1.Proton pump inhibitor intake negatively affects the osseointegration of dental implants: a retrospective study
Mehmet Ali ALTAY ; Alper SINDEL ; Oznur ÖZALP ; Nelli YıLDıRıMYAN ; Burak KOCABALKAN
Journal of the Korean Association of Oral and Maxillofacial Surgeons 2019;45(3):135-140
OBJECTIVES:
This study sought to investigate the association between the systemic intake of proton pump inhibitors (PPI) and the early failure of dental implants.
MATERIALS AND METHODS:
A retrospective cohort study involving 1,918 dental implants in 592 patients (69 implants in 24 PPI users and 1,849 implants in 568 nonusers, respectively) was conducted. The effect of PPI intake on the osseointegration of dental implants was evaluated using patient- and implant-level models.
RESULTS:
Among 24 PPI users, two patients experienced implant failure, one of whom had three and the other of whom had one failed implant, respectively. Thus, the rate of failure for this population was 8.3%. Separately, 11 nonusers each experienced one implant failure, and the failure rate for these patients was 1.9%. Fisher's exact test revealed statistically significant differences between PPI users and nonusers at the implant level (P=0.002) but failed to show any significance at the patient level (P=0.094). The odds of implant failure were 4.60 times greater among PPI users versus nonusers. Dental implants that were placed in patients using PPIs were found to be 4.30 times more likely to fail prior to loading.
CONCLUSION
The findings of this study suggest that PPI intake may be associated with an increased risk of early dental implant failure.
2.Proton pump inhibitor intake negatively affects the osseointegration of dental implants: a retrospective study
Mehmet Ali ALTAY ; Alper SINDEL ; Oznur ÖZALP ; Nelli YILDIRIMYAN ; Burak KOCABALKAN
Journal of the Korean Association of Oral and Maxillofacial Surgeons 2019;45(3):135-140
OBJECTIVES: This study sought to investigate the association between the systemic intake of proton pump inhibitors (PPI) and the early failure of dental implants. MATERIALS AND METHODS: A retrospective cohort study involving 1,918 dental implants in 592 patients (69 implants in 24 PPI users and 1,849 implants in 568 nonusers, respectively) was conducted. The effect of PPI intake on the osseointegration of dental implants was evaluated using patient- and implant-level models. RESULTS: Among 24 PPI users, two patients experienced implant failure, one of whom had three and the other of whom had one failed implant, respectively. Thus, the rate of failure for this population was 8.3%. Separately, 11 nonusers each experienced one implant failure, and the failure rate for these patients was 1.9%. Fisher's exact test revealed statistically significant differences between PPI users and nonusers at the implant level (P=0.002) but failed to show any significance at the patient level (P=0.094). The odds of implant failure were 4.60 times greater among PPI users versus nonusers. Dental implants that were placed in patients using PPIs were found to be 4.30 times more likely to fail prior to loading. CONCLUSION: The findings of this study suggest that PPI intake may be associated with an increased risk of early dental implant failure.
Cohort Studies
;
Dental Implantation
;
Dental Implants
;
Humans
;
Morinda
;
Osseointegration
;
Proton Pump Inhibitors
;
Proton Pumps
;
Protons
;
Rehabilitation
;
Retrospective Studies
;
Risk Factors
3.Comparing the precision of panoramic radiography and cone-beam computed tomography in avoiding anatomical structures critical to dental implant surgery: A retrospective study
Oznur ÖZALP ; Hüseyin Alican TEZERIŞENER ; Burak KOCABALKAN ; Ulviye Sebnem BÜYÜKKAPLAN ; Mehmet Mustafa ÖZARSLAN ; Göksel ŞIMŞEK KAYA ; Mehmet Ali ALTAY ; Alper SINDEL
Imaging Science in Dentistry 2018;48(4):269-275
PURPOSE: The aim of this study was to evaluate the correlations between measurements made using panoramic radiography and cone-beam computed tomography (CBCT) based on certain anatomical landmarks of the jaws, with the goal of preventing complications due to inaccurate measurements in the pre-surgical planning phase of dental implant placement. MATERIALS AND METHODS: A total of 56 individuals who underwent panoramic radiography and a CBCT evaluation before dental implant surgery were enrolled in the study. Measurements were performed to identify the shortest vertical distance between the alveolar crest and neighboring anatomical structures, including the maxillary sinus, nasal floor, mandibular canal, and foramen mentale. The differences between the measurements on panoramic radiography and CBCT images were statistically analyzed. RESULTS: Statistically significant differences were observed between the measurements on panoramic radiography and CBCT for all anatomical structures (P < .05). The correlation coefficients (r) between the paired samples obtained from panoramic radiography and CBCT were closely correlated (P < .05), with r values varying from 0.921 and 0.979 for different anatomical regions. CONCLUSION: The results of this study support the idea that panoramic radiography might provide sufficient information on bone height for preoperative implant planning in routine cases or when CBCT is unavailable. However, an additional CBCT evaluation might be helpful in cases where a safety margin cannot be respected due to insufficient bone height.
Cone-Beam Computed Tomography
;
Dental Implants
;
Jaw
;
Maxillary Sinus
;
Radiography, Panoramic
;
Retrospective Studies