1.Anatomical Courses of Lateral Antebrachial and Medial Antebrachial Cutaneous Nerves: A Cadaveric Study
Ye Ji KWON ; Jae Gyum KIM ; Dasom KIM ; Im Joo RHYU ; Byung Jo KIM
Journal of Clinical Neurology 2019;15(3):413-414
No abstract available.
Cadaver
2.Anatomical variations of the Celiac trunk in adult Filipino cadavers: A retrospective study
Karen June P. Dumlao ; Pio Renato F. Villacorta ; Olivia Agnes D. Mejia
Acta Medica Philippina 2020;54(Online):1-5
Objectives:
The celiac trunk (CT) is the first major branch of the abdominal aorta and typically gives rise to the left gastric artery (LGA), common hepatic artery (CHA), and splenic artery (SA), which supply blood to the abdominal viscera. Variations in the branching pattern of the CT exist and knowledge of such is crucial when performing surgical, laparoscopic, and angiographic procedures. The aim of this study is to determine the anatomic variations of the CT in adult Filipino cadavers and to compare the proportions of these with those reported in the foreign literature.
Methods:
Adult Filipino cadavers from the University of the Philippines College of Medicine Anatomy Laboratory were dissected by first year medical students from 2014-2019. The CT and its branches were identified, drawn on a separate piece of paper, and confirmed to be correct and accurate by an anatomist. The data collected from that period was reviewed. Percentages were calculated for the branching patterns identified. A Z-test of Two Populations was used to compare the results of the current study to that of Pinal-Garcia (2018), Pillay (2020) and Venieratos (2013).
Results:
A total of 107 drawings based on 107 dissected preserved cadavers were reviewed. Ninety-two specimens (85.98%) showed typical branching into the LGA, CHA, and SA. The CT presented as a true tripod (tripus Halleri) in 75 specimens (70.09%) and as a bifurcation with one of the three arteries arising first along the trunk (false tripod) in 17 specimens (15.89%). Nine cadavers (8.41%) showed additional branches arising from the CT and four (3.74%) showed bifurcation of the CT with the third branch arising from a different artery.
Conclusion
The most common configuration of the CT among Filipino adult cadavers is a true tripod, followed by a false tripod, additional branching, and bifurcation of the CT with the third branch arising elsewhere. The present study most closely resembles the results of the study of Venieratos.
Cadaver
3.Measurement of Normal Calcaneus in Korean Cadavers: A Preliminary Report.
Jung Han KIM ; Heui Chul GWAK ; Jeon Gyo KIM ; Yang Hwan JUNG
Journal of Korean Foot and Ankle Society 2014;18(1):14-18
PURPOSE: The purpose of this report is to evaluate the measured values of normal Korean calcaneus by conduct of a cadaveric study. MATERIALS AND METHODS: A total of 42 calcanei were obtained from Korean cadavers. A digital goniometer was used for measurement of Bohler's angle, Gissane angle, posterior facet articular inclination angle, and Fowler-Philip angle of calcaneus. A vernier caliper was used for measurement of the maximal antero-posterior length, maximal transverse width, and maximal height of calcaneus. RESULTS: The average Bohler's angle, Gissane angle, posterior facet articular inclination angle, and Fowler-Philip angle was 32.3degrees+/-5.0degrees, 114.4degrees+/-8.2degrees, 61.2degrees+/-4.4degrees, and 60.3degrees+/-7.6degrees. The average maximal antero-posterior length, maximal transverse width, and maximal height of calcaneus was 74.2+/-3.0 mm, 43.0+/-4.0 mm, and 42.5+/-3.0 mm. CONCLUSION: The measured values of normal Korean calcaneus were lower than the values reported in the international literature. Therefore, development of appropriate instruments reflecting the anatomical characteristics of Koreans will be needed.
