr catheters (4Fr group) and 960 patients by 6 Fr catheters (6Fr group). Angiographic and procedural characteristics were observed and recorded. The luminal inner radial arterial diameter before and after the procedure were collected.
RESULTSThe baseline clinical characteristics were similar in both groups. There were no significant differences in procedure time, radiation dose and quality scores in both groups (P > 0.05), but more contrast media was delivered in the 6Fr group (P < 0.001). The mean radial arterial diameter six months after the procedure in the 6Fr group reduced significantly compared to that measured one day prior to the procedure (P < 0.001).
CONCLUSIONSCoronary angiography using the 4Fr catheters with Acist power injection system can achieve an acceptable diagnostic quality while at the same time minimizing radial artery injury and contrast media consumption.
Aged ; Cardiac Catheterization ; instrumentation ; Coronary Angiography ; instrumentation ; methods ; Female ; Humans ; Male ; Middle Aged ; Radial Artery ; diagnostic imaging ; Ultrasonography