1.FK506 immunosuppression for submandibular salivary gland allotransplantation in rabbit
Akram Abdo ALMANSOORI ; Namuun KHENTII ; Kyung Won JU ; Bongju KIM ; Soung Min KIM ; Jong-Ho LEE
Journal of the Korean Association of Oral and Maxillofacial Surgeons 2020;46(3):197-203
Objectives:
We compared the outcomes of two different doses of FK506 (tacrolimus) for immunosuppression in submandibular salivary gland (SMG) allotransplantation.
Materials and Methods:
Three SMG allotransplantation groups were established (n=6 per group) as follows: allograft rejection control (Allo-Ctrl), low dose (0.08 mg/kg) of FK506 (FK506-L), and high dose (0.16 mg/kg) of FK506 (FK506-H). Allograft survival and rejection were assessed by clinical observation, interleukin-2 levels as determined by enzyme-linked immunosorbent assay, blood sampling for complete blood count (CBC), and histological evaluation.
Results:
Body weight and anorexia were higher in the FK506-H group but without a significant difference compared with the FK506-L population. CBC revealed a non-significantly reduced number of changes in the FK506-L group. Four glands in the FK506-H group and two glands in the FK506- L group were viable and functioning post-transplantation.
Conclusion
The survival rate of allotransplanted glands was higher in conjunction with the high dose of 0.16 mg/kg of FK506, with no major difference in the side-effect profile when compared with the low dose of 0.08 mg/kg short-term outcomes.
2.Efficacy of Percutaneous Epidural Neuroplasty Does Not Correlate with Dural Sac Cross-Sectional Area in Single Level Disc Disease.
Gyu Yeul JI ; Chang Hyun OH ; Bongju MOON ; Seung Hyun CHOI ; Dong Ah SHIN ; Young Sul YOON ; Keung Nyun KIM
Yonsei Medical Journal 2015;56(3):691-697
PURPOSE: Percutaneous epidural neuroplasty (PEN) is a minimally invasive treatment. The efficacy of PEN has been relatively well investigated; however, the relationship between the clinical effectiveness of PEN and the severity of spinal canal stenosis by disc material has not yet been established. The purpose of this study was to compare clinical outcomes of PEN according to the dural sac cross-sectional area in single level disc disease. MATERIALS AND METHODS: This study included 363 patients with back pain from single level disc disease with and without radiculopathy. Patients were categorized into groups according to spinal canal compromise by disc material: Category 1, less or more than 50%; and Category 2, three subgroups with lesser than a third, between a third and two thirds, and more than two thirds. Clinical outcomes were assessed according to the Visual Analog Scale (VAS) score for back pain and leg pain and Odom's criteria at 1, 3, 6, 12, and 24 months after treatment. RESULTS: The demographic data showed no difference between groups according to spinal canal compromise by disc material except age (older age correlated with more spinal canal compromise). The dural sac cross-sectional area did not correlate with the VAS scores for back and leg pain after PEN in single level disc disease in Groups 1 and 2. Odom's criteria after PEN were also not different according to dural sac cross-sectional area by disc material. CONCLUSION: PEN is an effective procedure in treating single level lumbar disc herniation without affecting dural sac cross-sectional area.
