1.Long non-coding RNA H19 promoted lung cancer cells migration and invasion through miR-107
Jiyuan LI ; Canbin ZHANG ; Xin MA ; Qiang WANG ; Xian WANG ; Shuaiyu ZHENG
Chinese Journal of Immunology 2017;33(9):1392-1397
Objective:To investigate the effect and the related mechanism of H19 on the invasion and migration ability of pancreatic cancer cells.Methods: The expression of H19 in tissues of pancreatic carcinoma and non-carcinoma adjacent tissues of pancreatic carcinoma were detected.qPCR was used to detect the expression of H19 in different pancreatic cancer cells.The migration and invasion ability of pancreatic cancer cells was detected after silencing H19 using wound healing assays and Transwell matrigel invasion assays.Dual-Luciferase Reporter Assay System was used to detect miR-107regulating H19.The expression of miR-107 in tissues of pancreatic carcinoma and non-carcinoma adjacent tissues of pancreatic carcinoma were detected.The regulation of miR-107 on the migration and invasion ability of pancreatic cancer cells were detected after silencing H19 using wound healing assays and Transwell matrigel invasion assays.Subcutaneous tumor was used to detect the size and volume of the tumor after inject the tumor cells.Immunohistochemistry was used to detect the expression of Ki67 and PCNA.Results: Compared with non-carcinoma adjacent tissues of pancreatic carcinoma,the expression of H19 of tissues of pancreatic carcinoma was significantly increased.The expression of H19 in pancreatic cancer cell A549 was highest.Silencing H19 could inhibit the migration of human pancreatic cancer A549 cells.miR-107 was the direct target of H19.Compared with non-carcinoma adjacent tissues of pancreatic carcinoma,the expression of H19 of tissues of pancreatic carcinoma was significantly decreased.After silencing H19,inhibiting the expression of miR107 could inhibit the migration of human pancreatic cancer A549 cells.Compared with the group of H19-siRNA,H19-siRNA+miR-107-inhibitor group mice tumor volume and weight were significantly bigger.Immunohistochemistry showed that compared with H19-siRNA group,the expression Ki67 and PCNA expression in H19-siRNA+miR-107-inhibitor group increased.Conclusion: H19 plays the role of tumor promotor factor in pancreatic cancer.H19 can affect the invasion and migration ability of pancreatic carcinoma cells by regulating miR-107.
2.Limb salvage for Gustilo III C open fracture of left humerus with limb ischemia and wound infection by microsurgery: A case report
Jiantao YANG ; Canbin ZHENG ; Ben’gang QIN ; Honggang WANG ; Ping LI ; Liqiang GU ; Jian QI ; Qingtang ZHU
Chinese Journal of Microsurgery 2021;44(2):223-225
Report a case sustained Gustilo type III C open fracture of the left humerus with brachial artery injury who has limb ischemia and wound infection after operation in June, 2014. To salvage the limb, performed cross limb vessel transfer to restore blood supply at one-stage. After multiple debridement, Flow-through flap transfer was performed for definitive reconstruction of the arterial injury and repair the wound in secondary stage. In the 3rd stage, cutting the pedicle of transposition vessels. Follow-up at 1 year after surgery, the patient's left upper limb had survived with limited movement and confirmed Flow-through the vessel reconstruction using CTA.
3. Central dislocation of the femoral head without involvement of anterior or posterior column of the acetabulum: a case report
Qiguang MAI ; Jiahui CHEN ; Canbin WANG ; Han LIU ; Tao LI ; Hua WANG ; Shicai FAN
Chinese Journal of Orthopaedics 2019;39(13):841-844
This study showed a case of a patient with central dislocation of the femoral head without involvement of anterior or posterior column of the acetabulum. The patient was associated with endocrine disorders caused by pituitectomy, severe osteoporosis caused by a long-term gulucocorticoids intake history, and poor bone quality of the quadrilateral plate. The direct impact of the femoral head on the quadrilateral plate after trauma resulted in purely central dislocation of the femoral head. 3D printing technique was used to print the fracture model for observation of the fracture morphology and the simulated operation before surgery. The variable-angle locking acetabular plate with a propeller-like shape was designed on the basis of the mirror of the ipsilesional semi-pelvis. This fracture was reduced via the lateral-rectus approach under direct vision. The quadrilateral surface fractures were fixed by the variable-angle locking acetabular plate which was used as a template for reduction. The follow up after surgery showed good reduction and fixation, equal length of double lower limbs, good positive and passive motion of the injured hip joint and without perioperative complications. This report describes an isolated quadrilateral plate fracture that has not yet been classified. It was effectively treated by using a customized variable-angle locking acetabular plate with a propeller-like shape via the lateral rectus approach.
