1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Clinical characteristics and influencing factors of vestibular migraine patients with sleep disorders.
Qingchun PAN ; Bei LI ; Jing ZHANG ; Yuanling WANG ; Xiaoming TANG
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(9):817-823
Objective:To investigate the sleep characteristics and clinical features of patients with vestibular migraine(VM), and to explore the influencing factors of sleep disorder in VM patients. Methods:A cross-sectional study method was adopted to collect VM patients from Otolaryngology department and neurology department of our hospital from June 2022 to June 2024(divided into sleep disorder group and non-sleep disorder group according to whether there is sleep disorder) as the experimental group, and recruit non-VM volunteers with clinical characteristics matching with the experimental group during the same period as the control group. The clinical data of the subjects were collected, and the sleep quality of the subjects was assessed using the Pittsburgh Sleep Quality Index(PSQI). The influencing factors of sleep disorders in VM patients were analyzed by multivariate Logistic regression, and the correlation between sleep disorders and clinical features such as headache, vertigo and hearing in VM patients was analyzed by Spearman correlation coefficient. Results:A total of 530 individuals with VM were analyzed, including 332 with sleep disturbances(62.64%), 198 without sleep issues(37.36%), and 50 in the control group. The overall PSQI score and all its components were significantly higher in the VM group compared with the control group(P<0.05). A positive correlation was observed between PSQI and VAS, DHI-T, DHI-E, DHI-F and DHI-P(r=0.797, P<0.05; r=0.834, P<0.05; r=0.794, P<0.05; r=0.771, P<0.05; r=0.877, P<0.05), PSQI had no correlation with pure tone hearing(r=0.324, P=0.167). Multivariate logistic regression analysis showed that female, age ≥60 years, living alone, duration of disease ≥3 months, motion sickness history, and HADS-A were independent influencing factors for comorbidification of sleep disorder in VM patients(P<0.05). Conclusion:The prevalence of sleep disorders in patients with vestibular migraine(VM) was significantly higher compared to the control group. Moreover, the severity of sleep disorders was positively correlated with the intensity of headache and vertigo in VM patients. It is recommended that female VM patients aged 60 years or older, living alone, with a disease duration of three months or longer, a history of motion sickness, and anxiety symptoms undergo sleep assessments to determine the presence of sleep disorders. This approach provides a theoretical foundation for precise treatment and prevention strategies for VM.
Humans
;
Migraine Disorders/complications*
;
Sleep Wake Disorders/complications*
;
Cross-Sectional Studies
;
Vertigo
;
Female
;
Male
;
Vestibular Diseases/complications*
;
Sleep Quality
;
Adult
;
Middle Aged
;
Logistic Models
7.Histaminergic Innervation of the Ventral Anterior Thalamic Nucleus Alleviates Motor Deficits in a 6-OHDA-Induced Rat Model of Parkinson's Disease.
Han-Ting XU ; Xiao-Ya XI ; Shuang ZHOU ; Yun-Yong XIE ; Zhi-San CUI ; Bei-Bei ZHANG ; Shu-Tao XIE ; Hong-Zhao LI ; Qi-Peng ZHANG ; Yang PAN ; Xiao-Yang ZHANG ; Jing-Ning ZHU
Neuroscience Bulletin 2025;41(4):551-568
The ventral anterior (VA) nucleus of the thalamus is a major target of the basal ganglia and is closely associated with the pathogenesis of Parkinson's disease (PD). Notably, the VA receives direct innervation from the hypothalamic histaminergic system. However, its role in PD remains unknown. Here, we assessed the contribution of histamine to VA neuronal activity and PD motor deficits. Functional magnetic resonance imaging showed reduced VA activity in PD patients. Optogenetic activation of VA neurons or histaminergic afferents significantly alleviated motor deficits in 6-OHDA-induced PD rats. Furthermore, histamine excited VA neurons via H1 and H2 receptors and their coupled hyperpolarization-activated cyclic nucleotide-gated channels, inward-rectifier K+ channels, or Ca2+-activated K+ channels. These results demonstrate that histaminergic afferents actively compensate for Parkinsonian motor deficits by biasing VA activity. These findings suggest that targeting VA histamine receptors and downstream ion channels may be a potential therapeutic strategy for PD motor dysfunction.
