1.Synthesis of N-(2-18F-fluoropropionyl)-L-glutamine and its biodistribution study in mice
Caihua TANG ; Ganghua TANG ; Siyuan GAO ; Shaoyu LIU ; Fuhua WEN ; Dahong NIE
Chinese Journal of Nuclear Medicine and Molecular Imaging 2016;36(2):112-115
Objective To synthesize 18F labeled N-(2-18 F-fluoropropionyl)-L-glutamine (18 F-FPGLN) for tumor PET imaging,and to perform its biodistribution study on normal mice and PC-3 tumorbearing nude mice.Methods 4-nitrophenyl-2-18F-fluoropropionate (18F-NFP) was synthesized on the MF2V-IT-I synthesizer and was purified by semi-preparative HPLC.Anhydrous 18F-NFP was added to a solution of L-glutanine t-butyl ester to synthesize 18F-FPGLN t-butyl ester,which was hydrolyzed by HCl (3 mol/L) and neutralized with NaOH (2 mol/L) solution.18F-FPGLN product was collected for further study.Biodistribution study was performed on normal Kunming mice and PC-3 prostate cancer tumor-bearing nude mice,respectively.Results 18F-FPGLN was synthesized with 10%-15% (decay uncorrected) overall radiochemical yield after 130 min of radiosynthesis.The radiochemical purity was higher than 96%.Rapid and high uptake of radiotracer was observed within the kidneys,and was quickly excreted through the urinary bladder.The uptake in kidney reached (35.0±1.2) %ID/g at 5 min post-injection,and descended to (1.5±0.3) %ID/g at 120 min.The liver,lung,heart and small intestine showed relatively moderate uptake of radioactivity.The uptake in the pancreas,muscle,spleen,stomach and brain was low,and the lowest uptake of (1.5±0.3) %ID/g was found in the brain at 30 min post injection.High accumulation of 18F-FPGLN in PC-3 xenograft was observed,and the tumor/muscle ratio reached 2.07 at 60 min post injection.Conclusion A novel N-position 18F-labeled glutamine analogs 18F-FPGLN,with favorable pharmacokinetic characteristics,is synthesized successfully,which makes it possible to perform tumor PET imaging using 18F-FPGLN subsequently.
2.Long Noncoding RNA MHRT Protects Cardiomyocytes against H2O2-Induced Apoptosis.
Jianying ZHANG ; Caihua GAO ; Meijuan MENG ; Hongxia TANG
Biomolecules & Therapeutics 2016;24(1):19-24
Acute myocardial infarction (AMI) remains a leading cause of morbidity and mortality worldwide. The exploration of new biomarkers with high sensitivity and specificity for early diagnosis of AMI therefore becomes one of the primary task. In the current study, we aim to detect whether there is any heart specific long noncoding RNA (lncRNA) releasing into the circulation during AMI, and explore its function in the neonatal rat cardiac myocytes injury induced by H2O2. Our results revealed that the cardiac-specific lncRNA MHRT (Myosin Heavy Chain Associated RNA Transcripts) was significantly elevated in the blood from AMI patients compared with the healthy control (*p<0.05). Using an in vitro neonatal rat cardiac myocytes injury model, we demonstrated that lncRNA MHRT was upregulated in the cardiac myocytes after treatment with hydrogen peroxide (H2O2) via real-time RT-PCR (qRT-PCR). Furthermore, we knockdowned the MHRT gene by siRNA to confirm its roles in the H2O2-induced cardiac cell apoptosis, and found that knockdown of MHRT led to significant more apoptotic cells than the non-target control (**p<0.01), indicating that the lncRNA MHRT is a protective factor for cardiomyocyte and the plasma concentration of MHRT may serve as a biomarker for myocardial infarction diagnosis in humans AMI.