4. Application of customized variable-angle locking acetabular wing plates in treatment of acetabular fractures in the elderly via the lateral-rectus approach
Han LIU ; Canbin WANG ; Jiahui CHEN ; Qiguang MAI ; Tao LI ; Hua WANG ; Yuhui CHEN ; Cheng YANG ; Haiyang HUANG ; Jianwen LIAO ; Shicai FAN
Chinese Journal of Orthopaedics 2019;39(10):596-603
Objective:
To evaluate clinical efficacy and surgical techniques of customized variable-angle locking acetabular wing plates in treatment of complex acetabular fractures in the elderly through the lateral-rectus approach.
Methods:
Data of 11 elder patients of complex acetabular fractures (mean age 75 y, range: 60-93 y; 8 males, 3 females) admitted to our department from March 2016 to March 2017 were retrospectively analyzed. According to Judet-Letournel classification of acetabular fractures, there were 2 cases of anterior column and posterior hemitransverse fractures, 9 cases of both-column fractures. The customized variable-angle locking acetabular wing plates were designed by mimics software and then produced before surgery. During the operation, the customized variable-angle locking acetabular wing plate was applied to reduction and fixation via the anterior lataral-rectus approach. The effect of fracture reduction was assessed by Matta's criteria. The clinical effect was assessed by Harris Hip score and the modified Merle d' Aubigné-Postal score at the 6th month of postoperative follow-up.
Results:
The average time of designing and producing customized variable-angle locking acetabular wing plates was 4 d (3-5 d), the average operation time was 95 min (45-150 min), and the average intraoperative bleeding was 600 ml (250-1 400 ml). All patients were followed up, with an average follow-up of 18 m (6-24 m). All fractures were healed, with an average healing time of 8 weeks (6-12 weeks). Reduction quality: excellent in 8 cases, good in 2 cases, poor in 1 case, with an overall excellent and good rate of 90.9%. The result of Harris Hip scoring: excellent in 7 cases, good in 3 cases, and acceptable in 1 case, with a total excellent and good rate of 90.9%; Modified Merle d' Aubigné-Postal soring: excellent in 6 cases, good in 3 cases, and acceptable in 2 cases, with an overall excellent and good rate of 81.8%. There were 2 cases of obturator nerve injury, 1 case of fat liquefaction of incision, 3 cases of traumatic hip arthritis. During the follow-up, no complications such as ectopic ossification, plate fracture and screw loosening were found.
Conclusion
The customized variable-angle locking acetabular wing plates in treatment of complex acetabular fractures in the elderly via the lateral-rectus approach can achieve satisfactory reduction and firm fixtation.
5.The lateral-rectus approach combined with preoperative simulation assisted by 3D printing for treatment of acetabular fractures in the elderly
Tao LI ; Canbin WANG ; Qiguang MAI ; Hua WANG ; Cheng YANG ; Hai HUANG ; Jianwen LIAO ; Shicai FAN
Chinese Journal of Orthopaedic Trauma 2019;21(6):516-523
Objective To explore the efficacy of the anterior lateral-rectus approach combined with preoperative simulation assisted by 3D printing for treatment of acetabular fractures in the elderly.Methods A total of 52 elderly patients with acetabular fracture were admitted to Department of Orthopaedics and Trauma,The Third Affiliated Hospital to Southern Medical University from January 2014 to December 2017.They were 36 males and 16 females,with an average age of 71.6 years (from 65 to 88 years).According to the Judet-Letournel classification,there were 5 anterior column fractures,6 transverse fractures,18 anterior and posterior hemi-transverse fractures,and 23 both-column fractures.For all cases a preoperative surgical simulation was implemented based on their 3D-printed acetabular models.A pre-bent reconstruction plate or a custom acetabular aliform plate was placed to fixate the fracture after reduction via the anterior lateral-rectus approach.The reduction quality,healing time,function of affected hip and complications were recorded.Results The operation time for this cohort ranged from 85 to 138 min (average,102 min);the intraoperative bleeding ranged from 280 to 750 mL(average,520 mL).Perioperatively,implant failure,wound infection or symptomatic lower extremity phlebothrombosis was observed in none of the patients.According to the Matta radiological evaluation,the postoperative reduction was rated as excellent in 40 cases,as good in 7 and as poor in 5 (an excellent and good rate of 90.4%).All cases were followed up for 6 to 18 (mean,10.6 months).All the acetabular fractures united after 8 to 20 weeks (average,12 weeks).According to the modified Merle d'Aubigne-Postal scoring at the final follow-up,the function of affected hip was categorized as excellent in 29 cases,as good in 12 and as fair in 11 (an excellent and good rate of 78.8%).Walking pain was experienced by 5 patients 6 months after operation,diagnosed by imaging examination as traumatic arthritis of the hip joint.Follow-ups observed no such complications as screw loosening or heterotopic ossification.Conclusion In the treatment of acetabular fractures in the elderly,the anterior lateral-rectus approach combined with preoperative simulation assisted by 3D printing can achieve effective reduction and fixation,decrease intraoperative hemorrhage,shorten operation time and reduce such complications as screw loosening caused by osteoporosis.