Cadaver*
;
Calcaneus*
4.Experiences of first year medical students from their teachers beyond the grave
Remigio Jay-Ar Z. Butacan IV ; Leopoldo P. Sison Jr. ; Jose Luisito A. Zulueta ; Ma. Cristina E. Zulueta
Health Sciences Journal 2017;6(1):1-6
Introduction:
Dissecting cadavers to study Human Anatomy is an integral part of first year medical education. The aim of this study was to describe the experiences of the first year medical students during their first day of cadaver dissection.
Methods:
This study analyzed interviews of three first year medical students, chosen via purposive
sampling, who were present during the first day of cadaver dissection in gross anatomy. Interviews
were transcribed and analyzed through a Husserlian descriptive phenomenological approach.
Results :
Five common themes were identified: 1) fear of the unknown, 2) group dynamics, 3) sense
of awe and amazement of the cadaver's body, 4) respect for the body, and 5) taming of death as a rite
of passage to being a doctor.
Conclusion
Of the five emergent themes, taming death as a rite of passage to being a doctor is the
essence of the experiences of the first year medical students during the first day of cadaver
dissection.
Cadaver
;
Anatomy
5.An analysis of 15 cases of cadaveric kidney transplantation.
Jin Young KWAK ; Chan Dae PARK ; Kwang Soo LEE ; Chi Kyoo WON ; Jong Myung KANG ; Han Chul PARK ; Tchun Yong LEE ; Young Nam WOO
The Journal of the Korean Society for Transplantation 1993;7(1):119-127
No abstract available.
Cadaver*
;
Kidney Transplantation*
;
Kidney*
6.Primary stability of implants in ilium of cadaver by the methods of recipient site preparation.
Jung Woo SIM ; Jin Yong CHO ; Min Suk KOOK ; Hong Ju PARK ; Hee Kyun OH
Journal of the Korean Association of Oral and Maxillofacial Surgeons 2008;34(2):180-186
PURPOSE: This study was performed to evaluate the effect of the implant recipient site preparation methods on primary stability of implants with the instruments of Osstell(TM) and Periotest(R) in the iliac bone of cadaver. METHODS AND MATERIALS: The 8 iliac bones in 4 cadavers and implants treated with resorbable blasting media (RBM) were used. Periotest(R) (Simens AG, Germany) and Osstell(TM)(Model 6 Resonance Frequency Analyser: Integration Diagnostics Ltd., Sweden) were used to measure primary stability of implants. Implants were inserted into the iliac crest of the cadaver. In control group, the recipient site was prepared according to the manufacturer's recommendation: 1.8 mm guide drill, 2.0 mm initial drill, 2.7 mm pilot drill, 2.7 mm twist drill, 3.0 mm twist drill, 3.3 mm pilot drill, 3.3 mm twist drill, and 3.3 mm countersink drill as well as tapping drill were used in order. In the group 1, implant recipient sites were prepared by sequentially drilling from 1.8 mm guide drill to 3.0 mm twist drill and then inserted implants without countersinking and tapping. In the group 2, implant recipient sites were prepared to 3.0 mm twist drill and countersink drill and then inserted implants without tapping. In the group 3, the sites were prepared to 3.0 mm twist drill and countersink drill as well as tapping drill. In the group 4, the sites were prepared to 3.3 mm twist drill. In the group 5, the sites were prepared to 3.3 mm twist drill and countersink drill. A total of 60 implants were placed (n=10). The stability was measured using Osstell(TM) and Periotest(R) mesiodistally and buccolingually. To compare the mean stability of each group statistically, One-way ANOVA was used and correlation of instrument were analyzed using SPSS 12.0. The results obtained were as follows; 1. The stability of group 1 measured using Osstell(TM) and Periotest(R) buccolingually showed the highest, and there are significant difference statistically between control group and experimental group 1,2,4 in each instruments respectively (P<0.05). 2. The stability of group 1 measured using Osstell(TM) and Periotest(R) mesiodistally showed the highest. There are significant difference statistically between control group and all experimental groups in Osstell(TM), and between control group and experimental group 1,2,3,4 (P<0.05). 3. There are high correlation between the measurements of Osstell(TM) and Periotest(R) (P<0.05). CONCLUSION: These results indicate that the primary stability of implant can be obtained by the recipient sites preparation with smaller diameter drill than that of implant or minimal drilling.