Animals
;
Histamine/metabolism*
;
Male
;
Oxidopamine/toxicity*
;
Rats
;
Ventral Thalamic Nuclei/physiopathology*
;
Rats, Sprague-Dawley
;
Disease Models, Animal
;
Parkinson Disease/metabolism*
;
Neurons/physiology*
;
Humans
;
Optogenetics
8.Supramolecular prodrug inspiried by the Rhizoma Coptidis - Fructus Mume herbal pair alleviated inflammatory diseases by inhibiting pyroptosis.
Wenhui QIAN ; Bei ZHANG ; Ming GAO ; Yuting WANG ; Jiachen SHEN ; Dongbing LIANG ; Chao WANG ; Wei WEI ; Xing PAN ; Qiuying YAN ; Dongdong SUN ; Dong ZHU ; Haibo CHENG
Journal of Pharmaceutical Analysis 2025;15(2):101056-101056
Sustained inflammatory responses are closely related to various severe diseases, and inhibiting the excessive activation of inflammasomes and pyroptosis has significant implications for clinical treatment. Natural products have garnered considerable concern for the treatment of inflammation. Huanglian-Wumei decoction (HLWMD) is a classic prescription used for treating inflammatory diseases, but the necessity of their combination and the exact underlying anti-inflammatory mechanism have not yet been elucidated. Inspired by the supramolecular self-assembly strategy and natural drug compatibility theory, we successfully obtained berberine (BBR)-chlorogenic acid (CGA) supramolecular (BCS), which is an herbal pair from HLWMD. Using a series of characterization methods, we confirmed the self-assembly mechanism of BCS. BBR and CGA were self-assembled and stacked into amphiphilic spherical supramolecules in a 2:1 molar ratio, driven by electrostatic interactions, hydrophobic interactions, and π-π stacking; the hydrophilic fragments of CGA were outside, and the hydrophobic fragments of BBR were inside. This stacking pattern significantly improved the anti-inflammatory performance of BCS compared with that of single free molecules. Compared with free molecules, BCS significantly attenuated the release of multiple inflammatory mediators and lipopolysaccharide (LPS)-induced pyroptosis. Its anti-inflammatory mechanism is closely related to the inhibition of intracellular nuclear factor-kappaB (NF-κB) p65 phosphorylation and the noncanonical pyroptosis signalling pathway mediated by caspase-11.
9.The application of ultrasound evaluation of atelectasis in general anesthesia
Liming DAI ; Xiangwei LING ; Wei LI ; Ji ZHU ; Bei PAN ; Fumei TIAN
Journal of Chinese Physician 2024;26(4):564-567
Objective:To explore the application effect of ultrasound evaluation of atelectasis in general anesthesia.Methods:Eighty patients who underwent general anesthesia surgery at the Second Affiliated Hospital of Wannan Medical College from January 2019 to December 2020 were selected as the study subjects. The gold standard was chest CT diagnosis of perioperative atelectasis, and they were divided into atelectasis group (39 cases) and control group (41 cases). Twelve regional images, including left upper anterior chest, left lower anterior chest, right upper anterior chest, right lower anterior chest, left upper chest, left lower chest, right upper chest, right upper chest, right lower chest, right upper chest, right lower chest, right upper chest, right lower chest, right lower chest, right lower chest, left upper chest, right lower chest, left upper chest, right lower chest, left upper posterior region, left lower chest, left lower posterior region, left lower posterior region, right upper posterior region, and right lower posterior region, were collected by pulmonary ultrasound (LUS) at time points T 1 after entering the room, 30 minutes after tracheal intubation (T 2), 30 minutes after extubation (T 3), 24 hours after surgery (T 4), and 48 hours after surgery (T 5), And an improved semi quantitative scoring method for evaluating lung ventilation was used to compare the LUS scores of the two groups at 5 time points. Results:There was no statistically significant difference in LUS scores between the two groups of patients in different lung zones at T 1 (all P>0.05); There are varying degrees of differences in LUS scores for the same lung partition at different times (all P<0.05). There was no statistically significant difference in LUS scores between T 2 and T 5 for left upper anterior chest, left lower anterior chest, right upper anterior chest, left upper chest, right upper chest, left upper posterior region, and right upper posterior region (all P>0.05); The LUS scores of the T 2-T 5 atelectasis group in the lower left chest, lower right chest, lower left posterior area, and lower right posterior area were higher than those of the control group (all P<0.05). Conclusions:LUS can be used to evaluate atelectasis during general anesthesia and has broad clinical application and promotion value.
