1.Prenatally diagnosed split hand malformation at 16 weeks' gestation by 3D ultrasonography.
Korean Journal of Obstetrics and Gynecology 2008;51(12):1509-1513
Split hand malformation is a rare malformation with various presentations. The current report describes a case of split hand malformation detected using 2D and 3D ultrasonography at 16 weeks` gestation. 2D ultrasonographic findings were split hand malformation in the right hand and monodactyly in the left hand , and those findings were confirmed and further clarified using 3D imaging. Postmortem X ray findings were consistent with the ultrasonographic findings. We conclude that 3D ultrasonography can assist in clarifying 2D ultrasonography findings of hand malformations during the second trimester of pregnancy.
Female
;
Hand
;
Humans
;
Pregnancy
;
Pregnancy Trimester, Second
;
Prenatal Diagnosis
2.Comparision between Manifest vs. Cycloplegic Photore fraction with MTI Photoscreener in Prematurity.
June Seok RHEE ; Sang Ki AHN ; Bon Sool KOO
Journal of the Korean Ophthalmological Society 2000;41(2):475-482
Amblyopia and strabismus are common in eyes of prematurity and the need for early detection of amblyopia and amblyogenic factors is widely recognized. So, we performed refraction in premature infants at the 6 months of age to evaluate the incidence and degree of myopia and the changes of refractive errors according to the development, disease course and photocoagulation therapy of retinopathy of prematurity[ROP]. It is the purpose of this study to evaluate the effectiveness of MTI[medical Technology, Inc]photoscreener by comparing the sensitivity and specificity between refractive errors determined by manifest photorefraction and cycloplegic photorefraction in 6-month-old premature infants in Sung-Ae General Hospital. Pass or fail screening data from photograph of 32 non-dilated and dilated premature infant were calculated by two masked observers, compared with the results of cycloplegic retinoscopy, and the statical analysis was carried out. In the cases of cycloplegic photorefraction, Ten eyes of myopia, 4 eyes of emetropia, and 50 eyes of hyperopia were found, and 21 eyes of astigmatism above 1.5D were also detected. Overall statistical analysis of sensitivity and specificity rate were 71.7% and 69.5%in manifest photorefraction, 87.5% and of 75%in cycloplegic photorefraction, respectively. In non-cycloplegic photorefraction, sensitivity of myopia and hyperopia were 92.8%, 65%, but in cycloplegic photorefraction, sensitivity of myopia and hyperopia were 75%, 100%, respectively. The outcomes of our study suggest that MTI photoscreener in cycloplegic photorefraction was more reliable than non-cycloplegic photorefraction. Myopia under 1D turned to hyperopia in cycloplegic photorefraction, so the sensitivity of that was not to be reliable, but the sensitivity of hyperopia was high. Thus, the authors can readily recommand this cycloplegic photorefraction in uncooperable infants to evalute the refractive error conveniently.
Amblyopia
;
Astigmatism
;
Hospitals, General
;
Humans
;
Hyperopia
;
Incidence
;
Infant
;
Infant, Newborn
;
Infant, Premature
;
Light Coagulation
;
Masks
;
Mass Screening
;
Myopia
;
Refractive Errors
;
Retinoscopy
;
Sensitivity and Specificity
;
Strabismus
3.Preschool Vision Screening for 3 to 6-Year Old Children in Korea.
Journal of the Korean Ophthalmological Society 2003;44(4):971-981
PURPOSE: To inform the necessity of mass screening, we performed a mass screening for the detection of ocular disorders of preschool children. METHODS: Ocular examination was performed on 60, 827 children in Korea (3-6 years of age) during the period from March to October, 2000. The total of 3, 254 children were shown to have either visual acuity of less than 0.5 or anisometropia of over 2 lines. Detailed eye examination was conducted on those 3, 254 children. RESULTS: The numbers of first mass screening were 60, 826. Diagnosis consisted of refractive errors in 2, 216, amblyopia in 664, and strabismus in 235. Among the types of refractive errors, myopic astigmatism was the most common type (34.0%). Astigmatism was combined with all other types in 1, 659 children. Refractive error was the most common cause of amblyopia (88.0%) CONCLUSIONS: To prevent and treat amblyopia or strabismus, early detection and adequate care at preschool age seemed to be very effective. Participation rate for this mass-screening of eye disease during preschool age will be more increased by efforts of constiutional support and parental cooperation.
Amblyopia
;
Anisometropia
;
Astigmatism
;
Child*
;
Child, Preschool
;
Diagnosis
;
Eye Diseases
;
Humans
;
Korea*
;
Mass Screening
;
Parents
;
Refractive Errors
;
Strabismus
;
Vision Screening*
;
Visual Acuity
4.Clinical efficiency of the measurement of fetal nuchal translucency and Doppler examination of ductus venosus as a screening tool for chromosomal abnormalities.
