2.Ovarian carcinoma presenting with isolated contralateral inguinal lymph node metastasis: a case report.
Daphne ANG ; Keng-Yeen NG ; Hak-Koon TAN ; Alexander Y F CHUNG ; Boon-Siang YEW ; Victor K M LEE
Annals of the Academy of Medicine, Singapore 2007;36(6):427-430
INTRODUCTIONOvarian carcinoma usually presents at an advanced stage with diffuse intraabdominal manifestations. We report a patient who presented with a right groin swelling.
CLINICAL PICTUREThe only clinical abnormality was an enlarged right inguinal lymph node (3 x 2 cm), for which excision biopsy revealed metastatic adenocarcinoma. A computed tomography (CT) scan showed an enlarged left ovarian lesion (9.0 x 6.4 cm).
TREATMENT AND OUTCOMELaparotomy with total hysterectomy, bilateral salpingo-oophrectomy and partial omentectomy were performed. Histology confirmed left ovarian adenocarcinoma, consistent with the earlier histology of the right inguinal lymph node. There were no other sites of involvement. Postoperatively, the patient received adjuvant chemotherapy for treatment of FIGO Stage IIIc ovarian carcinoma and is clinically disease free 13 months after surgery.
CONCLUSIONSOvarian cancer presenting with inguinal lymph node metastases is uncommon. Ovarian cancer which manifests solely as a contralateral inguinal lymph node metastasis has not been previously reported. This case illustrates a rare presentation of ovarian carcinoma, and underscores the need to consider ovarian carcinoma in the differential diagnosis of women with inguinal lymphadenopathy.
Adenocarcinoma ; pathology ; surgery ; Female ; Groin ; Humans ; Lymphatic Metastasis ; Middle Aged ; Ovarian Neoplasms ; diagnostic imaging ; pathology ; surgery ; Tomography, X-Ray Computed
3.Initial experience of subcutaneous implantable cardioverter defibrillators in Singapore: a case series and review of the literature.
Tien Siang Eric LIM ; Boon Yew TAN ; Kah Leng HO ; Chuh Yih Paul LIM ; Wee Siong TEO ; Chi-Keong CHING
Singapore medical journal 2015;56(10):580-585
Transvenous implantable cardioverter defibrillators are a type of implantable cardiac device. They are effective at reducing total and arrhythmic mortality in patients at risk of sudden cardiac death. Subcutaneous implantable cardioverter defibrillators (S-ICDs) are a new alternative that avoids the disadvantages of transvenous lead placement. In this case series, we report on the initial feasibility and safety of S-ICD implantation in Singapore.
Adult
;
Death, Sudden, Cardiac
;
prevention & control
;
Defibrillators, Implantable
;
statistics & numerical data
;
Electrophysiology
;
Follow-Up Studies
;
Humans
;
Male
;
Middle Aged
;
Patient Safety
;
Prosthesis Implantation
;
Singapore
;
Tachycardia, Ventricular
;
Ventricular Fibrillation
4.Remote monitoring of patients with cardiac implantable electronic devices: a Southeast Asian, single-centre pilot study.
Paul Chun Yih LIM ; Audry Shan Yin LEE ; Kelvin Chi Ming CHUA ; Eric Tien Siang LIM ; Daniel Thuan Tee CHONG ; Boon Yew TAN ; Kah Leng HO ; Wee Siong TEO ; Chi Keong CHING
Singapore medical journal 2016;57(7):372-377
INTRODUCTIONRemote monitoring of cardiac implantable electronic devices (CIED) has been shown to improve patient safety and reduce in-office visits. We report our experience with remote monitoring via the Medtronic CareLink(®) network.
METHODSPatients were followed up for six months with scheduled monthly remote monitoring transmissions in addition to routine in-office checks. The efficacy of remote monitoring was evaluated by recording compliance to transmissions, number of device alerts requiring intervention and time from transmission to review. Questionnaires were administered to evaluate the experiences of patients, physicians and medical technicians.
