1.Infiltration of eosinophils and expression of intercellular adhesion molecule-1 in in vivo allergen-challenged nasal mucosa of allergic rhinitics.
Journal of Asthma, Allergy and Clinical Immunology 1998;18(2):280-289
We aimed to investigate the effect of in vitro allergen challenge on activation of eosinophils and expression of intercellular adhesion molecule-1(ICAM-1) in the epithelial and endothelial cells of the nasal mucosa of allergic rhinitics. MATERIALS AND METHODS: Inferior turbinate mucosal specimens which were obtained from 16 perennial allergic rhinitics and sensitized to D. farinae during conchotomy operations were used. Each mucosal specimen was divided into six pieces. The first two pieces were used as basic control group without culture, the second two pieces as culture-control group which was cultured with diluent only, and the last two pieces as antigen-challenge group cultured with D. farinae solution for 24 hours. Specimens were immunohistochemically stained using monoclonal antibody against eosinophil cationic protein(EG1 for all eosinophils and EG2 for activated forms) and ICAM-1. RESULTS: Average counts of EG1 cells and EG2+ cells within 1 mm of lamina propria of nasal mucosa were 14 and 11 respectively in the basic control group, 17 and 19 in culture control group, and 16 and 16 in the antigen-challenge group. ICAM-1 expression on vessels was observed more than half of t,he vessels in the nasal mucosa and there was no significant difference between groups, however, its expression on the epithelial cells was most prominent in the antigen-challenge group (2.1 in basic control group, 3.3 in culture control group, and 6.2 in antigen-challenge group). CONCLUSION: Most of the eosinophils infiltrating into the nasal mucosae out of vessels in allergic rhinitics are activated forms. Significant up-regulation of epithelial ICAM-1 expression by antigen-challenge suggests that ICAM-1 contributes to the transmigration of eosinophils from the subepithelial tissue into the epithelial cell layer and then finally into the nasal secretion.
Endothelial Cells
;
Eosinophils*
;
Epithelial Cells
;
Intercellular Adhesion Molecule-1*
;
Mucous Membrane
;
Nasal Mucosa*
;
Turbinates
;
Up-Regulation
2.Endothelial and epithelial expression of adhesion molecules and infiltration of eosinophils in the nasal polyps.
Korean Journal of Allergy 1997;17(1):67-77
BACKGROUND: Eosinophils are suggested to play a deleterious role in the inflammatory disease of the respiratory mucosa by releasing granule substances such as major basic prorein and eosinophil cationic protein. To investigate the contribution of eosinophils in the pathogenesis of nasal polyps and the mechanism of their accumulation and activation, we observed the eosinophil inhllration and expression of endotjelial and epithelial cell adhesion molecules in the nasal polyp tissues. MATERIALS AND METHODS: Polyp and inferior turbinate mueosal specimens (polyp group) taken out of 20 patients and 10 inferior turbinate mucosa specimens of non-allergic and non-infectious controls (control group) were immunohistochemically stained using EG1, EG2, and mAb for the ICAM-1, VCAM-1 and E-seleetin. The number of EG1 (+) and EG2 (+) cells within lmm2 of tissue and the expression of ICAM-1, VCAM-1 and E-seleetin on the vessels (% of total vessel) and epithelial eelis (area x intensity) were compared among three groups. RESULTS:The inferior turbinate mucosae of nasal polyp patients .were infiltrated by signifieantly higher number of eosinophils (EG1:17, EG2:16/mm2) compared with those of controls (EGi:0, EG2:0/mm2) (p<0.05), and the polyp tissue revealed much more eosinophils (EG1: 213, EG2:154/mm2) than inferior turbinates of same patients and those of controls (p<0.001). ICAM-1 expression in the vessels was frequenly observed both in polyps and in the turbinate mucosae with significant difference (median:85% vs. 67%, p<0.05), and ICAM-1 expression in the epithelial ceils was significantly different between the polyp and turbinate groups (median:9 vs. 2.5, p<0. 01). VCAM-1 was moderately expressed on the vessels of both polyps and turbinate mucosac (median:37%, 14%, respectively) and their expressions were significantly different (p<0.01). E-selectin expression was moderate to low both in the polyps and in the turbinate mucosae (median:18%, 10% respectively) and their expressions were not significantly different (p>0.05). CONCLUSION: Most of the eosinophils infiltrated into nasal tissue as well as nasal polyps were activated forms and they were significantly increased in the nasal polyps compared to the inferior turbinate mueosae of the same patients and control subjects. Significantly increased expression of ICAM-1 and VCAM-1 on the vessels and increased epithelial ICAM-1 expression in the nasal polyps indicate that interactions of eosinophils with ICAM-1 and VCAM-1 participate in the pathogenesis of nasal polyps.