Adult
;
Aged
;
Back Pain/etiology/*surgery
;
Dura Mater/*pathology
;
Female
;
Humans
;
Intervertebral Disc
;
Intervertebral Disc Displacement
;
Magnetic Resonance Imaging
;
Male
;
Middle Aged
;
Reconstructive Surgical Procedures
;
Spinal Stenosis/complications/*pathology
;
Tissue Adhesions/*surgery
;
Treatment Outcome
;
Visual Analog Scale
3.Questionnaire survey for the clinical trial participants who experienced both digital and conventional impression
Eunbee YANG ; Bongju KIM ; Jun Jae LEE ; Seung Pyo LEE ; Young Jun LIM
Journal of Dental Rehabilitation and Applied Science 2018;34(4):270-279
PURPOSE: The aim of this study was to assess the patients' perception, acceptance, and preference of the difference between a conventional impression and digital impression through questionnaire survey. MATERIALS AND METHODS: Thirteen (6 male, 7 female) subjects who experienced both digital and conventional impression at the same day were enrolled in this study. Conventional impression were taken with polyvinylsiloxane and digital impression were performed using a newly developed intra-oral scanner. Immediately after the two impressions were made, a survey was conducted with the standardized questionnaires consisting of the following three categories; 1) general dental treatment 2) satisfaction of conventional impression 3) satisfaction of digital impression. The perceived source of satisfaction was evaluated using Likert scale. The distribution of the answers was assessed by percentages and statistical analyses were performed with the paired t-test, and P < 0.05 was considered significant. RESULTS: There were significant differences of the overall satisfaction between two impression methods (P < 0.05). Digital impression showed high satisfaction in less shortness of breath and odor to participants compared to conventional impression. The use of an oral scanner resulted in a discomfort of TMJ due to prolonged mouth opening and in lower score of the scanner tip size. CONCLUSION: It was confirmed that the preference for the digital impression using intraoral scanner is higher than the conventional impression. Most survey participants said they would recommend the digital impression to others and said they preferred it for future prosthetic treatment.
Dyspnea
;
Humans
;
Male
;
Mouth
;
Odors
;
Temporomandibular Joint
4.A review on the accuracy assessment methods of 3-dimensional digital dental models
Ji Su PARK ; Young Jun LIM ; Jungwon LEE ; Bongju KIM
Journal of Dental Rehabilitation and Applied Science 2019;35(2):55-63
The aim of this article was to review various methods used to evaluate the accuracy of digital dental models. When evaluating the accuracy of digital models, the errors can be reduced by educating examiners and using artificial landmarks. The accuracy evaluation methods of digital dental models are divided into linear measurement, 2-dimensional cross-sectional analysis, and 3-dimensional best fit measurement. As the technology of scanners develops, many studies have been conducted to compare the accuracy of digital impression and conventional impression. According to improvement of scan technologies and development of 3-dimensional model analysis software, the ability to evaluate the accuracy of digital models is becoming more efficient. In this article, we describe the methods for evaluating the accuracy of a digital model and investigate effective accuracy analysis methods for each situation.
Cross-Sectional Studies
;
Dental Models
;
Methods
5.Survey study on the Preference of Dental Medical Personnel for Dental CAD/CAM Milling Machines.
Eun Sung SONG ; Bongju KIM ; Young Joon LIM ; Jun Jae LEE
The Journal of Korean Academy of Prosthodontics 2018;56(3):188-198
PURPOSE: Recently, according to the development of digital technology, computer aided design/computer aided manufacture (CAD/CAM) system is widely used for fabrication of various dental prostheses in the field of dentistry. This study aims to survey the present state and awareness of CAD/CAM system on domestic dental field, and to supply the advice for the application of the new system. MATERIALS AND METHODS: In this questionnaire survey was conducted for a total of 298 dentists, dental hygienist and dental technicians of the whole country including the dental hospital of Seoul National University for two months from November to December, 2016 through mail. RESULTS: The most important purpose to consider when purchasing a dental CAD/CAM milling machine were the performance of the milling machine (64.43%) and the use of milling machine was the highest with 49.33% of manufacturing for dental prosthesis and customized implant abutment. In addition, more than 60% of respondents answered positively about the purchase of new milling machine if the CAD/CAM milling machine was improved to satisfactory performance. CONCLUSION: This survey results show that the improved CAD/CAM milling machine would be play an important role in the dental industry in preparation for digitization and the 4th industrial revolution.
Dental Hygienists
;
Dental Prosthesis
;
Dental Technicians
;
Dentistry
;
Dentists
;
Humans
;
Postal Service
;
Seoul
;
Surveys and Questionnaires
6.Bone-level implants placed in the anterior maxilla: an open-label, single-arm observational study.
