1.Bibliometric analysis of doctor-nurse integration mode in China
Modern Clinical Nursing 2018;17(4):56-60
Objective To analyze the current status and development tendency of doctor-nurse integration mode in China. Methods Toally 312 research papers with regard to doctor-nurse integration mode published in CJFD database from Mainland China were obtained and analyzed from each distribution in terms of year,journal,area,writer,organization,theme,fund support and research object. Results Since the concept of doctor-nurse mode was introduced into clinical practice in 2011, correlation studies showed an increasing trend year by year. Relevant literature in this study was published from the 136 medical journals and 28 provinces in Mainland China, with the theme focusing on the clinical nursing research. Guangdong Province, Sichuan Province and Chongqing City were on the top three. 33 (10.58%) of the researches were sponsored with provincial and national funds. Conclusions As a new mode in the medical care management, doctor-nurse integration mode becomes more and more popular in clinical practice and shows an increasing trend in research and application. However, the quality of clinical research is still at a low level. More multi-centered, high quality, randomized controlled trials are needed. Moreover, management standard and specification of this field have not been regulated in China.
2.Application of telemedicine robot in follow-up after liver transplantation from donation after cardiac death
Boyan TIAN ; Huapeng LU ; Jiaoqiong ZHANG ; Hongfan DING ; Wenyuan LIU ; Min TIAN ; Yi LYU ; Qinling YANG
Organ Transplantation 2019;10(1):79-
Objective To evaluate the application effect of telemedicine robot on the postoperative follow-up of liver transplantation recipients from donation after cardiac death (DCD). Methods A total of 100 recipients undergoing liver transplantation from DCD in the First Affiliated Hospital of Xi 'an Jiaotong University from January 2014 to December 2017 were recruited in this investigation. According to differnt follow-up patterns, all recipients were divided into the research group (
3.Visualization analysis of literature information in Organ Transplantation from 2010 to 2019 based on information metrology
Huapeng LU ; Qinling YANG ; Yi LYU ; Dinghui DONG ; Boyan TIAN ; Wenjun TAN ; Wenjie TIAN ; Xia XIN ; Xuemei ZHENG
Organ Transplantation 2020;11(6):724-
Objective To analyze the characteristics of papers published in
4.Development of magnetic spiderman to optimize the procedures of repairment of donor liver from organ donation
Boyan TIAN ; Dinghui DONG ; Yue WANG ; Xuemin LIU ; Junxi XIANG ; Haoyang ZHU ; Yi LYU
Organ Transplantation 2018;9(3):200-204
Objective To develop a pulling device using magnetic positioning to optimize the procedures of repairment of donor liver from organ donation . Methods The pig liver specimens were used to measure the pull force of repairment of donor liver, magnetic spiderman was developed based on the measurement results. The magnetic spiderman was applied to simulate the repairment of donor liver from organ donation on the pig liver specimens. The effectiveness of magnetic spiderman was also evaluated. Results The pulling force was required all less than 2 N during the repairment of donor liver. The magnetic spiderman was successfully manufactured. The magnets of magnetic spiderman could generate 3 N magnetic forces with paramagnetic basin of hepatic repairment. The self-retraction pull wire of the magnetic spiderman could provide 2.5 N pulling forces. The magnetic spiderman was successfully applied to the simulated experiment of repairment of donor liver from organ donation in 6 cases. The operation time was (54±5) min. No clip slippage,displacement and slippage of the base occurred during the operation. With the cooperation of multiple magnetic spidermen,the remaining surgical procedures were performed by one single surgeon except for the vascular ligation. Conclusions The magnetic spiderman has small volume and implements flexible positioning, can perform pulling operation and nottake up operational space. It can effectively optimize the procedures of repairment of donor liver from organ donation and reduce the quantity of surgeons.
5.Nursing cooperation for single-port laparoscopic cholecystectomy based on magnetic anchor technique
Boyan TIAN ; Miaomiao ZHANG ; Jianqi MAO ; Yi LYU ; Xiaopeng YAN
Journal of Clinical Medicine in Practice 2024;28(17):105-108,113
Objective To explore the key nursing cooperation points in single-port laparoscopic cholecystectomy based on magnetic anchor technique.Methods The general information of 24 pa-tients with transumbilical single-port laparoscopic cholecystectomy based on magnetic anchor tech-nique was analyzed.Combined with the surgical procedure,the key nursing cooperation points of this innovative surgery were analyzed from the perspective of operating room nurses.Results By learning the principles of magnetic anchor technique before surgery,understanding the usage and precautions of the magnetic anchor device,accurately passing the magnetic anchor device during surgery,and a-voiding mutual interference between the magnetic anchor device and conventional surgical instruments,the operating room nurses successfully assisted the surgeons in completing 24 cases of transumbilical single-port laparoscopic cholecystectomy based on magnetic anchor technique.Conclusion Real-time understanding of the surgeon's operation progress during surgery,accurate delivery of instruments,and avoidance of interference between the magnetic anchor device and conventional surgical instru-ments are important factors in the nursing cooperation of this surgical procedure.
