1.Quality Evaluation of Naomaili Granules Based on Multi-component Content Determination and Fingerprint and Screening of Its Anti-neuroinflammatory Substance Basis
Ya WANG ; Yanan KANG ; Bo LIU ; Zimo WANG ; Xuan ZHANG ; Wei LAN ; Wen ZHANG ; Lu YANG ; Yi SUN
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(2):170-178
ObjectiveTo establish an ultra-performance liquid fingerprint and multi-components determination method for Naomaili granules. To evaluate the quality of different batches by chemometrics, and the anti-neuroinflammatory effects of water extract and main components of Naomaili granules were tested in vitro. MethodsThe similarity and common peaks of 27 batches of Naomaili granules were evaluated by using Ultra performance liquid chromatography (UPLC) fingerprint detection. Ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) technology was used to determine the content of the index components in Naomaili granules and to evaluate the quality of different batches of Naomaili granules by chemometrics. LPS-induced BV-2 cell inflammation model was used to investigate the anti-neuroinflammatory effects of the water extract and main components of Naomaili granules. ResultsThe similarity of fingerprints of 27 batches of samples was > 0.90. A total of 32 common peaks were calibrated, and 23 of them were identified and assigned. In 27 batches of Naomaili granules, the mass fractions of 14 components that were stachydrine hydrochloride, leonurine hydrochloride, calycosin-7-O-glucoside, calycosin,tanshinoneⅠ, cryptotanshinone, tanshinoneⅡA, ginsenoside Rb1, notoginsenoside R1, ginsenoside Rg1, paeoniflorin, albiflorin, lactiflorin, and salvianolic acid B were found to be 2.902-3.498, 0.233-0.343, 0.111-0.301, 0.07-0.152, 0.136-0.228, 0.195-0.390, 0.324-0.482, 1.056-1.435, 0.271-0.397, 1.318-1.649, 3.038-4.059, 2.263-3.455, 0.152-0.232, 2.931-3.991 mg∙g-1, respectively. Multivariate statistical analysis showed that paeoniflorin, ginsenoside Rg1, ginsenoside Rb1 and staphylline hydrochloride were quality difference markers to control the stability of the preparation. The results of bioactive experiment showed that the water extract of Naomaili granules and the eight main components with high content in the prescription had a dose-dependent inhibitory effect on the release of NO in the cell supernatant. Among them, salvianolic acid B and ginsenoside Rb1 had strong anti-inflammatory activity, with IC50 values of (36.11±0.15) mg∙L-1 and (27.24±0.54) mg∙L-1, respectively. ConclusionThe quality evaluation method of Naomaili granules established in this study was accurate and reproducible. Four quality difference markers were screened out, and eight key pharmacodynamic substances of Naomaili granules against neuroinflammation were screened out by in vitro cell experiments.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Measuring Medical Waste from Gastrointestinal Endoscopies in South Korea to Estimate Their Carbon Footprint
Da Hyun JUNG ; Hyun Jung LEE ; Tae Joo JEON ; Young Sin CHO ; Bo Ra KANG ; Nae Sun YOUN ; Jae Myung CHA
Gut and Liver 2025;19(1):43-49
Background/Aims:
Although gastrointestinal endoscopy (GIE) is a major contributor to the carbon footprint of national healthcare, the amount of medical waste generated by GIE procedures is not reported in South Korea. This study aimed to measure the amount of medical waste generated from GIE procedures in South Korea.
Methods:
We conducted a 5-day audit of medical waste generated during GIEs at seven hospitals. During the study period, medical waste in the endoscopy examination rooms was measured twice daily and documented as mass (kg). To calculate the mean mass of disposable waste generated during one esophagogastroduodenoscopy (EGD) and one colonoscopy, the mean mass of medical waste generated from seven examinations was calculated. The mean mass of medical waste generated during GIEs was calculated by dividing the total mass of medical waste generated by the number of GIE procedures.
Results:
Overall, 3,922 endoscopies were performed and 4,558 kg of waste was generated. The mean weight of medical waste generated per endoscopy was 1.34 kg. Each EGD and colonoscopy generated a mean of 0.24 kg and 0.43 kg of disposable waste, respectively. Applying the mean waste estimates from this study to annual GIE procedures performed in South Korea in 2022 showed that the total medical waste produced from GIE was 13,704,453 kg. In addition, the total masses of medical waste produced during EGD and colonoscopy procedures were 819,766 kg and 2,889,478 kg, respectively.