EnFeng GAO ; Wei Hong HEI ; Jong Chul PARK ; KangMi PANG ; Sun Kyung KIM ; Bongju KIM ; Soung Min KIM ; Jong Ho LEE
Journal of Periodontal & Implant Science 2017;47(5):312-327
PURPOSE: This study assessed marginal bone remodeling and soft tissue esthetics after the loading of single bone-level implants in the anterior maxilla. METHODS: An open, single-arm observational clinical trial with 3 years of follow-up was performed, including 22 implants. The patients presented with a single tooth gap in the anterior maxilla (tooth positions 14–24), with natural or restored adjacent teeth. An implant was placed at least 8 weeks post-extraction and healed submerged for 6 weeks. After the second-stage operation, a fixed provisional prosthesis was provided. The final restoration was placed 6 months after the provisional restoration. The time of the provisional crown connection was considered to be the baseline in this study. Esthetic parameters and the marginal bone level were assessed at 6, 12, 24, and 36 months. RESULTS: All implants were well integrated in the bone. A statistically significant increase was found in the mean implant stability quotient between the time of the provisional prosthesis and the time of the final prosthesis. Most implants (95.5%) revealed marginal bone resorption (<0.5 mm), and just 1 implant (4.5%) showed a change of 2.12 mm from baseline to 36 months (mean 0.07±0.48 mm), while the crestal bone level decreased significantly, from 2.34±0.93 mm at baseline to 1.70±1.10 mm at 36 months. The facial gingival margin and papilla were stable and the esthetic scores indicated high patient and dentist satisfaction. CONCLUSIONS: Platform-switching bone-level implants placed in maxillary single-tooth gaps resulted in successful osseointegration with minimal marginal bone resorption. The peri-implant soft tissue was also esthetically satisfying and stable.
Alveolar Bone Loss
;
Bone Remodeling
;
Bone Resorption
;
Crowns
;
Dental Implants
;
Dentists
;
Esthetics
;
Follow-Up Studies
;
Humans
;
Maxilla*
;
Observational Study*
;
Osseointegration
;
Prostheses and Implants
;
Tooth
7.The Second-to-Fourth Digit Ratio in Cryptorchidism: A Case-Control Study.
Hawook HWANG ; Hyun Wook JO ; Bongju YUN ; Taewoo KIM ; Daeseon YU ; Jinsung PARK ; Dae Kyeng KIM ; Seung Hyo WOO
Korean Journal of Urology 2014;55(2):140-144
PURPOSE: The homeobox (Hox) genes a and d controlling limb and genital development influence the digit ratio and the fetal production of testicular androgen, which may result in testicular descent in boys. To assess whether the digit ratio reflects disease status, we investigated the second and fourth finger lengths in children with cryptorchidism, in children with hydrocele as a disease control, and in healthy controls (boys and girls). MATERIALS AND METHODS: One hundred ninety-six children (46 with cryptorchidism, 50 with hydrocele, 50 healthy boys, and 50 healthy girls) who were 6 to 23 months of age were prospectively enrolled. Digit lengths were measured by 2 investigators, and the mean value was recorded. RESULTS: The second-to-fourth digit ratios (2D:4Ds) of the left hand in the cryptorchidism group, hydrocele group, healthy boys, and healthy girls were 0.958, 0.956, 0.950, and 0.956, respectively. The 2D:4D values of the right hand were 0.946, 0.945, 0.952, and 0.969, respectively. The right and left 2D:4D ratios were not significantly different among groups. The 2D:4D of both hands was not related to age, weight, or height. CONCLUSIONS: According to these results, the 2D:4D was not significantly different in boys with cryptorchidism than in boys with hydrocele or in healthy controls (boys and girls) and failed to reflect disease conditions in the infant period.