6.Nursing cooperation for single-port laparoscopic cholecystectomy based on magnetic anchor technique
Boyan TIAN ; Miaomiao ZHANG ; Jianqi MAO ; Yi LYU ; Xiaopeng YAN
Journal of Clinical Medicine in Practice 2024;28(17):105-108,113
Objective To explore the key nursing cooperation points in single-port laparoscopic cholecystectomy based on magnetic anchor technique.Methods The general information of 24 pa-tients with transumbilical single-port laparoscopic cholecystectomy based on magnetic anchor tech-nique was analyzed.Combined with the surgical procedure,the key nursing cooperation points of this innovative surgery were analyzed from the perspective of operating room nurses.Results By learning the principles of magnetic anchor technique before surgery,understanding the usage and precautions of the magnetic anchor device,accurately passing the magnetic anchor device during surgery,and a-voiding mutual interference between the magnetic anchor device and conventional surgical instruments,the operating room nurses successfully assisted the surgeons in completing 24 cases of transumbilical single-port laparoscopic cholecystectomy based on magnetic anchor technique.Conclusion Real-time understanding of the surgeon's operation progress during surgery,accurate delivery of instruments,and avoidance of interference between the magnetic anchor device and conventional surgical instru-ments are important factors in the nursing cooperation of this surgical procedure.
7.Periodontitis exacerbates pulmonary hypertension by promoting IFNγ+T cell infiltration in mice
Meng XIAOQIAN ; Du LINJUAN ; Xu SHUO ; Zhou LUJUN ; Chen BOYAN ; Li YULIN ; Chen CHUMAO ; Ye HUILIN ; Zhang JUN ; Tian GUOCAI ; Bai XUEBING ; Dong TING ; Lin WENZHEN ; Sun MENGJUN ; Zhou KECONG ; Liu YAN ; Zhang WUCHANG ; Duan SHENGZHONG
International Journal of Oral Science 2024;16(2):359-369
Uncovering the risk factors of pulmonary hypertension and its mechanisms is crucial for the prevention and treatment of the disease.In the current study,we showed that experimental periodontitis,which was established by ligation of molars followed by orally smearing subgingival plaques from patients with periodontitis,exacerbated hypoxia-induced pulmonary hypertension in mice.Mechanistically,periodontitis dysregulated the pulmonary microbiota by promoting ectopic colonization and enrichment of oral bacteria in the lungs,contributing to pulmonary infiltration of interferon gamma positive(IFNγ+)T cells and aggravating the progression of pulmonary hypertension.In addition,we identified Prevotella zoogleoformans as the critical periodontitis-associated bacterium driving the exacerbation of pulmonary hypertension by periodontitis,and the exacerbation was potently ameliorated by both cervical lymph node excision and IFNγ neutralizing antibodies.Our study suggests a proof of concept that the combined prevention and treatment of periodontitis and pulmonary hypertension are necessary.
8.Optimization of preparation method of rectovaginal fistula animal model based on principle of magnetic compression technique
Boyan TIAN ; Miaomiao ZHANG ; Jianqi MAO ; Yi LYU ; Xiaopeng YAN
Chongqing Medicine 2024;53(12):1768-1771,1777
Objective To investigate the feasibility of the optimally designed"I"shaped structure mag-net based on the principle of magnetic compression technique for the preparation of rectovaginal fistula animal model.Methods Using 10 New Zealand female rabbits as the model animals,two self-designed magnets were inserted through the vagina and anus respectively after anesthesia,and the two magnets were adjusted to the appropriate position and made them attraction each other to form a magnet-rectovaginal partition-magnet structure.When the compression tissue between the magnets became ischemic necrosis and fell off,the two magnets formed the"1"shape structure and were located in the stoma of rectovaginal fistula to prevent the stoma from becoming smaller or even closing itself.The operation time and rectovaginal fistula formation time were recorded.The experimental rabbits were killed in postoperative 2 weeks,and the rectovaginal fistula specimens were obtained.The formation of fistula orifice was observed and the size of fistula orifice was meas-ured.Results The animal model of rectovaginal fistula was successfully prepared in all 10 experimental rab-bits.The procedure of intraoperative magnet placement was smooth and the operation time was(1.55±0.65)min.The experimental animals were generally in good condition after surgery,and the fistula orifice was formed on postoperative(4.80±0.75)d.After taking the gross specimen of rectovaginal septum in postopera-tive 2 weeks,the magnet was removed.The fistula orifice of rectovaginal fistula was visible with the diameter of(5.86±0.38)mm.Conclusion The"I"shaped structure magnet designed based on the principle of mag-netic compression technique could be used in the preparation of the rectovaginal fistula animal model.Its oper-ation is simple with high success rate of model preparation and good uniformity in fistula orifice.