1.Protective effect of vascular endothelial growth factor B on retinal nerve cells
Xin SUN ; Lei ZHANG ; Honglian GAO ; Shoukuan ZHANG ; Jun JIANG
International Eye Science 2025;25(7):1089-1093
The retina has a complex and delicate function and structure, containing a large number of neuronal cells with extremely limited regenerative capacity, which are susceptible to damage and apoptosis under pathological conditions such as ischemia and hypoxia, resulting in irreversible vision loss. Retinal diseases are very common, such as retinitis pigmentosa(RP), age-related macular degeneration(ARMD), diabetic retinopathy(DR), and glaucoma. Most of the diseases in this category are treated symptomatically, which is effective but has some limitations in neuroprotection. Vascular endothelial growth factor(VEGF)-B is functionally relatively inert in the VEGF family, and unlike pro-angiogenic VEGF-A, VEGF-B shows functional inertia in angiogenesis but exhibits significant neuroprotective effects. VEGF-B is a potent anti-apoptotic, antioxidant factor that can regulate the expression of apoptotic genes and enhance the expression of glutamic acid decarboxylase 1 by binding to VEGFR-1 to activate the ERK1/2 or Akt pathway, in addition to decreasing the expression of glutamate, resulting in retinal neuroprotective effects. In this article, the protective effects of VEGF-B on retinal neuronal cells were reviewed to provide new ideas for the treatment of retina-associated diseases.
2.Comparative study on changes in forefoot width after minimally invasive extra-articular osteotomy via small incision for hallux valgus.
Yang ZHANG ; Yanrong YUAN ; Dehai KONG ; Ying LIU ; Guangchao SUN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(2):140-145
OBJECTIVE:
To compare the difference in forefoot width between minimally invasive extra-articular osteotomy via small incision and traditional Chevron osteotomy in the treatment of hallux valgus.
METHODS:
A retrospective analysis was conducted on the clinical data of 45 patients with hallux valgus between April 2019 and July 2022. Among them, 22 cases underwent minimally invasive extra-articular osteotomy via small incision (minimally invasive group), and 23 cases underwent traditional Chevron osteotomy (traditional group). There was no significant difference in the baseline data between the two groups ( P>0.05), including gender, age, affected side, Mann classification of hallux valgus, disease duration, and preoperative intermetatarsal angle (IMA), hallux valgus angle (HVA), distal metatarsal articular angle (DMAA), bony forefoot width, soft tissue forefoot width, osteophyte width, and American Orthopaedic Foot and Ankle Society (AOFAS) score. The osteotomy healing time and the occurrence of complications in the two groups were recorded. The differences between pre- and post-operation (changes) in various imaging indicators and AOFAS scores in the two groups were calculated. And the bony forefoot width and soft tissue forefoot width at 1, 6, and 12 months after operation were also recorded and compared between the two groups.
RESULTS:
One case of skin injury occurred during operation in the minimally invasive group, while 3 cases of poor wound healing occurred after operation in the traditional group. None of the patients experienced infections, nerve injuries, or other complications. All patients were followed up 12-31 months (mean, 22.5 months). The osteotomy healed in the two groups and no significant difference in healing time between the two groups was found ( P>0.05). The IMA, HVA, DMAA, osteophyte width, and AOFAS score at 12 months after operation significantly improved compared to those before operation ( P<0.05). There was no significant difference between the two groups in the changes of IMA, HVA, and osteophyte width ( P>0.05). However, the differences in the changes of AOFAS score and DMAA were significant ( P<0.05). There was no significant difference between the two groups in bony and soft tissue forefoot widths at different time points after operation ( P>0.05). However, there were significant differences in the two groups between the pre- and post-operation ( P<0.05).
CONCLUSION
The minimally invasive extra-articular osteotomy via small incision for hallux valgus, despite not removing the medial osteophyte of the first metatarsal, can still effectively improve the forefoot width and osteophyte width. While correcting the IMA and HVA, it can more effectively restore the DMAA, resulting in better AOFAS scores.
Humans
;
Hallux Valgus/surgery*
;
Osteotomy/methods*
;
Male
;
Female
;
Minimally Invasive Surgical Procedures/methods*
;
Retrospective Studies
;
Middle Aged
;
Forefoot, Human/pathology*
;
Adult
;
Treatment Outcome
;
Aged
3.Effectiveness of spring ligament repair in treatment of children's flexible flatfoot.
Rongzhi JIA ; Yang ZHANG ; Yongjie ZHAO ; Ying LIU ; Guangchao SUN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(4):406-411
OBJECTIVE:
To investigate the effectiveness of spring ligament repair combined with subtalar arthroereisis (STA) and the Kidner procedure for treating children's flexible flatfoot with painful accessory navicular.
