1.Biocompatibility of two experimental scaffolds for regenerative endodontics.
Dephne Jack Xin LEONG ; Frank C SETZER ; Martin TROPE ; Bekir KARABUCAK
Restorative Dentistry & Endodontics 2016;41(2):98-105
OBJECTIVES: The biocompatibility of two experimental scaffolds for potential use in revascularization or pulp regeneration was evaluated. MATERIALS AND METHODS: One resilient lyophilized collagen scaffold (COLL), releasing metronidazole and clindamycin, was compared to an experimental injectable poly(lactic-co-glycolic) acid scaffold (PLGA), releasing clindamycin. Human dental pulp stem cells (hDPSCs) were seeded at densities of 1.0 × 10(4), 2.5 × 10(4) and 5.0 × 10(4). The cells were investigated by light microscopy (cell morphology), MTT assay (cell proliferation) and a cytokine (IL-8) ELISA test (biocompatibility). RESULTS: Under microscope, the morphology of cells coincubated for 7 days with the scaffolds appeared healthy with COLL. Cells in contact with PLGA showed signs of degeneration and apoptosis. MTT assay showed that at 5.0 × 10(4) hDPSCs, COLL demonstrated significantly higher cell proliferation rates than cells in media only (control, p < 0.01) or cells co-incubated with PLGA (p < 0.01). In ELISA test, no significant differences were observed between cells with media only and COLL at 1, 3, and 6 days. Cells incubated with PLGA expressed significantly higher IL-8 than the control at all time points (p < 0.01) and compared to COLL after 1 and 3 days (p < 0.01). CONCLUSIONS: The COLL showed superior biocompatibility and thus may be suitable for endodontic regeneration purposes.
Apoptosis
;
Cell Proliferation
;
Clindamycin
;
Collagen
;
Dental Pulp
;
Endodontics*
;
Enzyme-Linked Immunosorbent Assay
;
Humans
;
Interleukin-8
;
Metronidazole
;
Microscopy
;
Regeneration
;
Stem Cells
2.A comparison of dimensional standard of several nickel-titanium rotary files.
Ki Won KIM ; Kyung Mo CHO ; Se Hee PARK ; Ki Yeol CHOI ; Bekir KARABUCAK ; Jin Woo KIM
Restorative Dentistry & Endodontics 2014;39(1):7-11
OBJECTIVES: The aim of this study was to compare the dimensional standard of several nickel-titanium (Ni-Ti) rotary files and verify the size conformity. MATERIALS AND METHODS: ProFile (Dentsply Maillefer), RaCe (FKG Dentaire), and TF file (SybronEndo) #25 with a 0.04 and 0.06 taper were investigated, with 10 in each group for a total of 60 files. Digital images of Ni-Ti files were captured under light microscope (SZX16, Olympus) at 32x. Taper and diameter at D1 to D16 of each files were calculated digitally with AnalySIS TS Materials (OLYMPUS Soft Imaging Solutions). Differences in taper, the diameter of each level (D1 to D16) at 1 mm interval from (ANSI/ADA) specification No. 101 were statistically analyzed using one-way ANOVA and Scheffe's post-hoc test at 95% confidence level. RESULTS: TF was the only group not conform to the nominal taper in both tapers (p < 0.05). All groups except 0.06 taper ProFile showed significant difference from the nominal diameter (p < 0.05). CONCLUSIONS: Actual size of Ni-Ti file, especially TF, was different from the manufacturer's statements.
Continental Population Groups
;
Humans