Animals
;
Apoptosis*
;
Biomarkers
;
Diagnosis
;
Early Diagnosis
;
Heart
;
Humans
;
Hydrogen Peroxide
;
Mortality
;
Myocardial Infarction
;
Myocytes, Cardiac*
;
Plasma
;
Rats
;
RNA
;
RNA, Long Noncoding*
;
RNA, Small Interfering
;
Sensitivity and Specificity
3.Electrophysiological characteristics and cause analysis of ridge related reentry after catheter ablation of atrial fibrillation
Chenxi JIANG ; Changsheng MA ; Jianzeng DONG ; Xin DU ; Deyong LONG ; Ronghui YU ; Ribo TANG ; Caihua SANG ; Xueyuan GUO ; Jungang NIE ; Jiahui WU
Chinese Journal of Interventional Cardiology 2014;(5):273-277
Objective To identify the electrophysiological charateristics and cause of ridge gap related reentry after MI ablation in atrial ifbrillation patients. Methods Activation and entrainment mapping was performed in 82 redo cases for OAT recurrence in whom MI was ablated during the index produre. Once ridge gap related reentry was conifrmed, detailed mapping was performed in MI and ridge region. In addition, in 36 cases undergoing MI ablation and fulfilling criterion for bidirectional block, differential pacing was repeated at the ridge to identify a ridge gap. Results Out of 82 redo cases for OAT recurrence in whom MI was ablated during the index produre, 7 (8.5%) was found to be ridge gap related reentry. TCL was (247.9±19.2) ms, and the left atrial endocardial activation time was (145.4±17.7) ms, accounting for (58.5±3.2)%of TCL. However, wide double potential was recorded along the previous ablated MI line where PPI was (34.3±6.6) ms longer than TCL, while PPI was signiifcantly shorter at the ridge[PPI-TCL (11.4±3.9) ms, P<0.001]. Tachycardia was terminated at the ridge in 6 cases and at the corresponding site in coronary sinus in 1 case. No recurrence was found during follow-up for (11.1±4.5) months. In addition, in 36 patients undergoing MI ablation in whom criterion of bi-directional block was fuliflled, conduction gap located at the ridge was found in 5 (13.9%) cases. Conclusions MI ridge gap related reentry is a distinctive OAT, in which the ridge was used as the critical isthmus, whereas the previous ablated MI line is not part of the reentry. MI pseudo-block due to the ridge gap may lead to this type of recurrent tachycardia.
4.The management of cardiac tamponade complications during catheter ablation of atrial ifbrillation ;using different periprocedure anticoagulation strategies
Caihua SANG ; Jianzeng DONG ; Deyong LONG ; Ronghui YU ; Ribo TANG ; Rong BAI ; Nian LIU ; Ke CHEN ; Chenxi JIANG ; Man NING ; Songnan LI ; Yingwei CHEN ; Changsheng MA
Chinese Journal of Interventional Cardiology 2014;(4):210-214
Objective To observe the management and outcome of the cardiac tamponade patients during the ablation procedure using two different anticoagulation strategies. Methods All the patients developed tamponade during the ablation procedure were enrolled from January 2007 to December 2013 in our center. In group 1, warfarin was discontinued 3 to 5 days before the procedure and low molecular weight heparin (LMWH) was administered subcutaneously until ablation procedure day. In group 2, warfarin was not discontinued and the international normalized ratio INR was to maintained between 2 and 3. Results There were 27 patients (0.6%) developed cardiac tamponade out of a total 4487 patients received ablation in our center. The baseline clinical characteristics including age, left atrium, the heparin dose and ACT during the procedure had no signiifcant difference between the groups, except that the INR was higher in the group 2 (0.9±0.1 vs. 2.3±0.5, P<0.001). There was no signiifcant difference in the amount of pericardiac drainage between the two groups (365±222 ml vs. 506±300 ml, P=0.137). Two patients in group 1 patient (11.1%) and 1 in group 2 (11.1%) needed emergency surgical repair (P>0.999). The median hospital day was similar in the 2 groups [(9.6±3.3) d vs. (12.1±4.5) d, P=0.167]. There were no other serious complications and no hospital death. Conclusions Non-discontinuation of warfarin during peri-procedural catheter ablation of AF is not signiifcantly different to bridging with LMWH in the management and outcome of acute cardiac tamponade.