Korean Journal of Obstetrics and Gynecology 2009;52(1):61-67
OBJECTIVE: To evaluate the efficiency of the measurement of fetal nuchal translucency (FNT) and ductus venosus Doppler examination (DV Doppler) as a screening tool for chromosomal abnormalities. METHODS: FNT measurement and DV Doppler wereperformed in 950 pregnancies between 11(+0)~13(+6) weeks' gestation. Chromosomal analysis was done when FNT was more than 3 mm and DV Doppler showed absent flow or reversed flow. The numbers of cases with increased FNT and abnormal DV Doppler were counted in the groups of abnormal and normal karyotype. RESULTS: Data were available in 912 pregnancies. 11 pregnancies showed abnormal karyotype (1.2%). In the 11 cases with abnormal karyotype,increased FNT was found in 8 cases with 72.7% sensitivity and abnormal DV Doppler was found in 5 cases with 45.4% sensitivity. In the 901 cases withnormal karyotype, increased FNT was found in 33 cases with 96.3% specificity and abnormal DV Doppler was found in 12 cases with 98.7% specificity. Positive predictive value was 19.5% in cases of increased FNT, 29.4% in cases of abnormal DV Doppler, and 44.4% in cases of increased FNT and abnormal DV Doppler both. CONCLUSION: There is no improvement in general screening for chromosomal abnormalities when FNT measurement and DV Doppler were performed together. But better specificity and positive predictive value for chromosomal abnormalities were found.
Abnormal Karyotype
;
Chromosome Aberrations
;
Karyotype
;
Mass Screening
;
Nuchal Translucency Measurement
;
Pregnancy
;
Sensitivity and Specificity
5.A Case of Cryptophthalmos Syndrome.
Ho Seek AHN ; Gyu Ha LEE ; Eui Bon KOO ; Sung Won KIM ; Kil Hyen KIM
Journal of the Korean Pediatric Society 1990;33(2):274-277
No abstract available.
6.A Case of Ossification in the Phthisis Bulbi.
Duk Hun HYUN ; Nam Ju MOON ; Bon Sool KOO
Journal of the Korean Ophthalmological Society 1997;38(5):897-901
Phthisis bulbi, resulting from repeated ocular inflammation and infection or ocular trauma, causes various degeneration of ocular tissue as well as changes in ocular external shape. It shows the impression of scleral thickening with calcification of ocular tissue and an unusual ossification as well. Having observed 31-year-old patients of phthisis bulbi and band keratopathy caused by repeated operation after ocular trauma years ago, we extracted the tan brown colored shell-like firm tissue in posterior segment and report sclerotic impression of some of ocular tissue and histopathologic finding of the typical ossificationof ocular tissue during the course evisceration.
Adult
;
Humans
;
Inflammation
;
Triacetoneamine-N-Oxyl
7.Clinical Evaluation of Ophthalmic Injury Associated with Head Injury.
Duk Hun HYUN ; Nam Ju MOON ; Bon Sool KOO
Journal of the Korean Ophthalmological Society 1996;37(10):1753-1760
Secondary eyeball injury can be caused by head injury as well as direct injury of the eyeball or the orbit. Authors of this report have researched on 117 patients who were applied for ophthalmic examination which in care of the neurosurgical department and have researched frequency of secondary eyeball injury, association between the eyeball injury and the head injury, and favourable frequency of the eyeball injury which were developed without direct injury of the eyeball. There were 21 eyes(9.0%) with external ocular abnormality in 18 patients which included lagophthalmos, ptosis, paralytic strabismus, and there were 14 eyes(6.0 %) with posterior segment abnormality which were vitreoretinal hemorrhage, option. injury and papilledema in 11 patients. In association between the head injury and the eyeball injury, there were many external paralytic injury in basal skull injury and many posterior segment injury in cerebral parenchymal injury. After their injury, follow-up was executed in 3 month interval for 12 month. 15 eyes with external ocular abnormality and 8 eyes with posterior segment abnormality showed favourable progression. Posterior segment abnormality improved statistically significant at 3 month after injury(p<0.05). Secondary ophthalmic injury can be caused by various head injuries. Based on periodic observation, external ocular abnormality improved frequently at more than 9 months after injury. In cases of posterior segment abnormality, there was statistically significant improvement at 3 month after injury(p<0.05). Thus careful observation and treatment should be made in its early stage.
Craniocerebral Trauma*
;
Follow-Up Studies
;
Head*
;
Hemorrhage
;
Humans
;
Orbit
;
Papilledema
;
Skull
;
Strabismus
8.Congenital Cytomegalovirus infection.
Kang Woo PARK ; Ho Seek AHN ; Eui Bon KOO ; Sung Won KIM ; Kil Hyun KIM
Journal of the Korean Pediatric Society 1990;33(9):1271-1275
No abstract available.
Cytomegalovirus Infections*
;
Cytomegalovirus*
9.A case of Meconium Peritonitis.
Youn Young YU ; Hyun Soon LEE ; Eui Bon KOO ; Sung Won KIM ; Gil Hyun KIM
Journal of the Korean Pediatric Society 1990;33(9):1266-1270
No abstract available.
Meconium*
;
Peritonitis*
10.Effect of the Illumination and the Types of the Lenses on Near Visual Acuity in Low Vison Patients.
Dong Su SHIN ; Sung Won JUNG ; Sang Ki AHN ; Bon Sool KOO
Journal of the Korean Ophthalmological Society 1997;38(9):1677-1681
To obtain adequate information of illumination and lens types for visual acuity test of low vision patient, the relation between various illumination and vision was evaluated. Visual acuity for near and effective lens types were examined. Among the 28 patients (of 36 eyes), intensities of illumination were set at 200, 500, 1000 and 2000lux and the lenses of biconvex, aspheric and aplanatic were tested. The best visible range of illumination for the low vision patients was 500-1000lux, with lower power diopter for the same visual acuity and with aspherin and aplantic lenses. Results attained by our study may be applied for appropriate condition of illumiation and type of lens in the low vision care.
Humans
;
Lighting*
;
Vision, Low
;
Visual Acuity*