E-Selectin
;
Eosinophil Cationic Protein
;
Eosinophils*
;
Epithelial Cells
;
Humans
;
Intercellular Adhesion Molecule-1
;
Mucous Membrane
;
Nasal Polyps*
;
Polyps
;
Respiratory Mucosa
;
Turbinates
;
Vascular Cell Adhesion Molecule-1
3.Influence of synthetic polyadenylic. polyuridylic acid on the productions of interferon-?and interleukin-4 in mice.
Jung Koo YOON ; Bong Ki LEE ; Jun Soo SHIN
Journal of the Korean Cancer Association 1993;25(4):586-594
No abstract available.
Animals
;
Interleukin-4*
;
Mice*
4.Statistical Study on Optimal Placement of Immediate Dental Implantation Using Denta Scanr.
Kwang Ho SHIN ; Jai Bong LEE ; Byung Nam HWANG
The Journal of Korean Academy of Prosthodontics 2000;38(4):552-560
PURPOSE : The purpose of this study was to determine proper position and angulation of an implant for immediate implantation. MATERIALS AND METHOD : From the years 1997 to 2000, 52 Denta scanR views, 22 upper and 32 lower jaw with an average age of 43 and 40 respectively, were investigated, which comprise intact upper and lower 6 anterior teeth and premolars. on the Denta scanR, the optimal placement for the immediated implantation was simulated. The measuring methods included. 1) Angulation difference between tooth long axis and alveolar bone process. 2) Angulation difference of long axis between tooth and installing fixture 3) Distance between center of tooth at cervical area and center of fixture. 4) Distance from root apex to the bone limit of vital structure. One sample t-test was used for statistical analysis. RESULT : The results were as follows. 1) At the maxillary central incisor and lateral incisor, angulation difference of long axis between tooth and installing fixture was respectively 0.5 and 3.2degrees with the fixture center's palatally positioned 2mm apart from tooth center. 2) At the lower anterior 6 teeth, that was about -2.8degree to -4.6degree with the fixture center's lingually positioned 1mm apart from tooth center. 3) At the maxillary canine and premolar, that was respectively 11.8degree and 7.2degree with the fixture center palatally positioned 2~2.4mm apart from tooth center. 4) At the lower premolar area, that was about 0degree to 2degree with the fixture center's lingually positioned 0.5~1mm apart from tooth center. 5) Distance from root apex to the bone limit of vital structure, at the maxillary anterior and premolars, was the range of 10 to 12mm, and at the mandibular anterior teeth and the 1st premolar, that was the range of 18 to 20mm. CONCLUSION : The proper implant position of maxillary anterior and premolar teeth is as paralleled as or more buccally angulated than long axis of tooth with the fixture center's palatally positioned. in mandibular anterior region, long axis of implants is lingully angulated compared with compared with long axis of tooth and in premolar, almost parelleled with long axis of tooth and alveolar process.
Alveolar Process
;
Axis, Cervical Vertebra
;
Bicuspid
;
Dental Implantation*
;
Dental Implants*
;
Incisor
;
Jaw
;
Statistics as Topic*
;
Tooth
5.A Clinical Study of the Operative Treatment for the Spondylolisthesis
Sang Eun LEE ; Bong Keun KIM ; Moon Ho SHIN
The Journal of the Korean Orthopaedic Association 1987;22(5):1112-1121
We reviewed 35 patients who received an operation for the Spondylolisthesis from July 1980 to July 1985. The follow-up period between operation and evaluation was at least 14 months and average 32 months. we obtained the following results. 1. The age distribution was from 23 years of age to 70 years of age and the prevalent decade was at the 5th. 2. Sex difference showed male 9 cases and female 26 cases, that is, female preponderance about 3 times. 3. 24 cases were isthmic type and 11 cases were degenerative type. The ratio between isthmic type and degenerative type was about 2: l. 4. Isthmic type was found at the 4th and 5th decades frequently and degenerative type was at 5th and 6th decade frequently. 5. The displacement between L4 and L5 was 21 cases and the displacement between L5 and sacrum was 14 cases. 6. In isthmic type, the displacement between L4 and L5 was 11 cases and the displacement between L5 and sacrum was 13 cases. In degenerative type, the displacement between L4 and L5 was 10 cases and the displacement between L5 and sacrum was 1 case. So the isthmic defect occurred at 2 levels almost equally and degonerative type occurred at L4-5 predominantly. 7. Overall results are excellent 2 cases(6%), good 29 cases(82%), fair 2 cases(6%), and poor 2 cases (6%).