5.Characteristics of induced atrial arrhythmias and long-term follow-up after pulmonary vein isolation in ;patients with paroxysmal atrial ifbrillation
Chenxi JIANG ; Changsheng MA ; Jianzeng DONG ; Xin DU ; Jiahui WU ; Deyong LONG ; Ronghui YU ; Ribo TANG ; Caihua SANG ; Man NING ; Songnan LI ; Chang LIU
Chinese Journal of Interventional Cardiology 2014;(4):205-209
Objective Identify the mechanism of induced atrial arrhythmias after pulmonary vein isolation (PVI) in patients with paroxysmal atrial ifbrillation(PAF), and investigate its long-term prognosis. Methods All patients with PAF undergoing PVI and induction test afterwards between Feburary 2010 and October 2010 were included. The induction protocol was rapid pacing initiated at cycle length of 250 ms with progressive shortening in a decrement of 10 ms down to 180 ms or refractoriness. Isoproterenol of 2-4μg/min was administrated as well. Inducibility was deifned as induction of atrial arrhythmia lasting >1 min. The mechanism of induced tachycardia was identiifed by activation mapping and entrainment mapping under the guidance of CARTO system. All patients were followed up by 36 months. Results Forty-nine atrial tachycardia were induced in 39 (19.7%) patients, including 35 organized atrial tachycardia (OAT) and 14 atrial ifbrillation (AF). The LA diameter was signiifcantly larger in inducible group than non-inducible group (39.5±6.6 mm vs. 36.7±5.2 mm, P=0.004). Macroreentry was the most common mechanism in induced OATs (28, 80.0%), and mitral isthmus was the most common critical site (20, 40.8%), followed by cavo-tricuspid isthmus (12, 24.5%), PV (6, 12.2%), LA septum (4, 8.2%), superior vena cava (3, 6.1%) and LA roof (1, 2.0%). Conclusions The most common mechanism of induced tachycardia by IV isoproterenol and rapid pacing is MI and CTI dependent after PVI in PAF patients, which can be succssefully eliminated by liner ablation, not increasing long-term recurrence rate.
6.Long-term results of single-procedure catheter ablation for atrial fibrillationin pre-and post-menopausal women
Tao LIN ; Xing DU ; Rong BAI ; Yingwei CHEN ; Ronghui YU ; Deyong LONG ; Ribo TANG ; Caihua SANG ; Songnan LI ; Changsheng MA ; Jianzeng DONG
Journal of Geriatric Cardiology 2014;(2):120-125
Objectives To address whether menopause affects outcome of catheter ablation (CA) for atrial fibrillation (AF) by comparing the safety and long-term outcome of a single-procedure in pre-and post-menopausal women. Methods A total of 743 female patients who underwent a single CA procedure of drug-refractory AF were retrospectively analyzed. The differences in clinical presentation and outcomes of CA for AF between the pre-menopausal women (PreM group, 94 patients, 12.7%) and the post-menopausal women (PostM group, 649 patients, 87.3%) were assessed. Results The patients in the PreM group were younger (P<0.001) and less likely to have hypertension (P<0.001) and diabetes (P=0.005) than those in the PostM group. The two groups were similar with regards to the proportion of concomitant mitral valve regurgitation coronary artery disease, left atrium dimensions, and left ventricular ejection fraction. The overall rate of complica-tions related to AF ablation was similar in both groups (P=0.385). After 43 (16-108) months of follow-up, the success rate of ablation was 54.3%in the PreM group and 54.2%in the PostM group (P=0.842). The overall freedom from atrial tachyarrhythmia recurrence was simi-lar in both groups. Menopause was not found to be an independent predictive factor of the recurrence of atrial tachyarrhythmia. Conclusions The long-term outcomes of single-procedure CA for AF are similar in pre-and post-menopausal women. Results indicated that CA of AF appears to be as safe and effective in pre-menopausal women as in post-menopausal women.