Cadaver
;
Ilium
;
Mandrillus
7.Primary stability of implants in ilium of cadaver by the methods of recipient site preparation.
Jung Woo SIM ; Jin Yong CHO ; Min Suk KOOK ; Hong Ju PARK ; Hee Kyun OH
Journal of the Korean Association of Oral and Maxillofacial Surgeons 2008;34(2):180-186
PURPOSE: This study was performed to evaluate the effect of the implant recipient site preparation methods on primary stability of implants with the instruments of Osstell(TM) and Periotest(R) in the iliac bone of cadaver. METHODS AND MATERIALS: The 8 iliac bones in 4 cadavers and implants treated with resorbable blasting media (RBM) were used. Periotest(R) (Simens AG, Germany) and Osstell(TM)(Model 6 Resonance Frequency Analyser: Integration Diagnostics Ltd., Sweden) were used to measure primary stability of implants. Implants were inserted into the iliac crest of the cadaver. In control group, the recipient site was prepared according to the manufacturer's recommendation: 1.8 mm guide drill, 2.0 mm initial drill, 2.7 mm pilot drill, 2.7 mm twist drill, 3.0 mm twist drill, 3.3 mm pilot drill, 3.3 mm twist drill, and 3.3 mm countersink drill as well as tapping drill were used in order. In the group 1, implant recipient sites were prepared by sequentially drilling from 1.8 mm guide drill to 3.0 mm twist drill and then inserted implants without countersinking and tapping. In the group 2, implant recipient sites were prepared to 3.0 mm twist drill and countersink drill and then inserted implants without tapping. In the group 3, the sites were prepared to 3.0 mm twist drill and countersink drill as well as tapping drill. In the group 4, the sites were prepared to 3.3 mm twist drill. In the group 5, the sites were prepared to 3.3 mm twist drill and countersink drill. A total of 60 implants were placed (n=10). The stability was measured using Osstell(TM) and Periotest(R) mesiodistally and buccolingually. To compare the mean stability of each group statistically, One-way ANOVA was used and correlation of instrument were analyzed using SPSS 12.0. The results obtained were as follows; 1. The stability of group 1 measured using Osstell(TM) and Periotest(R) buccolingually showed the highest, and there are significant difference statistically between control group and experimental group 1,2,4 in each instruments respectively (P<0.05). 2. The stability of group 1 measured using Osstell(TM) and Periotest(R) mesiodistally showed the highest. There are significant difference statistically between control group and all experimental groups in Osstell(TM), and between control group and experimental group 1,2,3,4 (P<0.05). 3. There are high correlation between the measurements of Osstell(TM) and Periotest(R) (P<0.05). CONCLUSION: These results indicate that the primary stability of implant can be obtained by the recipient sites preparation with smaller diameter drill than that of implant or minimal drilling.
Cadaver
;
Ilium
;
Mandrillus
8.The Correlations Between Landmark of Inferior Oblique Muscle Recession and Adjacent Globe Structures.