METHODS:
A retrospective analysis was conducted on clinical data from 45 children (45 feet) aged 7-14 years with flexible flatfoot and painful accessory navicular who met the selection criteria and were treated between February 2018 and May 2022. Among them, 23 cases (23 feet) were treated with spring ligament repair combined with STA and Kidner procedure (observation group), while 22 cases (22 feet) received STA with Kidner procedure alone (control group). Comparison of baseline data between the two groups including gender, age, affected side, preoperative visual analogue scale (VAS) score, American Orthopaedic Foot & Ankle Society (AOFAS) score, talonavicular coverage angle (TCA), talus-first metatarsal angle (T1MT), talus-second metatarsal angle (T2MT), talus first plantar angle (Meary angle), calcaneal inclination angle (Pitch angle) showed no significant differences ( P>0.05). The following parameters were recorded and compared between the two groups: operation time, intraoperative blood loss, incision length, hospital stay, time to full weight-bearing, and complication rates. Foot pain and functional recovery were assessed using the VAS score and AOFAS score preoperatively and at last follow-up. Radiographic measurements including TCA, T1MT, T2MT, Meary angle, and Pitch angle were analyzed by comparing preoperative to last follow-up values.
RESULTS:
Both groups of patients successfully completed the surgery without any procedure-related complications such as vascular, neural, or tendon injury. The operation time in the observation group was significantly longer than that in the control group ( P<0.05). There was no significant difference between the two groups in terms of intraoperative blood loss, incision length, hospital stay, or time to full weight-bearing ( P>0.05). All patients were followed up 23-47 months (mean, 33.7 months). In the control group, 1 patient experienced discomfort during walking, attributed to screw irritation in the sinus tarsi, which resolved after 2-3 months of rehabilitation. None of the remaining patients developed complications such as sinus tarsi screw loosening, peroneal tendon contracture, or wound infection. At last follow-up, the observation group showed significantly better improvements in radiographic parameters (TCA, T1MT, T2MT, Meary angle, Pitch angle) and greater reductions in VAS and AOFAS scores compared to the control group ( P<0.05).
CONCLUSION
The combined procedure of spring ligament repair, STA, and Kidner procedure for children's flexible flatfoot with painful accessory navicular demonstrates significant improvements in foot appearance, arch collapse correction, and pain relief. This technique offers technical simplicity, minimal intraoperative complications, and satisfactory clinical outcomes.
Humans
;
Flatfoot/surgery*
;
Child
;
Retrospective Studies
;
Adolescent
;
Male
;
Female
;
Treatment Outcome
;
Tarsal Bones/abnormalities*
;
Subtalar Joint/surgery*
;
Ligaments, Articular/surgery*
;
Orthopedic Procedures/methods*
;
Foot Diseases
4.Research progress on the potential mechanisms and effects of the cholinergic anti-inflammatory pathway in sepsis.
Chinese Critical Care Medicine 2025;37(4):397-401
Sepsis is a common clinical syndrome in intensive care unit (ICU) with high morbidity and high mortality, making it a global health issue. The estimated global incidence of sepsis is 437/100 000, with an in-hospital mortality of 17%, which is higher in developing countries and underdeveloped regions. Despite some progress in sepsis treatment in recent years, the complexity of its pathophysiology limits therapeutic effectiveness. The cholinergic anti-inflammatory pathway (CAP), a neuro-immune regulatory pathway, plays a crucial role in sepsis through key components such as the vagus nerve, central M-type muscarinic receptor, the spleen and splenic sympathetic nerves, acetylcholine, and the α7 subunit of the nicotinic acetylcholine receptor (α7nAChR). This article explores the potential mechanisms and roles of CAP in sepsis, focusing on CAP-related cell signaling pathways, including nuclear factor-κB (NF-κB) signaling pathway, Janus kinase/signal transducer and activator of transcription 3 (JAK/STAT3) signaling pathway, phosphatidylinositol 3-kinase/protein kinase B (PI3K/Akt) signaling pathway, and cyclooxygenase (COX) and prostaglandin E2 (PGE2) signaling pathways. Potential applications of CAP in sepsis treatment include stimulating the vagus nerve (e.g., through pharmacological, electrical, or acupuncture stimulation), using α7nAChR agonists (e.g., nicotine, GTS-21, and PNU-282987), adrenergic receptor agonists (e.g., dexmedetomidine and salbutamol), or other drugs and bioactive substances (e.g., buprenorphine and traditional Chinese medicine components). These approaches aim to activate CAP, suppress inflammatory responses, and improve sepsis prognosis, providing a theoretical basis for treatment and promoting the development of related drugs.
