1.Protective effect of micro needle array drug delivery technology on the blood vessel of arteriovenous fistula
Beili CAO ; Jing HU ; Guobing YANG ; Yi HU ; Binhong YAN
Clinical Medicine of China 2017;33(3):205-209
Objective To investigate the protective effect of mucopolysaccharide polysulfate cream(MPC) and micro needle array drug delivery technologarray(MNADDT) on the blood vessel of arteriovenous fistula.Methods Eighty cases maintenance hemodialysis patients with autogenous arteriovenous fistula were randomly divided into control group(with the treatment of MPC) and study group(with the treatment of MPC plus MNADDT),40 patients in each group.Both groups were studied for the duration of 12 months.The vascular complications of puncture pain sense,puncture failure times,phlebitis,hardening of the arteries,internal fistula stenosis or embolism,pseudoaneurysm,swollen hands comprehensive syndrome of two groups were observed,and the changes of arteriovenous fistula blood flow,blood vessel diameter by Doppler ultrasound were observed in the two groups for 12 months.Results (1)The incidence of puncture pain(2.71±0.11 vs.2.76±0.14,t=2.21,P<0.05),puncture failure times(38 times vs.73 times,χ2=11.425,P<0.05),phlebitis(2 cases vs.8 cases,χ2=4.341,P<0.05) and blood vessel sclerosis(2 cases vs.9 cases,χ2=5.446,P<0.05) of the treatment group were significantly lower than that of the control group during the study(P<0.05).(2)Blood flow of arteriovenous fistulain of control group before and after treatment were (859.7±148.3) ml/min and (946.5±169.2) ml/min respectively,and the difference was significant(t=2.356,P<0.05).While blood flow of arteriovenous fistulain,cephalic vein diameter,head of venous flow velocity of study group before and after treatment were (824.6±171.5) ml/min and (1 218.1±241.9) ml/min,(5.59±0.74) mm and (6.02±0.57) mm,(94.23±27.35) cm/s and (115.85±36.63) cm/s,respectively,and the differences were significant(t=8.212,2.382,2.877,P<0.05),there were no significantly changes in the above indexes in the study group after treatment(t=5.3612,2.152,2.281,P<0.05).Conclusion MPC plus MNADDT can reduce the vascular complications of arteriovenous fistula,improve blood vessel diameter and increase blood flow.
2.Determination of limonene in Er Chen Pill by GC
Beili HU ; Yi ZHANG ; Qinyun LI ; Lei ZHANG
Chinese Traditional Patent Medicine 1992;0(06):-
AIM: To control the quality of Er Chen Pill (Pericarpium Citri Reticulatae, Rhizoma Pinellae, Poria, Radix Glycyrrhizae) by determination of limonene by GC. METHODS: HP 6890 GC instrument was employed to determine the content of limonene with column (HP-1 Methyl Siloxane 30m?320?m?0.25?m), detector temperature (250?C), injection temperature (250?C), split ratio (100∶1) and injection amount (1?L). RESULTS: The calibration equation was Y=0.9873X+0.0794(r=0.9995) in the range of 0.45?g~ 1.80?g. The average recovery was 99.6%(RSD=6.9%) and the average content of limonene in the sample was 78.4mg?g -1(RSD=3.2%). Conclusion: The method is simple, quick, and sensitive.
3.Acute myeloid leukemia with BCR-ABL p210 fusion gene-positive: report of one case and review of literature
Ju HUANG ; Yanxia HAN ; Fangxian WEI ; Shanhua SHEN ; Beili HU ; Lihua CHEN ; Zhouzheng WANG
Journal of Leukemia & Lymphoma 2020;29(3):175-178
Objective:To investigate the clinical characteristics of acute myeloid leukemia with BCR-ABL p210 fusion gene-positive.Methods:The clinical characteristics of a patient diagnosed in the Second Hospital of Jiaxing were analyzed and the related literature was reviewed.Results:BCR-ABL p210 fusion gene and Philadelphia chromosome (Ph) were detected by reverse transcription-polymerase chain reaction (RT-PCR) and fluorescence in situ hybridization (FISH). Imatinib associated with multi-drug intravenous chemotherapy resulted in poor efficacy.Conclusions:Patient with Ph +/BCR-ABL + acute myeloid leukemia is rare with a very poor prognosis. There is no unified standard treatment and the efficacy of tyrosine kinase inhibitors is unclear. Intravenous chemotherapy combined with hematopoietic stem cell transplantation is expected to change the prognosis.
4.Performance and clinical evaluation of two serum free light chain detection platforms in the diagnosis of multiple myeloma
Wen XU ; Yuyi HU ; Wenqi SHAO ; Jing ZHU ; Baishen PAN ; Beili WANG ; Wei GUO
Chinese Journal of Laboratory Medicine 2023;46(10):1026-1034
Objective:To compare the detection performance of serum free light chain (sFLC) in two platforms and evaluate the comparability of serum free light chain results in patients with multiple myeloma (MM).Methods:To evaluate the detection performance (repeatability, accuracy, linear range, reference range, interfering substances, etc.) of sFLC kit based on polyclonal antibodies. Spearman correlation analysis and Bland-Altman were used to analyze 214 sFLC results obtained on two detection platforms at the same time to evaluate the correlation between the results of the two methods and analyze the causes of methodological bias. 119 cases with aMM and 23 cases of disease control group (AL, WM, POEMS syndrome, MGUS, diffuse large B-cell lymphoma) initially diagnosed in the hematology department of Zhongshan Hospital of Fudan University from March 2020 to March 2021 were all included. A retrospective analysis was conducted to calculate the area under the curve of receiver operating characteristic (AUC-ROC) and obtain the optimal sensitivity and specificity cut-off points for the diagnosis of MM patients on monoclonal antibody platform.Results:Repeatability, accuracy, linear range, reference interval and anti-interfering capacity of the detection platform based on polyclonal antibodies were verified to meet clinical needs. The overall consistency of FLC/κ, FLC/λ and κ/λ ratios in two methods was 89.3%, 84.1% and 77.1% respectively; but the correlation results were highly heterogeneous. The correlation coefficient of FLC/κ R 2 was 0.922( P<0.001), while the correlation coefficients R 2of the FLC/λ and κ/λ ratios were only 0.349 and 0.441( P<0.001). After segment analysis, it was found that the correlation of FLC/λ was improved within the linear range and R 2 could rise to 0.78( P<0.001). Compared with monoclonal antibody platform, the vast majority points of FLC/κ fell within the 95% limit by Bland Altman analysis. While the results of FLC/λ on polyclonal antibody platform showed significant positive bias. The AUC of MM diagnosis on monoclonal antibody platform was 0.751 ( P=0.001), and the optimal cutoff value was 24.67. Conclusion:The overall consistency between the two platforms was good, but there were significant differences between the results, so they were not comparable and could not be interchanged. For monitoring the prognosis of patients with multiple myeloma, the same platform should be selected for testing.