1.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
2.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
3.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
4.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
5.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
6.Prospective Comparative Evaluation of the Xpert MTB/RIF and Xpert MTB/RIF Ultra Assays for Detecting Mycobacterium tuberculosis and Rifampin Resistance in High-resource, Intermediate-burden Settings
Eunsang SUH ; Sangsoo JUNG ; Jun-Ki LEE ; Byung Woo JHUN ; Tae Yeul KIM ; Hee Jae HUH ; Nam Yong LEE
Annals of Laboratory Medicine 2025;45(6):583-590
Background:
The Xpert MTB/RIF Ultra (Xpert Ultra) was introduced to enhance the sensitivity of tuberculosis detection, particularly in smear-negative cases, compared with its predecessor, Xpert MTB/RIF (Xpert). However, its performance in high-resource, intermediateburden settings remains unassessed. We prospectively compared the diagnostic accuracy of Xpert Ultra and Xpert for detecting Mycobacterium tuberculosis (MTB) and rifampin resistance in Korea.
Methods:
In total, 309 respiratory specimens were analyzed using both assays. We used two reference standards: mycobacterial culture and a composite reference standard based on clinical diagnosis and treatment decisions. Diagnostic performance, including sensitivity, specificity, and agreement between the two assays, was assessed. Spiking experiments using 13 MTB isolates with known rpoB mutations were performed to evaluate rifampin resistance detection.
Results:
Xpert Ultra showed increased, albeit not significantly, sensitivity (73.7% vs. 65.8% with culture; 63.8% vs. 53.2% with the composite reference standard) over Xpert. Its specificity was comparable to that of Xpert; however, a few false-positive results were observed among trace- and very low-positives. Among six culture-negative but Xpert Ultra-positive cases, two were clinically diagnosed as tuberculosis. Of the 13 rpoB mutant strains, Xpert correctly detected all mutations in the rifampin resistance-determining region, whereas Xpert Ultra yielded indeterminate results for Q432P and Q429H/L430P/H445Q.
Conclusions
Xpert Ultra tends to have increased sensitivity; however, it shows potential diagnostic ambiguity associated with trace- or very low-positive results. These findings highlight the importance of clinical correlation, particularly in culture-negative cases. Indeterminate results in certain rpoB mutations require cautious interpretation.
7.Clinical Trial Protocol for Porcine Islet Xenotransplantation in South Korea
Byung-Joon KIM ; Jun-Seop SHIN ; Byoung-Hoon MIN ; Jong-Min KIM ; Chung-Gyu PARK ; Hee-Jung KANG ; Eung Soo HWANG ; Won-Woo LEE ; Jung-Sik KIM ; Hyun Je KIM ; Iov KWON ; Jae Sung KIM ; Geun Soo KIM ; Joonho MOON ; Du Yeon SHIN ; Bumrae CHO ; Heung-Mo YANG ; Sung Joo KIM ; Kwang-Won KIM
Diabetes & Metabolism Journal 2024;48(6):1160-1168
Background:
Islet transplantation holds promise for treating selected type 1 diabetes mellitus patients, yet the scarcity of human donor organs impedes widespread adoption. Porcine islets, deemed a viable alternative, recently demonstrated successful longterm survival without zoonotic risks in a clinically relevant pig-to-non-human primate islet transplantation model. This success prompted the development of a clinical trial protocol for porcine islet xenotransplantation in humans.
Methods:
A single-center, open-label clinical trial initiated by the sponsor will assess the safety and efficacy of porcine islet transplantation for diabetes patients at Gachon Hospital. The protocol received approval from the Gachon Hospital Institutional Review Board (IRB) and the Korean Ministry of Food and Drug Safety (MFDS) under the Investigational New Drug (IND) process. Two diabetic patients, experiencing inadequate glycemic control despite intensive insulin treatment and frequent hypoglycemic unawareness, will be enrolled. Participants and their family members will engage in deliberation before xenotransplantation during the screening period. Each patient will receive islets isolated from designated pathogen-free pigs. Immunosuppressants and systemic infection prophylaxis will follow the program schedule. The primary endpoint is to confirm the safety of porcine islets in patients, and the secondary endpoint is to assess whether porcine islets can reduce insulin dose and the frequency of hypoglycemic unawareness.
Conclusion
A clinical trial protocol adhering to global consensus guidelines for porcine islet xenotransplantation is presented, facilitating streamlined implementation of comparable human trials worldwide.
