1.Particle evaluation of cardiovascular stents.
Xiujuan ZHANG ; Feng LIN ; Jing JIA ; Bo DING ; Yong LI ; Jiahua HUANG
Chinese Journal of Medical Instrumentation 2014;38(2):126-129
This paper has briefly introduced the definition, classification, harms, sources and control of particles, lists the particle evaluation method of coronary stents. And the development trend of particle evaluation method of coronary stents is also analyzed.
Biocompatible Materials
;
adverse effects
;
Blood Vessel Prosthesis
;
Coronary Artery Disease
;
therapy
;
Humans
;
Particle Size
;
Stents
2.Current Strategies of Surface Modifications to Polyurethane Biomaterials for Vascular Grafts.
Huai-Gu HUANG ; Tao XIANG ; Yue-Xin CHEN
Chinese Medical Sciences Journal 2023;38(4):279-285
As the number of patients suffering from cardiovascular diseases and peripheral vascular diseases rises, the constraints of autologous transplantation remain unavoidable. As a result, artificial vascular grafts must be developed. Adhesion of proteins, platelets and bacteria on implants can result in stenosis, thrombus formation, and postoperative infection, which can be fatal for an implantation. Polyurethane, as a commonly used biomaterial, has been modified in various ways to deal with the adhesions of proteins, platelets, and bacteria and to stimulate endothelium adhesion. In this review, we briefly summarize the mechanisms behind adhesions, overview the current strategies of surface modifications of polyurethane biomaterials used in vascular grafts, and highlight the challenges that need to be addressed in future studies, aiming to gain a more profound understanding of how to develop artificial polyurethane vascular grafts with an enhanced implantation success rate and reduced side effect.
Humans
;
Polyurethanes
;
Biocompatible Materials
;
Blood Vessel Prosthesis/adverse effects*
;
Cardiovascular Diseases
3.Establishment of contralateral arteriovenous fistula by using the waste vein on the side of central venous lesion: a case report.
Xue Dong BAO ; Ya Xue SHI ; Min YU ; Si Jie LIU ; Lan Hua MI ; Chang WU ; Wen Ping HU
Chinese Journal of Hepatology 2023;39(1):36-38
Central venous lesion is a difficult problem in the vascular access complications of hemodialysis, which can cause serious clinical symptoms and affect the quality of hemodialysis and life of patients. We established arteriovenous fistula of the contralateral graft blood vessel with the used vein on the diseased side of the central vein of the patient. The arteriovenous fistula of the graft blood vessel was successfully punctured and hemodialysis was performed 2 weeks later. In this way, we not only solved the problem of venous hypertension and subsequent vascular access in the patient, but also reserved more vascular resources.
Humans
;
Arteriovenous Shunt, Surgical/adverse effects*
;
Blood Vessel Prosthesis Implantation
;
Treatment Outcome
;
Renal Dialysis
;
Arteriovenous Fistula
4.Clinical Analysis of the Treatment of Iliac Limb Occlusion Following Endovascular Abdominal Aortic Aneurysm Repair.
Jiang SHAO ; Zhi-Chao LAI ; Xiao-Jun SONG ; Zhi-Li LIU ; Rong ZENG ; Yue-Xin CHEN ; Yue-Hong ZHENG ; Bao LIU
Acta Academiae Medicinae Sinicae 2021;43(6):917-921
Objective To explore the cause and the treatment strategies of iliac limb occlusion after endovascular abdominal aortic aneurysm repair(EVAR). Methods The patients receiving EVAR in PUMC Hospital from January 2015 to December 2020 were retrospectively analyzed.Sixteen(2.7%)cases of iliac limb occlusion were identified,among which 6,9,and 1 cases underwent surgical bypass,endovascular or hybrid procedure,and conservative treatment,respectively. Results Fifteen cases were successfully treated.During the 10.6-month follow-up,2 cases receiving hybrid treatment underwent femoral-femoral bypass due to re-occlusion of the iliac limb. Conclusions Iliac limb occlusion mostly occurs in the acute phase after EVAR,and endovascular or hybrid treatment can be the first choice for iliac limb occlusion.It is suggested to focus on the risk factors for prevention.
Aortic Aneurysm, Abdominal/surgery*
;
Blood Vessel Prosthesis
;
Blood Vessel Prosthesis Implantation/adverse effects*
;
Endovascular Procedures
;
Humans
;
Iliac Artery/surgery*
;
Retrospective Studies
;
Risk Factors
;
Stents
;
Treatment Outcome
6.Emergency endovascular repair of iliac artery rupture caused by post-stenting angioplasty with an endograft.
Yu-bin ZHOU ; Dan-ming WU ; Ke XU ; Cheng-gang WANG ; Wei YI ; Qi JIA ; Yu-xin SUN
Chinese Journal of Traumatology 2007;10(1):63-64
Iliac artery rupture is a rare complication of post-stenting angioplasty and can lead to massive life-threatening haemorrhage. Conventional surgery can not repair the damaged vessel easily and may cause substantial blood loss and high operative morbidity and mortality. We report our experience with a self-expanding covered endoprosthesis for endovascular repair of the rupture of an iliac artery caused by stenting angioplasty.
