1.Closure position determination and occluder selection as well as the clinical effect of transcatheter closure on aneurysm-like ventricular septal defects
Qilian XIE ; Zengren ZHAO ; Jun WANG ; Lei GAO ; Baoyong YAN ; Zhen WANG ; Milin ZHANG ; Jin ZHOU ; Wenfeng FAN ; Kunshen LIU
Chinese Journal of Tissue Engineering Research 2008;12(13):2591-2595
BACKGROUND: It is difficult to cover aneurysm-like ventricular septal defect (VSD) of large inlet and multiple outlets completely with symmetrical type occluders or eccentric type occluders. OBJECTIVE: To investigate the feasibility of A4B2 occluder devices for covering aneurysm-like VSD, and to observe the effects of proper occhiders selected according to pseudoaneurysm size on coveting aneurysm-like VSD. DESIGN: Case analysis.SETTING: the First Hospital of Hebei Medical University. PARTICIPANTS: From August 2004 to May 2006, 226 patients with the pseudoaneurysm of petimembranous VSD, who underwent interventional therapy in the First Hospital of Hehei Medical University, were recruited in the study. According to the results of the left ventricular angiography, 36 patients of pseudoaneurysm of petimembranous VSD with large inlet and multiple outlets were closured with A4B2 occluder devices. According to the results of the left ventricular angiography, the mean diameter of the left inlet of VSD was (10.6+8.7) mm (ranged from 8 to 21 mm), the mean diameter of the right outlet of VSD was (3.1 ± 2.9) mm (ranged from 2 to 8 ram). Main materials: Occluder device and delivery mechanism were offered by Shanghai Shape Memory Alloy Materials Company and Beijing Starway Medical Technology Inc. They were processed into double disks using nickel-titanium shape memory alloy wires by a special technology to close VSD by a transcatheter approach. The size of the occluder was denoted with the diameter of the waist, and the Size ranged from 4 to 16 mm in the present study. METHODS: All the occluders were transferred by a 7-10 F transferring sheath from right heart system, and the mean diameter of the occluders was (6.364-2.48) nun (ranged from 4 to 16 ram). Fifteen minutes after the procedure, left ventricular angiography and transthoracic echocardiography (TIE) were performed again to evaluate the efficacy. After the procedure, electrocardiogram (ECG) monitoring lasted for 5 successive days in all patients, and ECG and TIE were performed 1, 3, 6 and 12 months later. MAIN OUTCOME MEASURES: Residual shunt, arrhythmia and valve function as well as blood compatibility. RESULTS: Sixteen cases were closured by placing the occhiders into left inlet of VSD, 16 cases were closured by placing the occluders into the pseudoaneurysm completely, and 4 cases were closured at the outlet of the defects. The results of the left ventricular angiography and TTE that performed fifteen minutes after the procedure demonstrated that 32 cases were completely closured and slightly residual shunts (< 3 mm) was found in other 4 patients. And confirmed by TIE, the residual shunts completely disappeared in 2 of the 3 patients 24 hours later while in the other one in 1 month after the procedure. Temporary left bundle branch block was found in 3 cases while temporary right bundle branch block was found in 2 cases, and all of them recovered within one week. Without severe complications, all of the 36 patients were treated successfully with A4B2 (thin waist shape) occluder devices made in China. Critical appraisal in blood compatibility of the implantation materials used in this research had been performed. The hemolysis ratio was less than 5%, the platelet adhesion was less, and the blood coagulation function ,the immune system response( immunoglobulin and complement)and the re-endothelialization of material surface were all normal. CONCLUSION: Transcatheter interventional therapy with domestic A4B2 occluder devices for VSD with pseudoaneurysm is safe, effective, promising, and has fewer complications. The key to the procedure is to select suitable occluders and suitable positions where to plant them according to the size, morphologic characteristics, position, and maturity of the pseudoaneurysm.
2.Comparison of mid-term clinical outcomes between traumatic stiff shoulder and frozen shoulder after arthroscopic capsule release combined with subacromial space recovery
Lin MA ; Baoyong JIN ; Xiaolong ZHENG ; Aining YANG ; Binghua ZHOU ; Kanglai TANG
Chinese Journal of Orthopaedic Trauma 2021;23(11):924-930
Objective:To compare the mid-term clinical outcomes between traumatic stiff shoulder and frozen shoulder after arthroscopic capsule release combined with subacromial space recovery.Methods:From January 2014 to December 2019, 55 patients were treated at Sports Medicine Center, The First Affiliated Hospital, Army Medical University for limited range of shoulder motion. Of them, 22 suffered from traumatic stiff shoulder (7 males and 15 females) (group A) and 33 from frozen shoulder (10 males and 23 females) (group B). All patients were treated with arthroscopic 270° capsule release combined with subacromial space recovery. Shoulder pain was evaluated by visual analogue scale (VAS) and shoulder function by Constant score before operation and at the final follow-up. The 2 groups were compared in improvements in flexion, abduction, external rotation and internal rotation of the shoulder.Results:No significant difference was observed between the 2 groups in gender, age, course of disease, preoperative internal rotation or external rotation of the shoulder ( P>0.05). Preoperative VAS score [2.5(2.0, 3.3) points] and Constant score [(33.7±9.6) points] in group A were significantly lower than those in group B [4.0(3.0,5.5) points and (45.8±12.3) points] ( P<0.05). No complication like infection or nerve injury was found during follow-ups. All the incisions healed at the first stage. The follow-up time averaged 37.0 months (from 20 to 79 months). At the last follow-up, VAS scores [1.0(1.0, 1.0) points and 1.0(1.0, 1.0) points] and Constant scores [(87.0±3.2) points and (85.7±4.3) points] for both groups were significantly improved compared with their preoperative values [2.5(2.0,3.3)分points and 4.0(3.0,5.5) points for VAS; (33.7±9.6) points and (45.8±12.3) points for Constant score] ( P<0.05). Compared with preoperation, the improvements at the last follow-up were 99.3°±19.9° and 83.3°±27.7° in shoulder anteflexion and 102.0°±21.5° and 83.9°±32.8° in abduction for groups A and B, with greater improvements in group A; the improvements in VAS score for groups A and B were 1.0(1.0, 2.3) points and 3.0(2.0, 4.5) points, with greater improvements in group B; the improvements in Constant score were (53.3±9.5) points and (39.8±12.9) points for groups A and B, with greater improvements in group A. The above comparisons all showed a significant difference between the 2 groups ( P<0.05). Conclusions:Arthroscopic 270° capsule release combined with subacromial space recovery can lead to good mid-term clinical outcomes similar for both traumatic stiff shoulder and frozen shoulder. However, the improvements in flexion, abduction and Constant score may be greater for traumatic stiff shoulder than for frozen shoulder.