Sepsis/metabolism*
;
Humans
;
Signal Transduction
;
alpha7 Nicotinic Acetylcholine Receptor
;
NF-kappa B/metabolism*
;
Anti-Inflammatory Agents
;
Acetylcholine
5.Type Ⅱ endoleak originating from inferior mesenteric artery after endovascular abdominal aortic aneurysm repair: A retrospective analysis in a single center
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(10):1462-1466
Objective To investigate the management experience of type Ⅱ endoleak originating from inferior mesenteric artery (IMA) after endovascular abdominal aortic aneurysm repair (EVAR). Methods The clinical data of patients with type Ⅱ endoleak originating from IMA after EVAR treated in the Department of Vascular Surgery, Shandong Provincial Hospital Affiliated to Shandong First Medical University from October 2016 to November 2021 were collected and analyzed. Results There were 12 males and 3 females at age of 57-89 (68.00±7.84) years. Eleven patients received embolization of the abdominal aortic aneurysm lumen and initial segment of the IMA via the superior mesenteric artery-middle colic artery-Riolan arch-left colic artery-IMA route. Three patients received embolization of the initial segment of the IMA by the above route. One patient underwent open dissection of the abdominal aortic aneurysm, and orifice of IMA was sutured in the aneurysm cavity while stents were retained. All 15 patients were successfully treated by surgery. The symptoms of back pain, abdominal pain and abdominal distension disappeared in 6 patients after surgery. Neither perioperative deaths nor complications happened during the treatment and follow-up period. The median follow-up time was 11.00 (9.00, 18.00) months. Two patients with typeⅡendoleak recurred during the follow-up period and were admitted to hospital for secondary embolization. No recurrence was observed at 12 months postoperative follow-up. Conclusion Type Ⅱ endoleak is one of the most common complications after EVAR. IMA is the most common criminal origin of typeⅡendoleak. TypeⅡendoleak that lead to persistent expansion of the aneurysm cavity requires aggressive intervention.
6.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
7.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
8.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
9.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
10.Effects of Anterior Cruciate Ligament Reconstruction Timing on Post-Operative Motor Performance and Proprioception.
Xiang-Yi WANG ; Jing-Yi SUN ; Chen HE ; Yi QIAN ; Sen GUO ; Xiao-Han ZHANG ; Hao XU ; Zhuang LIU ; Ya-Wei GONG ; Lei LI ; Ming-Ze LIU ; Feng GAO ; Jing-Bin ZHOU
Acta Academiae Medicinae Sinicae 2024;46(6):797-804
Objective To evaluate the effects of anterior cruciate ligament (ACL) reconstruction timing on the motor performance and proprioception by clinical evaluation as well as proprioception and motor performance tests on the patients more than 2 years after ACL reconstruction. Methods The patients who underwent ACL reconstruction in the National Institute of Sports Medicine,General Administration of Sport of China from January 2015 to January 2021 and met the inclusion criteria were followed up,and the postoperative data were collected retrospectively.Fifty-six patients who met the inclusion criteria were included in this study and categorized into two groups:early surgery (n=28,who underwent ACL reconstruction ≤3 weeks after injury) and delayed surgery (n=28,who underwent ACL reconstruction >3 weeks after injury).The basic information,clinical evaluation results,proprioception,and motor performance were compared between the two groups. Results The ACL return to sport after injury scale (ACL-RSI) score in the early surgery group was higher than that in the delayed surgery group [(68.68±22.04)scores vs. (55.82±24.87)scores,P=0.045].There was no difference in the range of motion of the knee joint,the positive rate of pivot shift test,or the scores of Tegner,Marx,Lysholm,knee injury and osteoarthritis outcome score (KOOS),and international knee documentation committee (IKDC) between the two groups (all P>0.05).Although there was no significant difference in range of motion of the knee joint between the two groups,the proportion of knee flexion and extension affected in the early surgery group was smaller than that in the delayed surgery group.Neither motor performance (isokinetic strength test,Y-balance test,and single-leg jump test) nor proprioception had difference between the two groups (all P>0.05). Conclusions Early ACL reconstruction outperformed delayed ACL reconstruction in improving the psychological health,emotions,and confidence in returning to sport,accelerating functional recovery of the patients.The timing of ACL reconstruction has no significant effect on the short-term postoperative knee stability,knee function,motor performance,or proprioceptive recovery of the patients.Early ACL reconstruction is recommended for improving the clinical outcomes.
Humans
;
Anterior Cruciate Ligament Reconstruction/methods*
;
Proprioception/physiology*
;
Retrospective Studies
;
Male
;
Female
;
Range of Motion, Articular
;
Anterior Cruciate Ligament Injuries/physiopathology*
;
Adult
;
Postoperative Period
;
Time Factors
;
Return to Sport
;
Recovery of Function
;
Knee Joint/physiopathology*
;
Young Adult

Result Analysis
Print
Save
E-mail