1.A makeshift blue light filter for endoscopic identification of traumatic cerebrospinal fluid leak using fluorescein.
Bianca Denise E. EDORA ; Ryan U. CHUA ; Patrick Joseph L. ESTOLANO
Philippine Journal of Otolaryngology Head and Neck Surgery 2022;37(2):46-49
Objective:
To describe a makeshift blue light filter for endoscopic visualization of a traumatic cerebrospinal fluid leak repair using intrathecal fluorescein and its application in one patient.
Methods:
Study Design:Surgical Instrumentation
Setting:Tertiary Government Training Hospital
Patient:One
Results:
Intra-operative endoscopic identification of fistulae sites was achieved using intrathecal injection of fluorescein that fluoresced using our makeshift blue light filter in a 43-year-old man who presented with a 3-month history of rhinorrhea due to skull base fractures along with multiple facial and upper extremity fractures he sustained after a fall from a standing height of 6 feet. He underwent transnasal endoscopic repair of cerebrospinal fluid fistulae in the planum sphenoidale, clivus and sellar floor. Post-operatively, there was complete resolution of rhinorrhea with no complications noted.
Conclusion
Our makeshift blue light filter made from readily available materials may be useful for endoscopic identification of CSF leaks using fluorescein in a low- to middle-income country setting like ours.
Human
;
Male
;
Adult (a Person 19-44 Years Of Age)
;
Skull Fracture, Basilar
;
Cranial Fossa, Posterior