8.Correction: 2023 Korean Society of Echocardiography position paper for diagnosis and management of valvular heart disease, part I: aortic valve disease
Sun Hwa LEE ; Se Jung YOON ; Byung Joo SUN ; Hyue Mee KIM ; Hyung Yoon KIM ; Sahmin LEE ; Chi Young SHIM ; Eun Kyoung KIM ; Dong Hyuk CHO ; Jun Bean PARK ; Jeong Sook SEO ; Jung Woo SON ; In Cheol KIM ; Sang Hyun LEE ; Ran HEO ; Hyun Jung LEE ; Jae Hyeong PARK ; Jong Min SONG ; Sang Chol LEE ; Hyungseop KIM ; Duk Hyun KANG ; Jong Won HA ; Kye Hun KIM ;
Journal of Cardiovascular Imaging 2024;32(1):34-
9.Contemporary diagnosis and treatment of valvular heart disease in Korea: a nationwide hospital‑based registry study
Hyung Yoon KIM ; Hee Jeong LEE ; In‑Cheol KIM ; Jung‑Woo SON ; Jun‑Bean PARK ; Sahmin LEE ; Eun Kyoung KIM ; Seong‑Mi PARK ; Woo‑Baek CHUNG ; Jung Sun CHO ; Jin‑Sun PARK ; Jeong‑Sook SEO ; Sun Hwa LEE ; Byung Joo SUN ; Chi Young SHIM ; Hyungseop KIM ; Kye Hun KIM ; Duk‑Hyun KANG ; Jong‑Won HA ;
Journal of Cardiovascular Imaging 2024;32(1):37-
Background:
This study was designed to determine the current status of diagnosis and treatment of valvular heart disease (VHD) in Korea.
Methods:
A nationwide registry study was conducted in 45 hospitals in Korea involving adult patients with at least moderate VHD as determined by echocardiography carried out between September and October of 2019. Of a total of 4,094 patients with at least moderate VHD, 1,482 had severe VHD (age, 71.3 ± 13.5 years; 49.1% male). Echocar‑ diographic data used for the diagnosis of each case of VHD were analyzed. Experts from each center determined the diagnosis and treatment strategy for VHD based on current guidelines and institutional policy. The clinical out‑ come was in-hospital mortality.
Results:
Each valve underwent surgical or transcatheter intervention in 19.3% cases of severe mitral stenosis, 31.4% cases of severe primary mitral regurgitation (MR), 7.5% cases of severe secondary MR, 43.7% cases of severe aortic stenosis, 27.5% cases of severe aortic regurgitation, and 7.2% cases of severe tricuspid regurgitation. The overall inhospital mortality rate for patients with severe VHD was 5.4%, and for secondary severe MR and severe tricuspid regur‑ gitation, the rates were 9.0% and 7.5%, respectively, indicating a poor prognosis. In-hospital mortality occurred in 73 of the 1,244 patients (5.9%) who received conservative treatment and in 18 of the 455 patients (4.0%) who received a surgical or transcatheter intervention, which was significantly lower in the intervention group (P = 0.037).
Conclusions
This study provides important information about the current status of VHD diagnosis and treatment through a nationwide registry in Korea and helps to define future changes.
10.Blood Pressure Variability and Ocular Vestibular-Evoked Myogenic Potentials Are Independently Associated With Orthostatic Hypotension
Keun-Tae KIM ; Jeong-Heon LEE ; Jun-Pyo HONG ; Jin-Woo PARK ; Sun-Uk LEE ; Euyhyun PARK ; Byung-Jo KIM ; Ji-Soo KIM
Journal of Clinical Neurology 2024;20(6):571-579
Background:
and Purpose We delineated the association between otolithic dysfunction and blood pressure (BP) variability.
Methods:
We prospectively recruited 145 consecutive patients (age=71 [59–79] years, median [interquartile range]; 76 females) with orthostatic intolerance between December 2021 and December 2023 at a tertiary hospital in South Korea. Each patient underwent evaluations of cervical and ocular vestibular-evoked myogenic potentials (oVEMPs), 24-h noninvasive ambulatory BP monitoring (ABPM), and a head-up tilt-table test using the Finometer device. As measures of BP variability, the standard deviations (SDs) of the systolic BP (SBP SD) and the diastolic BP were calculated based on serial ABPM recordings. Patients were divided into those with orthostatic hypotension (OH, n=68) and those with a normal head-up tilt-table test despite orthostatic intolerance (NOI, n=77) groups.
Results:
A multivariable logistic regression analysis showed that OH was associated with bilateral oVEMP abnormalities (p=0.021), SBP SD (p=0.012), and female sex (p=0.004). SBP SD was higher in patients with OH than in those with NOI (p<0.001), and was not correlated with n1–p1 amplitude (p=0.491) or normalized p13–n23 amplitude (p=0.193) in patients with OH.The sensitivity and specificity for differentiating OH from NOI were 72.1% and 67.5%, respectively, at a cutoff value of 12.7 mm Hg for SBP SD, with an area under the receiver operating characteristic curve of 0.73.
Conclusions
Bilaterally deficient oVEMP responses may be associated with OH regardless of 24-h BP variability, reflecting the integrity of the otolith-autonomic reflex during orthostasis. Alternatively, 24-h BP variability is predominantly regulated by the baroreflex, which also participates in securing orthostatic tolerance complementary to the vestibulo-autonomic reflex.

Result Analysis