Age Distribution
;
Clinical Study
;
Female
;
Follow-Up Studies
;
Humans
;
Male
;
Sacrum
;
Sex Characteristics
;
Spondylolisthesis
6.FRACTURE TOUGHNESS OF VARIOUS CORE MATERIALS.
Shin Won LEE ; Sun Hyung LEE ; Jae Ho YANG ; Jung Suk HAN ; Jai Bong LEE
The Journal of Korean Academy of Prosthodontics 2001;39(6):682-697
This investigation evaluated the fracture toughness (KIC) of eight currently available core materials, and relate the fracture toughness value to fractography analysis and surface characteristics using a atomic force microscope (AFM). Single-edge notched (SEN) test specimens (n=10) and compact tension (CT) test specimens (n=10) were prepared conforming to the ASTM Standard E-399 for a high copper amalgam, three composite core materials (Core-Max II, Core Paste, Bisfil Core), two reinforced composite core materials (Ti-Core, Ti-Core Natural), a resin-modified glass ionomer core material (Vitremer), and a conventional glass ionomer core material (Ketac-Molar). The specimens were tested with an Instron Universal Testing Machine. The maximum loads were measured to calculate the fracture toughness (KIC). Thereafter, fracture surfaces of SEN specimens of each material were investigated for fractography analysis using scanning electron microscope. And, disc-shaped specimens with 1mm thickness were fabricated for each material and were investigated under AFM for surface morphology analysis. The results were as follows : 1. Bisfil Core showed the highest mean fracture toughness regardless of test methods. 2. For the tooth-colored materials, Ti-Core Natural exhibited the highest fracture toughness. 3. Ketac Molar showed a significantly low fracture toughness when compared with the amalgam and the composite resin core materials (p<0.05). 4. The fracture toughness values obtained with the single-edge notched test, except Ketac Molar, were higher than those obtained in the compact tension test. 5. SEM revealed that the fracture surface of high fracture toughness material was rougher than that of low fracture toughness material. 6. AFM revealed that the surface particles of the composite resins were smaller in size, with a lower surface roughness than the glass ionomer core materials.
Composite Resins
;
Copper
;
Glass
;
Molar
7.Sacral Fracture Dislocation of Suicidal Jumper (Suicidal Jumper's Fracture): 4 Cases Report.
Sang Wook LEE ; Sang Bong KO ; Dong Young SHIN
Journal of Korean Society of Spine Surgery 2008;15(4):281-285
Displaced fractures of the upper sacrum are a rare type of high energy injury, such as a fall, with similar neurological symptoms and fracture patterns. The authors treated 4 patients with these fracture patterns surgically or conservatively and followed them up for at least 1 year. We report these 4 cases with a review of the relevant literature.
Dislocations
;
Humans
;
Sacrum
8.An Experimental Study on the Survival of Membranous Inlay Bone Graft on the Mandible.
Bong Soo BAIK ; Dong Pill SHIN ; Dong Hun LEE ; Jung Hyung LEE ; Byung Chae CHO
Journal of the Korean Society of Plastic and Reconstructive Surgeons 1999;26(4):677-682
Bone graft is an important procedure in craniomaxillofacial reconstruction and the success of reconstruction depends on the survival of the grafted bone. In this study, the survival of the membranous inlay bone graft on the mandibles of dogs was investigated with bone scan and histologic examination. The inlay bone graft, 1x2cm critical-sized bone, was completely separated from the lower border of the mandible of dogs and then refixed to the original site. Bone scan and histologic examination were done at 1,2,3 and 4 weeks postoperatively. The bone scan after 1 week showed radioisotope uptake on the margin of the grafted bone and the isotope count was 21% compared to the uptake of the normal bone. After 2 weeks, the radioisotope uptake in the grafted bone increased to 52% of normal bone uptake. After 3 and 4 weeks, the degree of isotope uptake was 111% and 124% respectively. Histological findings after 1 week showed the absence of osteoblastic activity and 6 viable blood vessels in one 200X magnified field, which was 25% compared to the vessels of the normal bone. After 2 weeks, osteoblastic activities were noted and the number of viable blood vessels totalled 15, which was 63% of the vessels of the normal bone. After 3 weeks, osteoblastic activities increased and the number of viable blood vessels totalled 21, which was 88% of the vessels of the normal bone. After 4 weeks, there were markedly increased osteoblastic activities with a total number of 23 vessels, which was 96% of the normal bone. In summary, the revascularization of the membranous inlay bone graft began from the first week after bone graft, and then it gradually increased. After 3 weeks, the revascularization had returned to a nearly normal value compared with the value of the near-by normal mandibular bone.
