1.Laboratory study on reproducibility of no-albumin human plasma by rivanol precipitation Ⅰ.Purification or isolation of protein C and protein S
Yonghui TAO ; Jian JIN ; Bocheng WANG ; Manda ZHANG ; Changgeng RUAN
Chinese Journal of Biochemical Pharmaceutics 2001;22(3):121-124
Purpose The aim is to isolate and purify Protein C(PC) and Protein S(PS) from no-albumin human plasma by rivanol precipitation. Methods The isolated and purified steps included adsorption onto and elution from barium, salting-out, ion-exchange chromatography, affinity chromatography,preparative isoelectric focusing and so on. Results The molecular weights of the obtained PC and PS were (61±0.9)kD and (83±0.8)kD, respectively, the isoelectric point, 4.70±0.03 and 5.20±0.03,and the yield, 28.3% and 12.6%. The purified PC and PS were shown to be highly homogeneous by capillary zone-electrophoresis(CZE), and rich in Glu, Leu and Gly or Asp, Glu and Leu respectively. Conclusion The methods could be used for large-scale isolation and purification of PC and PS from no-albumin human plasma.
2.Simultaneous Determination of the Content of Berberine Hydrochloride,Baicalin and Osthole in Jinchan Zhiyang Capsules by HPLC
Chuanjun HUANG ; Yong MEI ; Li YANG ; Lei LUO ; Bocheng ZENG ; Tao LONG ; Kaichao YUAN ; Zhiwen QIAO ; Xiaoxue CHEN
China Pharmacy 2018;29(12):1621-1624
OBJECTIVE:To establish the method for simultaneous determination of the content of berberine hydrochloride, baicalin and osthole in Jinchan zhiyang capsules. METHODS:HPLC method was adopted. The determination was performed in Hypersil BDS C18 column with mobile phase consisted of methanol-acetonitrile-0.1%phosphoric acid-three triethylamine(50∶30∶19∶1, V/V/V/V) at the flow rate of 1.0 mL/min. The detection wavelengths were set at 265 nm (berberine hydrochloride),280 nm (baicalin)and 322 nm(osthole). The column temperature was set at 30 ℃,and sample size was 10 μL. RESULTS:The linear range of berberine hydrochloride,baicalin and osthole were 80-800 ng(r=0.999 8),60-600 ng(r=0.999 9),60-600 ng(r=0.999 6),respectively. RSDs of precision,stability and reproducibility tests were all lower than 2.0%. The limits of quantitation were 80,60,60 ng,respectively,and the limits of detection were 24,20,20 ng,respectively. The recovery rates were 97.4%-98.3%(RSD=0.33%,n=6),98.4%-99.6%(RSD=0.42%,n=6)and 96.9%-99.0%(RSD=0.92%,n=6),respectively. RSDs of durability tests were all lower than 1.2%. CONCLUSIONS:The method is simple, accurate, precise, stable, reproducible and durable. It can be used for simultaneous determination of berberine hydrochloride,baicalin and osthole in Jinchan zhiyang capsules.