Dae Hong KIM ; Seung Hyuck LEE ; Jong Bok LEE ; In Hyuk CHUNG
Journal of the Korean Ophthalmological Society 2002;43(8):1528-1535
PURPOSE: This study aimed to find out whether there are relationships among anatomic characteristics of inferior oblique muscle insertion, corneal diameter, axial length and inferior oblique recession landmark. METHODS: Thirty-one Korean cadaver orbits were dissected to expose the full length of extraocular muscles and sclera, and then we measured the length from the recession landmark of inferior oblique to the lateral edge of insertion of inferior rectus and to the inferior edge of insertion of lateral rectus. RESULTS: The mean of angles between the inferior oblique muscle insertion and lateral rectus direction is 27.9+/-9.0degrees and the range is from 15 degrees to 50 degrees . There is a statistically significant correlation between cord length of 8 mm recession landmark of inferior oblique and angles of inferior oblique insertion with lateral rectus direction. We divided the shapes of inferior oblique insertion into straight and convexed curves. Twelve insertions are straight and thirteen insertions are curved. There is no statistically significant correlation between shape of inferior oblique insertion and cord length from recession landmark. In corneal diameter and axial length, we found correlations with cord length of 8 mm and 10 mm recession landmark of inferior oblique. CONCLUSIONS: We conclud that there are some correlations among anatomic characteristics, axial length and corneal diameter with recession landmark of inferior oblique.
Cadaver
;
Muscles
;
Orbit
;
Sclera
9.Biomechanical Evaluation of the Pullout Strength of the Dynamic Osteosynthesis Construct(DOC) Anterior Cervical Plating System: A Comparison between the Screw Angulations to Consider the Concept of Triangulation.
Journal of Korean Neurosurgical Society 2004;36(1):52-58
OBJECTIVE: The aim of this study is to biomechanically assess the pullout strength of the dynamic osteosynthesis construct(DOC) cervical plating system to consider the effects of screw triagulation in the cervical spine. METHODS: Twelve fresh cadaveric cervical spines(C4-C7) were randomly instumented with DOC cervical system with 20 degree(six specimens) or 30 degree platforms(six specimens). All specimens were tested on an MTS Alliance RT/10 testing machine. Load-displacement data was sampled at a rate of 50Hz. After the biomechanical testing, specimens were cut on sagittal plane and the penetrating depths of screw were measured. RESULTS: Mean insertion torque of 20 degree was 1.025 newton-meters and that of 30 degree was 1.031 newton-meters(p>0.05). Mean penetration depth of 20 degree was 11.82mm(C4), 12.20mm(C7) and that of 30 degree platforms were 12.22mm(C4), 13.04mm(C7). Mean pullout strength with 20 degree platforms was 642.2 N ; with 30 degree platforms was 537.7N(p>0.05). CONCLUSION: There is no statistical differences in pullout strength between 20 degree platform and 30 degree platform that were plated in cervical vertebral bodies, even though a literature shows that more increased screw angulation of 30 degree than that of 20 degree would decrease pullout resistance due to less amount of bone purchase against the pullout force in parallelogram shaped cervical vertebral body.
Cadaver
;
Spine
;
Torque
10.Anatomy of the Alar Lobule in Korean Nose.
Hyun CHANG ; Seung Kyu HAN ; Sang Bum KIM ; Woo Kyung KIM
Journal of the Korean Society of Plastic and Reconstructive Surgeons 2006;33(3):269-275
This study is to provide details of the unique anatomical features on the alar lobule region in Korean nose. We hypothesized that the anatomy of this area differs according to the shape of the alar lobule. Based on the prominence and roundness of alar lobules, they were classified into horizontal and vertical types. A total of 20 fresh cadaver noses(10 for each type) were dissected. The anatomical differences between the horizontal and vertical types were investigated by gross and histologic studies. The alar lobule is composed of three layers, i.e., external skin, muscle, and vestibular skin. Profound differences between the two alar lobule types were evident in terms of the volume of the dilator naris anterior muscle, the insertion of the dilator naris posterior muscle, and the thickness of the external skin at the lateral end of the alar circumference. The horizontal type has a greater volume of dilator naris anterior muscle, an additional insertion of the dilator naris posterior muscle, and thicker external skin at the lateral end of the alar circumference than the vertical type. The Korean nose differs anatomically and morphologically from the Caucasian nose. This study shows that there are anatomic differences between the horizontal and vertical types of alar lobules in Korean nose.
Cadaver
;
Nose*
;
Skin