1.Comparison of shear wave elastography and quasi-static elastography in the evaluation of radiofrequency ablation:ex vivo experiment
Baoxian LIU ; Guangliang HUANG ; Wenshuo TIAN ; Ming XU ; Manxia LIN ; Xiaohua XIE ; Xiaoyan XIE
Chinese Journal of Ultrasonography 2017;26(4):350-354
Objective To investigate the value of shear wave elastography (SWE) and quasi-static elastography in the evaluation of radiofrequency ablation of pork.Methods Twelve pieces of fresh pork were underwent radiofrequency ablation (RFA) with different target temperatures.Before and after RFA,conventional ultrasound (US),SWE and quasi-static elastography were conducted to visualize the boundaries of RFA zones.The size of ablation zones obtained from conventional ultrasound,SWE and quasi-static elastography measurement were observed and detected the correlativity with pathology findings.Moreover,the Young's modulus and stain ratio of ablated zone were recorded.Results Most ablated boundaries were clearly delineated by both elastography techniques,except one with a low target temperature of 70 ℃.The sizes of ablated zones measured by SWE and quasi-static elastography were closely correlated with pathological findings.However,no ablated zones could be visualized by conventional US.Before and after RFA,the mean,minimum and maximum values of Young's modulus were (24.2 ± 3.8) kPa vs (97.6 ± 29.1) kPa,(9.2 ± 0.7)kPa vs (44.5 ± 7.7)kPa and (29.9 ± 3.8)kPa vs (181.5 ± 36.7)kPa,respectively (all P <0.001).With the increase of target temperature of RFA,the Young's modulus values and the mean strain ratio were significantly increased (all P < 0.01).Conclusions Both SWE and quasi-static elastography are useful tools for evaluating the ablation,which are superior to conventional US.Moreover,SWE can be used to monitor the procedure of ablation.
2.Ultrasound-guided percutaneous ablation treatment for current hepatoblastoma: initial single-center experience
Pengliang LI ; Jia LUO ; Xiaoer ZHANG ; Baoxian LIU ; Luyao ZHOU ; Guangliang HUANG ; Quanyuan SHAN ; Xiaoyan XIE
Journal of Chinese Physician 2017;19(6):813-816
Objective To summarize the first experience with ultrasound-guided percutaneous ab lation treatment (PAT) for recurrent hepatoblastoma (HB) after liver resection in children.Methods From August 2013 to April 2015,PAT was used to treat 6 children with a total of 9 recurrent HB,including 5 patients with 8 tumors in the liver and 1 patient with 1 tumor in the lung.The mean size of ablated tumors was (1.5 ± 0.8) cm,and the tumor size range was 0.7 cm to 3.1 cm.Results Four patients were performed percutaneous radiofrequency ablation (RFA) for recurrent HB;and 2 patients were performed percutaneous ethanol injection (PEI).Ablation success was achieved in all patients (6/6,100%).The complete ablation rate after the first ablation session was 88.9% (8/9) on a tumor-by-tumor basis.Only 1 patient developed a fever with temperature > 39 ℃;it was resolved by conservative therapy.During the follow-up period of 5-30 months,3 patients died to tumor progression.The 1-and 2-year overall survival rates after ablation were 83.3% and 41.7%,respectively.Conclusions PAT is a safe and promising therapy for children with recurrent HB after liver resection,and further investigation in large-scale randomized clinical trials is required to determine its role in the treatment of this disease.
3.Multiple-electrode radiofrequency ablation via switching system in treating early-stage hepatocellular carcinoma
Guangliang HUANG ; Jia LUO ; Xi DING ; Xiaoer ZHANG ; Baoxian LIU ; Manxia LIN ; Ming KUANG ; Xiaoyan XIE
Journal of Chinese Physician 2017;19(6):810-812,816
Objective To retrospectively compare the safety and local efficacy of multiple-electrode switching based radiofrequency ablation (RFA) and the conventional RFA in treating single early-stage hepatocellular carcinoma (HCC).Methods A total of 82 patients with single early-stage HCC received either RFA with a multiple-electrode switching system (n =43) or conventional RFA (n =39) as the first-line treatment.The rate of initial local complete response,major complications and local tumor progression (LTP) were compared between two groups.Results The total ablation time was significantly shorter in the switching-RFA group [(16.7 ± 3.4) mins] than in the conventional RFA group [(29.8 ± 10.4) mins] (P < 0.05).The rate of initial local complete response was 100% (43/43) in the switching-RFA group and 94.9% (37/39) in the conventional RFA group (P >0.05).After a mean follow-up period of (26.4 ± 21.8)months (ranging 3.0-91.6 months),the rates of LTP in the switching-RFA group and conventional RFA group were 16.3% (7/43) and 17.9% (7/39),respectively.The LTP rates in two groups were 16.1% versus 11.2% atyear1,and20.5% versus 20.6% at year2 (P=0.666).Conclusions The multiple-electrode switching based RFA is safe and effective with shorter ablation time in treating single early-stage hepatocellular carcinoma.