Conclusions
Our quantitative measurement showed that a large amount of medical waste is generated from GIE procedures. However, further research is warranted to reduce medical waste generated during GIE, which is an urgent unmet need.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Measuring Medical Waste from Gastrointestinal Endoscopies in South Korea to Estimate Their Carbon Footprint
Da Hyun JUNG ; Hyun Jung LEE ; Tae Joo JEON ; Young Sin CHO ; Bo Ra KANG ; Nae Sun YOUN ; Jae Myung CHA
Gut and Liver 2025;19(1):43-49
Background/Aims:
Although gastrointestinal endoscopy (GIE) is a major contributor to the carbon footprint of national healthcare, the amount of medical waste generated by GIE procedures is not reported in South Korea. This study aimed to measure the amount of medical waste generated from GIE procedures in South Korea.
Methods:
We conducted a 5-day audit of medical waste generated during GIEs at seven hospitals. During the study period, medical waste in the endoscopy examination rooms was measured twice daily and documented as mass (kg). To calculate the mean mass of disposable waste generated during one esophagogastroduodenoscopy (EGD) and one colonoscopy, the mean mass of medical waste generated from seven examinations was calculated. The mean mass of medical waste generated during GIEs was calculated by dividing the total mass of medical waste generated by the number of GIE procedures.
Results:
Overall, 3,922 endoscopies were performed and 4,558 kg of waste was generated. The mean weight of medical waste generated per endoscopy was 1.34 kg. Each EGD and colonoscopy generated a mean of 0.24 kg and 0.43 kg of disposable waste, respectively. Applying the mean waste estimates from this study to annual GIE procedures performed in South Korea in 2022 showed that the total medical waste produced from GIE was 13,704,453 kg. In addition, the total masses of medical waste produced during EGD and colonoscopy procedures were 819,766 kg and 2,889,478 kg, respectively.
Conclusions
Our quantitative measurement showed that a large amount of medical waste is generated from GIE procedures. However, further research is warranted to reduce medical waste generated during GIE, which is an urgent unmet need.
7.Measuring Medical Waste from Gastrointestinal Endoscopies in South Korea to Estimate Their Carbon Footprint
Da Hyun JUNG ; Hyun Jung LEE ; Tae Joo JEON ; Young Sin CHO ; Bo Ra KANG ; Nae Sun YOUN ; Jae Myung CHA
Gut and Liver 2025;19(1):43-49
Background/Aims:
Although gastrointestinal endoscopy (GIE) is a major contributor to the carbon footprint of national healthcare, the amount of medical waste generated by GIE procedures is not reported in South Korea. This study aimed to measure the amount of medical waste generated from GIE procedures in South Korea.
Methods:
We conducted a 5-day audit of medical waste generated during GIEs at seven hospitals. During the study period, medical waste in the endoscopy examination rooms was measured twice daily and documented as mass (kg). To calculate the mean mass of disposable waste generated during one esophagogastroduodenoscopy (EGD) and one colonoscopy, the mean mass of medical waste generated from seven examinations was calculated. The mean mass of medical waste generated during GIEs was calculated by dividing the total mass of medical waste generated by the number of GIE procedures.
Results:
Overall, 3,922 endoscopies were performed and 4,558 kg of waste was generated. The mean weight of medical waste generated per endoscopy was 1.34 kg. Each EGD and colonoscopy generated a mean of 0.24 kg and 0.43 kg of disposable waste, respectively. Applying the mean waste estimates from this study to annual GIE procedures performed in South Korea in 2022 showed that the total medical waste produced from GIE was 13,704,453 kg. In addition, the total masses of medical waste produced during EGD and colonoscopy procedures were 819,766 kg and 2,889,478 kg, respectively.
Conclusions
Our quantitative measurement showed that a large amount of medical waste is generated from GIE procedures. However, further research is warranted to reduce medical waste generated during GIE, which is an urgent unmet need.
8.Measuring Medical Waste from Gastrointestinal Endoscopies in South Korea to Estimate Their Carbon Footprint
Da Hyun JUNG ; Hyun Jung LEE ; Tae Joo JEON ; Young Sin CHO ; Bo Ra KANG ; Nae Sun YOUN ; Jae Myung CHA
Gut and Liver 2025;19(1):43-49
Background/Aims:
Although gastrointestinal endoscopy (GIE) is a major contributor to the carbon footprint of national healthcare, the amount of medical waste generated by GIE procedures is not reported in South Korea. This study aimed to measure the amount of medical waste generated from GIE procedures in South Korea.