3.Effects of polystyrene microplastics on growth and development and hepatic lipid metabolism in mice
Xinxue GAO ; Jiaxin GAO ; Jianyu ZHU ; Xinqi SHI ; Bocheng TAO ; Ning LI ; Lijuan CHEN
Chinese Journal of Tissue Engineering Research 2024;28(29):4634-4638
BACKGROUND:Plastic as a durable,inexpensive,easy to manufacture organic synthetic polymer materials are widely used.At the same time,plastic resistance to high temperatures,acid and alkali resistance,corrosion-resistant properties make it difficult to degrade in nature,and ultimately forming a huge number of microplastic pollution threatening human health. OBJECTIVE:To investigate the effects of microplastic exposure on growth and development and hepatic lipid metabolism in mice. METHODS:Twenty C57BL/6J male mice were adaptively fed for one week,and then randomly divided into normal and microplastic groups(n=10 per group).Mice in the normal group were given a normal diet and water,for 4 weeks.Mice in the microplastic group were given a normal diet and free drinking of microplastic(polystyrene)water with a concentration of 1 000 μg/L,for 4 weeks.At 2 and 4 weeks of drinking,body mass and grip strength,blood lipids and liver and kidney function,ultrasonic morphology and pathological morphology of liver and lipid deposition were detected. RESULTS AND CONCLUSION:(1)With the extension of time,the body mass of mice in the two groups gradually increased,and the body mass of mice in the microplastic group was greater than that in the normal group after 2,4 weeks of drinking water(P<0.05).With the extension of time,the grip strength of mice in the normal group gradually increased,and the grip strength of mice in the microplastic group first decreased and then increased,and the grip strength of mice in the microplastic group was lower than that in the normal group after drinking water for 4 weeks(P<0.05).(2)Liver ultrasound examination showed that compared with the normal group,the ultrasonic echo signal of the liver in the microplastic group was enhanced after 2 and 4 weeks of drinking water.(3)Hematoxylin-eosin staining showed that the morphology of liver cells in the microplastic group did not change significantly after 2 and 4 weeks of drinking water,but inflammatory cell infiltration could be seen.Oil red O staining showed that obvious lipid deposition was observed in the liver of microplastic group after 2 and 4 weeks of drinking water.(4)Compared with the normal group,the levels of serum high density lipoprotein cholesterol,triacylglycerol,and aspartate aminotransferase in the microplastic group were decreased after 2 weeks of drinking water(P<0.05),and the serum triacylglycerol concentration was decreased after 4 weeks of drinking water(P<0.05).(5)These findings confirm that microplastics may cause weight gain,loss of physical strength,and abnormal hepatic lipid metabolism in mice.
4.Simultaneous Determination of Berberine Hydrochloride and Baicalin in Jianpi Zhixiening Granules by HPLC-switching Walvelength Method
Chuanjun HUANG ; Li YANG ; Yong MEI ; Lei LUO ; Shanshan LYU ; Bocheng ZENG ; Tao LONG ; Feng WANG ; Juan ZUO ; Kaichao YUAN ; Pan TANG ; Feng ZHU ; Bo CHEN ; Zhiwen QIAO
China Pharmacy 2018;29(10):1324-1327
OBJECTIVE:To establish the method for simultaneous determination of berberine hydrochloride and baicalin in Jianpi zhixiening granules. METHODS:HPLC switching walvelength method was adopted. The determination was performed on Hypersil BDS C18 column with mobile phase consisted of methanol-0.45% phosphoric acid solution-triethylamine(50:49:1,V/V/V) at the flow rate of 1.0 mL/min. The detection wavelength was set at 265 nm(berberine hydrochloride)and 280 nm(baicalin). The column temperature was set at 30 ℃,and sample size was 10 μL. RESULTS:The linear range of berberine hydrochloride and baicalin were 60.3-312.8 ng(r=0.9997)and 81.5-368.9 ng(r=0.9999). The limits of quantitation were 0.6668,0.7740 ng,andthe limits of detection were 0.2226,0.2580 ng,respectively. RSDs of intermediate precision,stability and repeatability tests were all lower than 1.0%. The recoveries were 96.48%-99.30%(RSD=1.06%,n=6) and 95.20%-99.39%(RSD=1.66%,n=6), respectively. RSDs of durability test were all lower than 2.0%. CONCLUSIONS:The method is simple, precise, stable, reproducible,accurate and durable. It can be used for simultaneous determination of berberine hydrochloride and baicalin in Jianpi zhixiening granules.