10.Echocardiography for evaluating diameter and collapsibility index of inferior vena cava in patients with right heart dysfunction
Chunming SHI ; Bowen ZHAO ; Mei PAN ; Xiaohui PENG ; Bei WANG ; Xianchen WANG ; Lijun SHEN
Chinese Journal of Medical Imaging Technology 2024;40(7):1015-1019
Objective To observe the inter-observer consistency of diameter of inferior vena cava(IVC)and IVC collapsibility index(IVCCI)measured and assessed with echocardiography and the correlations with right heart parameters in patients with right heart dysfunction.Methods Forty-seven patients with right heart dysfunction were prospectively recruited in observation group,while 50 adults with normal right heart function were taken as controls(control group).Parameters of the right heart were obtained with echocardiography,including the right ventricular fractional area change(FAC),the tricuspid annular plane systolic excursion(TAPSE),the myocardial performance index(MPI),the tricuspid annular systolic velocity(S')as well as early and late diastolic velocity(e',a')and e'/a' ratio,also the tricuspid valve orifice early and late diastolic velocities(E,A)and E/A ratio and E/e',the vena contracta width of tricuspid regurgitation(TR-VCW),the maximum velocity of tricuspid regurgitation(TR-Vmax),the pulmonary artery systolic pressure(PASP)and right atrial area(RAA).Besides,the maximal and minimal diameter of IVC(IVCDmax,IVCDmin)during the respiratory cycle were measured with two dimensional(2D)ultrasound and anatomical M-mode ultrasound,respectively,and the IVCCI were calculated.Then 20 subjects were randomly selected from each group,and IVC parameters were obtained.The basic data,right heart parameters and IVC parameters were compared between groups,intra-class correlation coefficient(ICC)between 2 sonographers of IVC parameters were calculated,and correlations between IVC parameters and right heart parameters were assessed.Results No significant differences of gender,age nor body mass index(BMI)was detected between groups(all P>0.05).Compared with those in control group,MPI,e',e'/a',E,A,E/e',TR-VCW,TR-Vmax,PASP and RAA increased,whereas FAC,TAPSE,S'and a'decreased in observation group(all P<0.05).The inter-observer consistencies were good for IVCDmax and IVCCI in observation group(ICC=0.787-0.971)and IVCDmax in the control group(ICC=0.971,0.964)obtained with 2D ultrasound and anatomical M-mode ultrasound,but poor for IVCCI in control group(ICC=0.169,0.456).Compared with those in control group,IVC parameters 2D-IVCDmax,2D-IVCDmin,M-IVCDmax and M-IVCDmin increased but 2D-IVCCI and M-IVCCI decreased in observation group(all P<0.05).In control group,2D-IVCDmax was weakly negatively correlated with TAPSE and a'(r=-0.392,-0.364),weakly positively correlated with e'/a',E,E/A,TR-VCW and RAA(r=0.396,0.483,0.461,0.565,0.582),2D-IVCCI was weakly negatively correlated with TR-VCW and RAA(r=-0.386,-0.380),while M-IVCDmax was weakly negatively correlated with TAPSE(r=-0.384),and weakly positively correlated with e'/a',E,E/A,TR-VCW and RAA(r=0.357,0.453,0.473,0.549,0.550),M-IVCCI was weakly negatively correlated with MPI,E,TR-VCW and RAA(r=-0.347,-0.337,-0.475,-0.421).Conclusion In patients with right heart dysfunction,IVCD diameter and IVCCI obtained with echocardiography had good inter-observer consistencies.Parameters obtained with 2D ultrasound and anatomic M-mode ultrasound had certain relations with the right heart parameters.

Result Analysis
Print
Save
E-mail