Anthropometry
;
Case-Control Studies*
;
Child
;
Cryptorchidism*
;
Extremities
;
Female
;
Fingers
;
Genes, Homeobox
;
Hand
;
Humans
;
Infant
;
Male
;
Prospective Studies
;
Research Personnel
8.Influence of crown-to-implant ratio of short vs long implants on implant stability and marginal bone loss in the mandibular single molar implant
Yeon Wha BAEK ; Bongju KIM ; Myung Joo KIM ; Ho Beom KWON ; Young Jun LIM
Journal of Dental Rehabilitation and Applied Science 2018;34(4):280-289
PURPOSE: The purpose of this randomized clinical trial is to determine whether implant length and the crown-to-implant (C/I) ratio influence implant stability and peri-implant marginal bone loss (MBL). MATERIALS AND METHODS: 46 patients with single tooth missing in the posterior molar region of the mandible were included in this study. 19 implants (CMI IS-III active® long implant) of 5.0 mm diameter and 10 mm length were installed for the control group, while 27 implants (CMI IS-III active® short implant) of 5.5 mm diameter and 6.6, 7.3 or 8.5 mm length were placed for the experimental group. Each implant was inserted and immediately loaded using the digitally pre-fabricated surgical template and provisional restoration. The CAD-CAM monolithic zirconia crown was fabricated at 3 months after the surgery as a definitive restoration. The ISQ value and the MBL was measured at 48 weeks after the surgery. The correlation between the C/I ratio, MBL, and secondary implant stability was analyzed. RESULTS: Successful results in terms of ISQ and MBL were achieved with both groups. There was no significant difference between the groups in terms of ISQ values and MBL at 48 weeks after the surgery (P > 0.05). No significant correlation was found between the C/I ratio and secondary stability as well as the C/I ratio and the MBL (P > 0.05). CONCLUSION: The influence of C/I ratio in both groups was not shown on the stability nor the marginal bone loss in implants supporting single crown of the mandible. Short implant could be a preferable alternative option in the reduced bone height mandible under the limited condition despite its higher C/I ratio.
Computer-Aided Design
;
Crowns
;
Dental Implants
;
Humans
;
Mandible
;
Molar
;
Tooth
9.Use of Annular Closure Device (Barricaid(R)) for Preventing Lumbar Disc Reherniation: One-Year Results of Three Cases.
Bang Sang HAHN ; Gyu Yeul JI ; Bongju MOON ; Dong Ah SHIN ; Yoon HA ; Keung Nyun KIM ; Do Heum YOON
Korean Journal of Neurotrauma 2014;10(2):119-122
Although lumbar discectomy is an effective treatment for lumbar disc herniation, complications exist, including postoperative disc height loss, facet joint degeneration, and recurrent disc herniation. To solve these problems, annular closure devices have been utilized in other countries, producing satisfactory results, but there has been no report of annular closure device use in our country. Here, we demonstrate the preliminary reports of Barricaid(R) insertion in 3 patients who underwent surgery for lumbar disc herniation.
Diskectomy
;
Humans
;
Intervertebral Disc Degeneration
;
Lumbar Vertebrae
;
Zygapophyseal Joint
10.Per-oral cross-facial sural nerve graft for facial reanimation
Joohee JEONG ; Akram Abdo ALMANSOORI ; Hyun Soo PARK ; Soo Hwan BYUN ; Seung Ki MIN ; Han Wool CHOUNG ; Joo Yong PARK ; Sung Weon CHOI ; Bongju KIM ; Soung Min KIM ; Jong Ho LEE
Maxillofacial Plastic and Reconstructive Surgery 2018;40(1):22-
BACKGROUND: Cross-facial nerve graft is considered the treatment of choice for facial reanimation in patients with unilateral facial palsy caused by central facial nerve damage. In most cases, a traditional parotidectomy skin incision is used to locate the buccal and zygomatic branches of the facial nerve. METHODS: In this study, cross-facial nerve graft with the sural nerve was planned for three patients with facial palsy through an intraoral approach. RESULTS: An incision was made on the buccal cheek mucosa, and the dissection was performed to locate the buccal branch of the facial nerve. The parotid papillae and parotid duct were used as anatomic landmarks to locate the buccal branch. CONCLUSIONS: The intraoral approach is more advantageous than the conventional extraoral approach because of clear anatomic marker (parotid papilla), invisible postoperative scar, reduced tissue damage from dissection, and reduced operating time.
Anatomic Landmarks
;
Cheek
;
Cicatrix
;
Facial Nerve
;
Facial Paralysis
;
Humans
;
Mucous Membrane
;
Skin
;
Sural Nerve
;
Transplants