6.Research on the reuse of mismatched regenerated motor axons of brachial plexus and the effect of target organs on regeneration in rats
Kunliang WANG ; Houlin AN ; Honggang WANG ; Jiantao YANG ; Canbin ZHENG ; Liwei YAN ; Jintao FANG ; Wenting HE ; Bengang QIN
Chinese Journal of Microsurgery 2023;46(6):672-680
Objective:To confirm the reuse of mismatched regenerated motor axons of brachial plexus and explore the effect of target organs on their regeneration in a rat model.Methods:This study was carried out between January 2021 and December 2021 at the research laboratory of the Department of Microsurgery, Orthopaedic Trauma and Hand Surgery, the First Affiliated Hospital of Sun Yat-sen University. Animals were randomly assigned into 2 groups, as a regeneration group (RGen) with 5 subgroups and a reuse group (RUs) with 3 subgroups. There were 6 rats per subgroup with 42 rats in total. It was observed that in the groups of RGen1-4, after the transection and suture of the musculocutaneous nerve, the motor axons of the proximal end could accurately grow into the distal corresponding endoneural tube. It was also observed that in the mismatched regenerated group, motor axons were the axons that grew into the endoneurial tube of the lateral forearm cutaneous nerve (LFCN), and other non-target organ contacts were made to the regenerated nerves after mismatch. It was specifically further divided into RGen1, the group without an organ for nerve to make contact with; RGen2, the group with skin as the target organ with nerves contact by neurorrhaphy; RGen3, the group with skin as the target organ with originally reserved natural nerve contact; RGen4, the group with muscle as the target organ with nerves contact by neurorrhaphy and RGen5, a control group. After 8 weeks, the positive area (PA), mean density (MD) and integral optical density (IOD) were measured, with AChE and ChAT fluorescence staining of the medial branch of LFCN, to evaluate the regenerated nerves after mismatch. Of the RUs group, firstly, the innervating branches of the flexor carpi radialis (FCR) were dissected and exposed, then further assigned according to initially innervated FCR (RUs1), contacted with regenerated nerves after mismatch (RUs2) and denervated (RUs3), respectively. After 8 weeks, compound muscle action potential (CMAP) and wet weight ratio of FCR were taken. Masson staining of FCR was also performed to evaluate muscle reinnervation by the regenerated nerves after mismatch. Data analysis with One-Way ANOVA and Bonferroni 0.05 indicated a statistically significant difference.Results:In the RGen groups, after AChE staining, the PA, MD and IOD of RGen3 and RGen4 were higher than that of RGen1 and RGen5, and PA of RGen4 were higher than that of RGen2, with a statistically significant difference ( P<0.05). After ChAT staining, the values of PA and IOD of RGen3 and RGen4 were higher than that of RGen1 and RGen5, and PA of RGen4 were higher than that of RGen2, with a statistically significant difference ( P<0.05). In the RUs, electrophysiological assessment showed that no CMAP was observed in RUs3, there was no significant difference in Latency of RUs1 and RUs2. The difference was statistically significant ( P<0.05). Wet weight rate of muscle of RUs1 (98.91%±3.86%) was higher than that of RUs3 (86.67%±4.68%) with a statistically significant difference ( P<0.01), but no significant difference when compared with RU2 (92.74%±3.88%). Masson staining showed that the CVF value of RUs2 (8.61%±1.16%) was significantly higher than that of RUs1 (3.17%±0.76%), and statistic significantly lower than that of RUs3 (16.44%±2.26%)( P<0.01). Conclusion:Target organ contact can promote the regenerated nerves after mismatched regeneration, and the muscle target organs exhibit greater facilitation than the cutaneous target organs. Besides, regenerated nerves after mismatch can establish effective innervation with muscle target organs, comfirming their effective reuse.