Methods:
We conducted a 5-day audit of medical waste generated during GIEs at seven hospitals. During the study period, medical waste in the endoscopy examination rooms was measured twice daily and documented as mass (kg). To calculate the mean mass of disposable waste generated during one esophagogastroduodenoscopy (EGD) and one colonoscopy, the mean mass of medical waste generated from seven examinations was calculated. The mean mass of medical waste generated during GIEs was calculated by dividing the total mass of medical waste generated by the number of GIE procedures.
Results:
Overall, 3,922 endoscopies were performed and 4,558 kg of waste was generated. The mean weight of medical waste generated per endoscopy was 1.34 kg. Each EGD and colonoscopy generated a mean of 0.24 kg and 0.43 kg of disposable waste, respectively. Applying the mean waste estimates from this study to annual GIE procedures performed in South Korea in 2022 showed that the total medical waste produced from GIE was 13,704,453 kg. In addition, the total masses of medical waste produced during EGD and colonoscopy procedures were 819,766 kg and 2,889,478 kg, respectively.
Conclusions
Our quantitative measurement showed that a large amount of medical waste is generated from GIE procedures. However, further research is warranted to reduce medical waste generated during GIE, which is an urgent unmet need.
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.Differences and Mechanisms of Combined Use of "Raw and Fried Ziziphi Spinosae Semen" in Anmeidan and Its Disassembled Prescriptions in Improving Anxiety and Cognitive Impairment in Insomnia Rat Model Based on Serum Metabolomics
Kang SUN ; Bo XU ; Zijing YE ; Miao ZHU
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(10):36-43
ObjectiveTo investigate the differences in efficacy and endogenous metabolic mechanisms of Anmeidan with combined use of raw and fried Ziziphi Spinosae Semen and its disassembled prescriptions in treating anxiety and cognitive impairment in insomnia rats. MethodsSixty rats were randomly divided into six groups (n=10 per group): blank group, model group, suvorexant group (30 mg·kg-1), Anmeidan group (9.09 g·kg-1), Anmeidan with absence of raw Ziziphi Spinosae Semen group (7.38 g·kg-1), and Anmeidan with absence of fried Ziziphi Spinosae Semen group (7.38 g·kg-1). An insomnia model was constructed by intraperitoneal injection of para-chlorophenylalanine (PCPA), followed by gavage administration of Anmeidan or its disassembled prescriptions. Anxiety levels were assessed using the open field test, while cognitive ability was evaluated via the novel object recognition test. The pathological morphology of hippocampal neurons was examined using electron microscopy. Serum samples were analyzed by ultra-performance liquid chromatography-quadrupole time-of-flight mass spectrometry (UPLC-Q-TOF-MS) for principal component analysis, metabolic profiling, identification of differential metabolites, and metabolic pathway analysis. ResultsCompared with the blank group, the model group exhibited significantly increased exercise mileage, exercise time, and the ratio of the number of entries into the peripheral zone to the total number of entries into both the peripheral and central zones exhibited a marked increase (P<0.05, P<0.01), while the novel object recognition index significantly decreased (P<0.05). Compared with the model group, the Anmeidan and suvorexant groups showed significantly reduced exercise mileage and exercise time (P<0.01). The ratio of the number of entries into the peripheral zone to the total number of entries into both the peripheral and central zones decreased (P<0.05), and a significant increase in the novel object recognition index (P<0.01). However, the disassembled prescription groups showed no significant improvement in open field test and novel object recognition test indices. Electron microscopy revealed that the Anmeidan group improved the pathological morphology of hippocampal neurons in insomnia rats. Metabolomics analysis identified 10 potential differential metabolites associated with Anmeidan's therapeutic effects, involving metabolic pathways related to phenylalanine and tryptophan biosynthesis and metabolism, as well as the serotonergic pathway. ConclusionThe combined use of raw and fried Ziziphi Spinosae Semen in Anmeidan is more effective than its disassembled prescriptions in alleviating anxiety and cognitive impairment in PCPA-induced insomnia rats. The underlying mechanism may be associated with metabolic pathways related to phenylalanine, tryptophan, and serotonin.

Result Analysis
Print
Save
E-mail