Animals
;
Blood Vessels
;
Dogs
;
Inlays*
;
Mandible*
;
Osteoblasts
;
Reference Values
;
Transplants*
9.A case of erythropoietic protoporphyria.
Ha Wook BONG ; Joo Heung LEE ; Yoo Shin LEE ; Jung Ho KIM
Korean Journal of Dermatology 1993;31(5):817-822
Erythropoietic protoporphyria, sometimes also called erythrohepitic protoporphyria or simple protoporphyria, is a heritable detect of heme synthesis in which the last enzyme of the heme synthetic pathway, ferrochelatase(or heme synthetase), is functioning subopt,imally. A 23-year-old male has experi nced erythema and edema on the fae and hands during or immediately after sun exposure, since 3 years of age. The skin lesions have been accompanied by severe itching, a buring sensation and pain. Severe episodes were followed hy head iche and vomiting. We have seen a case of erythropoietic protoporphyria presenting clinically and histo athologically, wit.h a skin lesion on the sun exposured area, and free erthrocyte protoporphyrin serologically.
Edema
;
Erythema
;
Hand
;
Head
;
Heme
;
Humans
;
Male
;
Protoporphyria, Erythropoietic*
;
Pruritus
;
Sensation
;
Skin
;
Solar System
;
Vomiting
;
Young Adult
10.CS-3000 Plus Cell Separator; A-35 Collection Chamber vs PLT-30TM Collection Chamber.
Oh Hun KWON ; Hyun Ok KIM ; Seun Moo LEE ; Hee Bong SHIN ; Chun Hyun NAHM
Korean Journal of Blood Transfusion 1996;7(1):49-55
BACKGROUND: Recently, it has been established that plateletpheresis needs more efficiency and shorter processing time. Fenwall laboratories developed a new collection chamber for CS-3000 Plus, PLT-30TM collection chamber, which can reduce the processing time with efficient collection. We evaluated the PLT-30TM collection chamber by comparing it with A-35 collection chamber that has been used as a standard collection chamber of CS-3000 Plus us. METHODS: Thirty platelet collection procedures were performed using the CS 3000 Plus with A-35 collection chamber and PLT-30TM collection chamber. The changes of the hematologic parameters between pre- and post-donation in donors and the total platelets yields and the contaminated WBCs in the plateletpheresis products were evaluated. In processing, the yield predictor calibration was adjusted to 1.00 and 1.13 in A-35 and PLT-30TM respectively. Yield predictors of pheresis were the same as 3.5x1011 in both and end point volumes were calculated from the CS-3000 Plus. Processing volume and processing times were compared between A-35 and PLT-30TM groups. RESULTS: With PLT-30TM collection chamber, 3.38+/-0.72x1011/L platelets were harvested, whereas 3.20+/- 0.73x1011/L were collected with A-35 collection chamber, which was not significantly different. But processing time with the PLT-30TM collection chamber was more reduced than that with the A-35 collection chamber by about 20 minutes (PLT-30TM : 88.6+/-8.4 min, A-35 : 106.7+/-11.7min). Collection efficiency of PLT-30TM chamber was 50.7+/-12.5% and that of A-35 chamber was 44.4 + 8.8%. The leukocyte contamination of the platelet concentrates were not statistically different(PLT-30TM: 0.0-3.6x106, A-35 : 0.1-4.1x106). CONCLUSIONS: PLT-30TM collection chamber has the advantages of shortening the donation time and decreasing the processing volume with better collection efficiency and flexibility of platelet concentrate volume.
Blood Component Removal
;
Blood Platelets
;
Calibration
;
Humans
;
Leukocytes
;
Plateletpheresis
;
Pliability
;
Tissue Donors