5.Improved ability of demonstrating ocular masses on 3.0 T MR scanner combined with an 8-channel eye surface phased array coil: a multi-center study
Shijun WANG ; Hong JIANG ; Feifei WANG ; Meiyun WANG ; Guanghui BAI ; Qinghe HAN ; Bocheng WANG ; Jingliang CHENG ; Chuanliang CHEN ; Huaizhi GE ; Qinghai YUAN ; Xiaofeng TAO ; Junfang XIAN
Chinese Journal of Radiology 2023;57(1):41-47
Objective:To investigate the value of the 8-channel eye surface phased array coil in improving image quality and demonstrating ocular masses on 3.0 T MR scanner.Methods:From July 2018 to January 2020, the data of orbital MRI in 692 patients with ocular masses on 6 medical centers were prospectively collected. The patients were simple randomly assigned into 8-channel eye surface phased array coil group (413 patients) or 8-channel head phased array coil group (279 patients), with the same MRI sequences. The signal to noise ratio (SNR) and contrast to noise ratio (CNR) were calculated in orbital anatomy structures and masses (eyelid mass, intraocular mass, lacrimal mass and orbital mass). The image quality scores including motion artifact, mass margin, the relationship between the mass and adjacent structures, and overall image quality were recorded. The differences of image quality between the two groups were compared by two independent sample t-test or Wilcoxon rank test. Results:The SNR and CNR were higher in eye surface coil group than those in head coil group ( P<0.05). The scores of ocular movement artifacts were higher in head coil group than those in surface coil group ( P<0.05). The scores of intraocular mass margin, the relationship between the mass and adjacent structures, and overall image quality were higher in surface coil group than those in head coil group ( P<0.001). There were no significant differences in mass margin, the relationship between the mass and adjacent structures, and overall image quality scores of eyelid, lacrimal gland, and orbital mass between the two groups ( P>0.05). Conclusion:3.0 T MR scanner combined with the 8-channel eye surface phased array coil can improve the SNR and CNR of orbital MR images, the demonstration of the intraocular mass margin and the relationship between the mass and adjacent structures.
6.Improved ability of demonstrating ocular masses on 3.0 T MR scanner using PROPELLER: a multi-center study
Hong JIANG ; Guanghui BAI ; Qinghe HAN ; Meiyun WANG ; Feifei WANG ; Bocheng WANG ; Shijun WANG ; Huaizhi GE ; Qinghai YUAN ; Chuanliang CHEN ; Jingliang CHENG ; Xiaofeng TAO ; Junfang XIAN
Chinese Journal of Radiology 2022;56(9):989-995
Objective:To investigate the value of periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) in improving ability of demonstrating ocular masses on 3.0 T MR scanner.Methods:This study was a multi-center prospective study involving 6 centers. From July 2018 to January 2020, totally 413 patients with ocular masses from 6 centers were prospectively enrolled, and all of them underwent T 1WI and T 2WI, PROPELLER T 1 FLAIR and T 2WI, and contrast-enhanced scans. The signal intensity of eyelid, vitreous body, lacrimal gland, intraorbital segment of optic nerve, and orbital masses of eyelid, intraocular, lacrimal gland and retrobulbar were measured by two radiologists, and the signal to noise ratio (SNR) and contrast noise ratio (CNR) were calculated. The 5-point scoring method was used to evaluate the motion artefacts, tumor edges and the relationship between the tumor and adjacent structures, and the overall score of image quality was calculated. Paired t-test or Wilcoxon signed rank test was used to compare the image quality between PROPELLER and non-PROPELLER images. Results:The SNR and CNR of PROPELLER T 2WI were higher than those of non-PROPELLER T 2WI (all P<0.001). The SNR and CNR of PROPELLER T 1 FLAIR were lower than those of non-PROPELLER T 1WI (all P<0.05). The scores of artefacts and overall image quality in PROPELLER images were higher than those in non-PROPELLER images (all P<0.001). The tumor edge and the relationship between the tumor and adjacent structures scores of eyelid, intraocular, and lacrimal gland masses in PROPELLER images were higher than those in non-PROPELLER images (all P<0.001),while compared to non-PROPELLER images, retro-global masses in PROPELLER images showed no significant differences (all P>0.05). Conclusion:PROPELLER can reduce ocular motion artefacts, effectively improve image quality and ability of demonstrating anterior (eyelid, intraocular, and lacrimal gland) masses.