7.Three-dimensional ultrasound guided catheter ablation of premature ventricular components originating from left anterior ventricular papillary muscles via transspetal puncture
Deyong LONG ; Liping SUN ; Jin WANG ; Ronghui YU ; Ribo TANG ; Caihua SANG ; Chenxi JIANG ; Songnan LI ; Yucai HU ; Xin DU ; Jianzeng DONG ; Changsheng MA
Chinese Journal of Interventional Cardiology 2017;25(6):321-325
Objective To investigate ablation characteristics of PVC/VT originating from left ventricle anterior papillary muscles.Methods This study included 10 patients of PVC/VT originating from left ventricle anterior papillary muscles from January 2015 to June 2016 in Beijing Anzhen Hospital.Electrophysiological mapping and radiofrequency ablation were completed using three-dimensional anatomical mapping system combined with three-dimensional intracardiac ultrasound technology.ECG and abaltion target diagram characteristics as well as the special anatomy were explored.Results All the 10 patients were successfully ablated and followed up for 12 months.One patient had recurrence within 12 months and no complications were recorded.The target sites localized at the tip (n =1),middle portion(n =4)or the base (n =5) of the LV-APM.Among 7 patients,the target sites were located at the anterior septal papillary muscle and in 3 patients were located in the free papillary muscle.9 patients were successfully ablated via anterograde trans-septal catheterization after the failure of retrograde approach.Premature QRS wave time were 152.80 ± 11.72 ms and 6 patients presented sharp potential at the targets during PVC/VT.Conclusions PVC/VT originating from left ventricle anterior papillary muscles have similar ECG and diagram characteristics that is different from which originating from left anterior fascicle.It is recommended to get the target via transseptalpuncure approach.Ablation target could be clearly positioned by three-dimensional intracardiac ultrasound technology.
8.Different strategies for the ablation of atrial tachycardia in the redo ablation of persistent atrial fibrillation
Xueyuan GUO ; Jianzeng DONG ; Deyong LONG ; Ronghui YU ; Ribo TANG ; Rong BAI ; Nian LIU ; Caihua SANG ; Chenxi JIANG ; Songnan LI ; Changsheng MA
Chinese Journal of Interventional Cardiology 2017;25(8):437-441
Objective The recurrence of perimitral atrial tachycardia is common after initial ablation of persistent atrial fibrillation (AF). The aim of the study is to explore a preferable ablation approach for perimitral atrial tachycardia in the redo ablation of persistent AF. Methods Seventy-four patients with perimitral atrial tachycardia after initial ablation for persistent AF were included in our study. Patients were distinguished into either the group of having ablation during tachycardia (Group A) or the group having ablation after cardioversion to sinus rhythm (Group B) according to the different ablation strategies. The procedural endpoints were pulmonary vein isolation and bidirectional conduction block of all the ablated lines. The primary endpoint of the study was freedom from atrial tachyarrhythmia recurrence during the follow-up period. Results There were statistical differences in baseline clinical data between the 2 groups. During the redo procedure, conduction recovery rate across the mitral isthmus (MI),cavotricuspid isthmus and left atial roofline were 100%, 40.5% and 48.6% respectively. The procedural time, fluoroscopy time, mapping time were longer in the patients of group A. During a mean follow-up of (16.9±6.3) months, 31 (72.1%) patients in group A and 21(67.7%) patients in group B maintained in sinus rhythm in the absence of antiarrhythmic durgs (P =0.771) . Conclusion In patients with perimitral atrial tachycardia after initial ablation for persistent AF,ablation in sinus rhythm is a more simplified method and as effective as ablation during tachycardia.
9.Impact of CHA2DS2 VASc score on substrate for persistent atrial fibrillation and outcome post catheter ablation of atrial fibrillation.
Tang RIBO ; Dong JIANZENG ; Liu XIAOHUI ; Shang MEISHENG ; Yu RONGHUI ; Long DEYONG ; Du XIN ; Kang JUNPING ; Wu JIAHUI ; Ning MAN ; Sang CAIHUA ; Jiang CHENXI ; Bai RONG ; Li SONGNAN ; Yao YAN ; Wen SONGNAN ; Ma CHANGSHENG
Chinese Journal of Cardiology 2015;43(8):695-699
OBJECTIVETo explore if CHA2DS2 VASc score can predict substrate for persistent atrial fibrillation ( AF) and outcome post catheter ablation of AF.