RESULTSA total of 57 patients were enrolled; 16 (28.1%) had permanent pacemakers, 34 (59.6%) had implantable cardioverter defibrillators and 7 (12.3%) had cardiac resynchronisation therapy defibrillators. Overall, of 334 remote transmissions scheduled, 73.7% were on time, 14.5% were overdue and 11.8% were missed. 84.6% of wireless transmissions were on time, compared to 53.8% of non-wireless transmissions. Among all transmissions, 4.4% contained alerts for which physicians were informed and only 1.8% required intervention. 98.6% of remote transmissions were reviewed by the second working day. 73.2% of patients preferred remote monitoring. Physicians agreed that remote transmissions provided information equivalent to in-office checks 97.1% of the time. 77.8% of medical technicians felt that remote monitoring would help the hospital improve patient management. No adverse events were reported.
CONCLUSIONRemote monitoring of CIED is safe and feasible. It has possible benefits to patient safety through earlier detection of arrhythmias or device malfunction, permitting earlier intervention. Wireless remote monitoring, in particular, may improve compliance to device monitoring. Patients may prefer remote monitoring due to possible improvements in quality of life.
Aged ; Arrhythmias, Cardiac ; diagnosis ; Defibrillators, Implantable ; Female ; Follow-Up Studies ; Humans ; Male ; Middle Aged ; Monitoring, Physiologic ; methods ; Pacemaker, Artificial ; Patient Safety ; Pilot Projects ; Prospective Studies ; Quality of Life ; Remote Consultation ; methods ; Singapore ; Surveys and Questionnaires
5.CPG UPDATE - Practical guide in using insulin degludec/insulin aspart: A multidisciplinary approach in Malaysia
Siew Pheng Chan ; Malik Mumtaz ; Jeyakantha Ratnasingam ; Alexander Tong Boon Tan ; Siang Chin Lim ; Azhari Rosman ; Kok Han Chee ; Soo Kun Lim ; Shiong Shiong Yew ; Barakatun-Nisak Mohd Yusof ; Bik Kui Lau ; Saiful Bahari Kassim ; Mafauzy Mohamed
Malaysian Family Physician 2023;18(All Issues):1-12
Insulin degludec/insulin aspart (IDegAsp) co-formulation provides both basal and mealtime glycaemic control in a single injection. The glucose level-lowering efficacy of IDegAsp is reported to be superior or non-inferior to that of the currently available insulin therapies with a lower rate of overall hypoglycaemia and nocturnal hypoglycaemia. An expert panel from Malaysia aims to provide insights into the utilisation of IDegAsp across a broad range of patients with type 2 diabetes mellitus (i.e. treatment-naïve or insulin-naïve patients or patients receiving treatment intensification from basal-only regimens, premixed insulin and basal–bolus insulin therapy). IDegAsp can be initiated as once-daily dosing for the main meal with the largest carbohydrate content with weekly dose adjustments based on patient response. A lower starting dose is recommended for patients with cardiac or renal comorbidities. Dose intensification with IDegAsp may warrant splitting into twice-daily dosing. IDegAsp twice-daily dosing does not need to be split at a 50:50 ratio but should be adjusted to match the carbohydrate content of meals. The treatment of patients choosing to fast during Ramadan should be switched to IDegAsp early before Ramadan, as a longer duration of titration leads to better glycated haemoglobin level reductions. The pre-Ramadan breakfast/lunch insulin dose can be reduced by 30%–50% and taken during sahur, while the pre-Ramadan dinner dose can be taken without any change during iftar. Education on the main meal concept is important, as carbohydrates are present in almost all meals. Patients should not have a misconception of consuming more carbohydrates while taking IDegAsp.
insulin degludec [Supplementary Concept]
;
Insulin Aspart
;
Glucose
;
Hypoglycaemia
;