1.Design of Dyson Flow Cytometry System.
Xiaoliang ZHANG ; Bidou WANG ; Gangyin LUO
Chinese Journal of Medical Instrumentation 2019;43(4):270-274
In order to meet the needs of the flow cytometry for the simultaneous analysis of multiple fluorescence wavelengths and small volume, the design method of flow cytometry spectrum analysis system is presented by analyzing the characteristics of Dyson structure. And according to the method, a flow cytometry spectrum analysis system is disigned with Dyson type.The system's spectral range is 400 nm to 800 nm, the defocused spot size is less than the pixel size 24μ mm, the ransfer function value is above 0.8 at the Nyquist cut-off frequency 21 lp/mm,the spectral resolution is less than 3 nm, and the overall size is 83.54 mm×85.60 mm.The system has good optical performance and small volume, which meets the needs of the flow cytometry fluorescence spectral analysis. The outstanding innovation of this system is the application of Dyson light splitting structure and EMCCD detector which is high speed and high sensitivity.
Equipment Design
;
Flow Cytometry
;
instrumentation
2.Design of a dynamic measurement system for Bl factor spatial distribution of resonant blood viscoelastic sensor.
Jun QIAN ; Haixuan SUN ; Bidou WANG
Journal of Biomedical Engineering 2023;40(5):965-972
Bl factor is a key system parameter of the resonant blood viscoelastic sensor. In this paper, a dynamic measurement system for the spatial distribution of Bl factor based on velocity amplitude and motional impedance was designed. The system extracted the velocity amplitude and motional impedance of the coil under the dynamic condition of driving the sensor to generate simple harmonic oscillations using laser displacement and impedance analysis combined with in-phase/quadrature demodulation algorithm, and controlled the equilibrium position of the coil by adjusting the direct current component of the excitation current to realize the position scanning. In the position interval of [-240, 240] μm, the maximum coefficient of variation of the measurement results was 0.077 3%, and the maximum relative error to the simulation results was 2.937 9%, with a linear fitting correlation coefficient R 2 = 0.996 8. The system can be used to accurately measure the spatial distribution of Bl factor of the resonant blood viscoelastic sensor, which provides a technical support for the verification of the design of the sensor magnetic circuit.
Computer Simulation
;
Electric Impedance
;
Motion
;
Algorithms
;
Lasers
3.Design and experiment of online monitoring system for long-term culture of embryo.
Weijun ZENG ; Zhenying ZHAO ; Yuchen YANG ; Minchao ZHOU ; Bidou WANG ; Haixuan SUN
Journal of Biomedical Engineering 2021;38(6):1134-1143
In the study of embryo development process, the morphological features at different stages are essential to evaluate developmental competence of the embryo, which can be used to optimize and improve the system for
Blastocyst
;
Embryo Culture Techniques
;
Embryonic Development
;
Fertilization in Vitro