METHODSFrom January 2011 to December 2012,116 patients underwent catheter ablation of persistent AF in our department and were enrolled in this study. CHA2DS2VASc score was calculated as follows: two points were assigned for a history of stroke or transient ischemic attack and age ≥ 75 and 1 point each was assigned for age ≥ 65, a history of hypertension, diabetes,recent cardiac failure, vessel disease, female. Left atrial geometry ( LA) was reconstructed with a 3.5 mm tip ablation catheter with fill-in threshold 10 in CARTO system. The mapping catheter was stabled at each endocardial location for at least 3 seconds for recording. The electrogram recordings at each endocardial location were analyzed with a custom software embedded in the CARTO mapping system. Interval confidence level (ICL) was used to characterize complex fractionated atrial electrograms (CFAEs) . As the default setting of the software, ICL more than or equal to 7 was considered sites with a highly repetitive CFAEs complex. CFAEs index was defined as the fraction of area of ICL more than or equal to 7 to the left atrial surface. The CFAEs index and outcome of catheter ablation among different CHA2DS2VASc groups were compared.
RESULTSOf the 116 patients, CHA2DS2VASc was 0 in 33 patients, 1 in 31 patients and ≥ 2 in 52 patients. Left atrial surface ((121.2 ± 18.9) cm2, (133.6 ± 23.8) cm2, (133.9 ± 16.1) cm2, P = 0.008), left atrial volume ((103.6 ± 24.8) ml, (118.3 ± 27.8) ml, (120.9 ± 20.9) ml, P = 0.005) and CFAEs index (44.6% ± 22.4%, 54.2% ± 22.2%, 58.7% ± 23.1%, P = 0.023) increased in proportion with increasing CHA2DS2VASc. ICLmax, ICLmin and CFAEs spatial distribution were similar among the three groups. During the mean follow-up of (13 ± 8) months, the recurrence rate were 36.4%, 35.5%, 55.8% among the three groups (P = 0.025).
CONCLUSIONA high CHA2DS2VASc score is associated with extensive AF substrate and higher recurrence rate post catheter ablation of persistent AF.
Aged ; Atrial Fibrillation ; Catheter Ablation ; Electrophysiologic Techniques, Cardiac ; Female ; Heart Atria ; Heart Failure ; Humans ; Hypertension ; Recurrence ; Stroke ; Treatment Outcome
10.Prophylactic atropine administration prevents vasovagal response induced by cryoballoon ablation in patients with atrial fibrillation
Caihua SANG ; Liping SUN ; Jianzeng DONG ; Rong BAI ; Songnan LI ; Deyong LONG ; Ronghui YU ; Ribo TANG ; Chenxi JIANG ; Nian LIU ; Xueyuan GUO ; Songnan WEN ; Man NING ; Xin DU ; Changsheng MA
Chinese Journal of Interventional Cardiology 2017;25(7):385-389
Objective Cryoballoon ablation of pulmonary vein (PV) ostia often induces a vagal response.This prospective study was designed to assess the effectiveness of prophylactic intravenous administration of atropine on hemodynamic impairment induced by cryoballoon ablation in patients with atrial fibrillation.Methods Twenty-five patients with paroxysmal atrial fibrillation undergoing cryoballoon ablation were prospectively enrolled and assigned to either the trial group on the control group.First twelve patients (the trial group) were administered 1 mg of atropine before deflation of the cryoballoon,while the following 13 patients (the control group) were given atropine only after the onset of the hemodynamic variation (decrease in heart rate and/or blood pressure).Treatment was considered effective when the hemodynamic variations were restored.Results In the trial group,three patients with transient hypotension did not require further supportive care throughout the procedures and one patient with hypotension required supportive management.In the control group,hypotension,bradycardia and mixed bradycardia with hypotension requiring supportive care occurred in six,three,and three patients,respectively.Overall,the rate of marked vagal responses was significantly lower when prophylactic atropine was administrated (4/12 vs.12/13 patients,P < 0.01).Conclusions Atropine is effective in the prevention of all types of vasovagal responses induced by cryoballoon ablation in patients with atrial fibrillation.