1.Improving clinical research of arrhythmia in children.
Chinese Journal of Pediatrics 2003;41(10):721-723
Arrhythmias, Cardiac
;
therapy
;
Biomedical Research
;
methods
;
standards
;
Catheter Ablation
;
Child
;
China
;
Drug Therapy
;
Humans
2.Terminology and Reporting Criteria for Radiofrequency Ablation of Tumors in the Scientific Literature: Systematic Review of Compliance with Reporting Standards.
Tae Wook KANG ; Hyunchul RHIM ; Min Woo LEE ; Young Sun KIM ; Dongil CHOI ; Hyo Keun LIM
Korean Journal of Radiology 2014;15(1):95-107
OBJECTIVE: To perform a systematic review of compliance with standardized terminology and reporting criteria for radiofrequency (RF) tumor ablation, proposed by the International Working Group on Image-Guided Tumor Ablation in 2003, in the published reports. MATERIALS AND METHODS: Literature search in the PubMed database was performed using index keywords, PubMed limit system, and eligibility criteria. The entire content of each article was reviewed to assess the terminology used for procedure terms, imaging findings, therapeutic efficacy, follow-up, and complications. Accuracy of the terminology and the use of alternative terms instead of standard terminology were analyzed. In addition, disparities in accuracy of terminology in articles according to the medical specialty and the type of radiology journal were evaluated. RESULTS: Among the articles (n = 308) included in this study, the accuracy of the terms 'procedure or session', 'treatment', 'index tumor', 'ablation zone', 'technical success', 'primary technique effectiveness rate', 'secondary technique effectiveness rate', 'local tumor progression', 'major complication', and 'minor complication' was 97% (298/307), 97% (291/300), 8% (25/307), 65% (103/159), 55% (52/94), 33% (42/129), 94% (17/18), 45% (88/195), 99% (79/80), and 100% (77/77), respectively. The overall accuracy of each term showed a tendency to improve over the years. The most commonly used alternative terms for 'technical success' and 'local tumor progression' were 'complete ablation' and 'local (tumor) recurrence', respectively. The accuracy of terminology in articles published in radiology journals was significantly greater than that of terminology in articles published in non-radiology journals, especially in Radiology and The Journal of Vascular and Interventional Radiology. CONCLUSION: The proposal for standardization of terminology and reporting criteria for RF tumor ablation has been gaining support according to the recently published scientific reports, especially in the field of radiology. However, more work is still needed for the complete standardization of terminology.
*Catheter Ablation
;
Female
;
*Guideline Adherence
;
Humans
;
Neoplasms/*surgery
;
*Terminology as Topic
;
Writing/*standards
3.Moving-Shot versus Fixed Electrode Techniques for Radiofrequency Ablation: Comparison in an Ex-Vivo Bovine Liver Tissue Model.
Eun Ju HA ; Jung Hwan BAEK ; Jeong Hyun LEE
Korean Journal of Radiology 2014;15(6):836-843
OBJECTIVE: To compare the ablation characteristics of the moving-shot technique (MST) and the fixed electrode technique (FET) for radiofrequency (RF) ablation in an ex-vivo bovine liver tissue model. MATERIALS AND METHODS: We performed RF ablation using FET in 110 bovine liver blocks using 11 different ablation times ranging from 5 seconds to 5 minutes (10 blocks per each time duration). Ten bovine liver blocks at each ablation time of 1- or 2-minute, were ablated with MST, which treated conceptual ablation units by moving the electrode tip. We evaluated the ablation volume obtained with FET across ablation time lengths. The results of FET and MST performed with the same ablation time lengths, i.e., 1- and 2-minute ablation time were also compared. RESULTS: The ablation volume achieved with FET gradually increased with increasing ablation time; however, the pair-wise statistical comparison between 2 neighboring ablation time lengths was not significant after 30 seconds. MST with either 1- or 2-minute ablation time achieved larger ablation volumes (1.1 +/- 0.2 mL vs. 2.7 +/- 0.3 mL, p < 0.001; and 1.4 +/- 0.2 mL vs. 5.6 +/- 0.4 mL, p < 0.001, respectively), longer true RF times (46.7 +/- 4.6 seconds vs. 60 seconds, p < 0.001; and 64.8 +/- 4.6 seconds vs. 120 seconds, p < 0.001, respectively), fewer numbers of RF cut-offs (1.6 +/- 0.5 vs. 0, p < 0.001; and 5.5 +/- 0.5 vs. 0, p < 0.001, respectively), and greater energy deposition (2050.16 +/- 209.2 J vs. 2677.76 +/- 83.68 J, p < 0.001; and 2970.64 +/- 376.56 J vs. 5564.72 +/- 5439.2 J, p < 0.001, respectively), than FET. CONCLUSION: The MST can achieve a larger ablation volume by preventing RF cut-off, compared with the FET in an ex-vivo bovine liver model.
Animals
;
Catheter Ablation/*standards
;
Cattle
;
Electrodes
;
Equipment Design
;
In Vitro Techniques
;
Liver/*surgery
;
Models, Biological
;
Temperature