Aged, 80 and over
;
Angioplasty
;
adverse effects
;
Blood Vessel Prosthesis Implantation
;
adverse effects
;
Endarterectomy
;
Female
;
Humans
;
Iliac Artery
;
injuries
;
Rupture
;
Stents
7.An elephant trunk stent graft strayed into the false lumen leading to a death during the Sun's operation: A case report.
Fushuo ZHOU ; Hong CHAI ; Ruisheng LIU ; Bing SONG
Journal of Central South University(Medical Sciences) 2021;46(2):217-220
Type A aortic dissection (AD) is a critical and severe disease with high mortality. The Sun's operation is a standard surgical method for this kind of disease at present. For the procedure, an elephant trunk stent is inserted into the true lumen of the descending aorta and the aortic arch is replaced. A patient was admitted to the First Hospital of Lanzhou University due to sudden chest and back pain for 6 days. Computed tomography angiography (CTA) showed type A AD. Ascending aorta replacement, Sun's operation, and ascending aorta to right femoral artery bypass grafting were performed. After surgery, the patient's condition was worsened. The digital subtraction angiography (DSA) showed the elephant trunk stent was inserted into the false lumen of AD, leading to the occlusion of the large blood vessel at the distal part of the abdominal aorta and below. Although we performed intima puncture and endovascular aortic repair, the patient was still dead.
Aneurysm, Dissecting/surgery*
;
Aorta, Abdominal
;
Aorta, Thoracic/surgery*
;
Blood Vessel Prosthesis Implantation/adverse effects*
;
Humans
;
Stents/adverse effects*
;
Treatment Outcome
8.Calcification Comparison of Polymers for Vascular Graft.
Jong Chul PARK ; Min Jung SONG ; Yu Shik HWANG ; Hwal SUH
Yonsei Medical Journal 2001;42(3):304-310
Polytetrafluoroethylene (PTFE), polyurethane (PU) and silicone are widely known biocompatible polymers which are commonly used for vascular grafts. However, in vitro and in vivo calcifications of these polymers have been found to seriously compromise their quality as biomaterials. In consideration of this problem, the present study compared the calcification rate and extent of PTFE, PU and silicone. Using the in vitro flow-type method, PTFE, PU and silicone films were tested for 1, 4, 7, 10, 14 and 21 days. After 21 days of in vitro calcification test, the calcium levels on PTFE, PU and silicone were 35.89 5.01 microgram /cm2, 23.73 0.68 microgram/cm2 and 19.86 5.28 microgram/cm2, respectively. The higher observed calcium level for PTFE may be due to the effect of the rough surface of PTFE in accumulating calcium ions on the polymer surface. From the 7th day of test, the [Ca]/[P] molar ratio started to decrease over time, and PTFE showed a faster calcification process. This decreasing [Ca]/[P] molar ratio demonstrated the typical calcification mechanism consisting of phosphorus ion accumulation following calcium ion accumulation. This study concluded that PU and silicone are less calcified than PTFE film, a finding in good agreement with previously published studies.
Biocompatible Materials/*adverse effects
;
*Blood Vessel Prosthesis
;
Calcinosis/*etiology
;
Comparative Study
;
Microscopy, Electron, Scanning
;
Polytetrafluoroethylene/*adverse effects
;
Polyurethanes/*adverse effects
;
Silicones/*adverse effects
9.The relationship between the characteristics of tears and the progression of Stanford type B aortic dissection after endovascular treatment.
Peng Fei YUAN ; Ming Wei WU ; Hai Bo WANG ; Jiang XIONG
Chinese Journal of Surgery 2023;61(3):256-259
Endovascular treatment of Stanford type B aortic dissection (type B dissection) has been widely used. There will be complications such as aortic dilatation, which will lead to poor prognosis of some patients. With more in-depth researches, it was found that there was a possible correlation between the prognosis of type B dissection and tears, such as the increasing of aortic diameter would be faster with longer tears, and the location of the tear will affect the thrombosis of the false lumen. Studies on hemodynamics have also found that different characteristics of tears of aortic dissection can cause changes in the pressure, blood flow rate and blood capacity in the true and false lumens recently. The hemodynamic changes can be used to predict the prognosis of type B dissection. The main characteristics of tears included the size, position, number of tears, residual tears and stent graft induced new entry. Describing the effect of tear characteristics on the development of type B dissection, can provide the basis for the clinical treatment and further research of type B dissection.
Humans
;
Aortic Dissection/surgery*
;
Hemodynamics
;
Prognosis
;
Blood Vessel Prosthesis Implantation/adverse effects*
;
Thrombosis/etiology*
;
Endovascular Procedures/adverse effects*
;
Aortic Aneurysm, Thoracic/surgery*
;
Stents/adverse effects*
;
Treatment Outcome
10.How to do well at endovascular repairing of abdominal aortic aneurysm.
Chinese Journal of Surgery 2007;45(23):1587-1589