4.Analysis of complication associated with Ultrasound-guided percutaneous RFA for hepatic cellular carcinoma
Xiaoer ZHANG ; Guangliang HUANG ; Xiaoyan XIE ; Ming XU ; Baoxian LIU ; Jieyi YE ; Mingde LYU ; Manxia LIN
Journal of Chinese Physician 2017;19(6):804-806
Objective To evaluate the safety and effective of ultrasound-guide percutaneous radio frequency ablation (RFA).Methods Retrospectively analyze the incident,management and influence factors of complication of ultrasound-guide percutaneous RFA.Results From 2001 to 2011,536 patients with 762 lesions underwent RFA were enrolled in this study.Incident of RFA complication was 2.03% (11/536),including 5 (0.92%) major complication.The complication covered fever (1 case),massive hydrothorax (2 cases),hydrothorax accompany with ascites (1 case),massive ascites (1 case),liver abscess (1 case),liver capsule hemorrhage (1 case) and hemothrorax (1 case).No RFA relate mortality was observed.According to logistics regression analysis,the liver function Child-Pugh grading was associated with the RFA complication (P =0.005).Conclusions Ultrasound-guide percutaneous RFA is a safe and effective local treatment approach for hepatocellular carcinoma.It's necessary to comprehensively think over the basic condition of patients and the characters of tumor such as tumor location,size and abutting organs.Nevertheless,an appropriate treatment plan and closely monitor during and after RFA are crucial.
5.Effects of CpG oligonucleotides on the function of peripheral blood mononuclear cells in patients with type 1 diabetes mellitus versus healthy volunteers
Dezeng TIAN ; Mingzhe LIU ; Yongxuan ZHANG ; Xiaohua WEI ; Baoxian REN ; Haimin WANG
Chinese Journal of Tissue Engineering Research 2011;15(1):183-186
BACKGROUND: CpG oligonucleotide has been shown to strengthen the function of peripheral blood mononuclear cells (PBMCs), but its effects on type 1 diabetes mellitus has been rarely reported. OBJECTIVE: To investigate the effects of CpG oligonucleotide on the expression of interferon γ (IFN-γ), interleukin (IL) -12 and IL-10 in PBMCs in patients with type 1 diabetes mellitus versus healthy controls. METHODS: PBMCs were isolated from patients with type 1 diabetes mellitus and healthy controls and then cultured in RPMI-1640 with non-stimulator (control group) and CpG oligonucleotide (CpG oligonucleotide group), respectively. The mRNA expression of IFN-γ, IL-10, and IL-12 in PBMCs was detected by reverse transcription-polymerase chain reaction. RESULTS AND CONCLUSION: mRNA expression of IFN-γ and IL-10 was significantly lower in patients with type 1 diametes mellitus than in healthy controls (P < 0.01). In the CpG oligonucleotide group, the mRNA expression of IFN-γand IL-12 was significantly higher than in the healthy control group (P < 0.01), but the mRNA expression of IL-10 was similar to that in the healthy control group (P > 0.05). These findings demonstrated that CpG oligonucleotide can promote the production of IFN-γ and IL-12 in PBMCs of type 1 diametes mellitus.
6.Influencing factors of quality of shear wave elastography image of focal liver lesions and a reproducibility study
Wenshuo TIAN ; Manxia LIN ; Xiaoyan XIE ; Guangliang HUANG ; Wei WANG ; Baoxian LIU ; Mingde LYU
Chinese Journal of Ultrasonography 2015;(4):307-310
Objective To investigate the influencing factors of quality of shear wave elastography (SWE) image and the reproducibility of using SWE for focal liver lesions .Methods A total number of 289 consecutive patients with 305 lesions (the lesions could be detected on baseline ultrasound with intercostals approach ,and the depth of lesion was less than 10 cm) were undergone SWE examination .The SWE values of both lesion and adjacent liver parenchyma were measured .The quality of images was classified into three grades:“Good” ,“Common” ,and “Poor” .The depth of lesion ,the distance from body surface to liver capsule ,diameter and location of lesion were compared among three groups .Twenty consecutive patients with 20 lesions were performed SWE by two operators and another 20 consecutive patients with 20 lesions were performed SWE by one operator at different time .Intra‐class correlation coefficient was used to evaluate the reproducibility of inter‐ and intra‐ observer .Results A total number of 179 lesions were“Good” ,107“Common” and 19 “Poor” .The distance from body surface to liver capsule was significantly different among three groups [(Good (1 3.4 ± 0 3.5)cm ,Common (1 6.3 ± 0 3.6)cm ,Poor (1 8.7 ± 0 3.9)cm , P < 0 0.01] .No significant difference was found for the depth ,diameter and location of lesions among three groups .For all parameters of SWE both lesion and adjacent parenchyma ,intra‐class correlation coefficient of inter‐and intra‐observer were higher than 0 7.5 .The reproducibility of max SWE value was best of four elasticity parameters for lesion ,which intra‐class correlation coefficient of inter‐and intra‐observer was 0 9.0 and 0 9.6 ,respectively .Conclusions For focal liver lesions which could be detected on baseline ultrasound and the depth of lesions was less than 10 cm ,SWE could be used to evaluate elasticity characteristics with good feasibility and reproducibility .
7.Evaluating laser ablation of rabbit liver tissue in vitro and in vivo
Manxia LIN ; Ming XU ; Guangliang HUANG ; Xiaoyan XIE ; Shuguang ZHENG ; Baoxian LIU ; Mingde LYU
Chinese Journal of Hepatobiliary Surgery 2014;20(3):212-215
Objective To evaluate the ablation zone and temperature changes in the liver caused by laser ablation in vitro and in vivo.Methods Single needle single point laser ablation was performed in vitro with porcine liver using 5 W and 7 W-power and in vivo with rabbit liver using 5 W-power.All energy outputs were 1 800 J.The ablation zone and temperature changes were evaluated.Results Coagulation caused by laser ablation was divided into a black carbonized area and a brown white necrotic area from inside to out,respectively.The mean in vitro ablation range obtained by 5 W and 7 W-power laser ablation was 1.9 cm × 1.2 cm × 1.2 cm and 2.5 cm × 1.5 cm × 1.5 cm,respectively.The mean in vitro black carbonized range obtained by 5 W and 7 W-power laser ablation was 1.1 cm × 0.5 cm × 0.5 cm and 1.4 cm × 0.7 cm ×0.7 cm,respectively.The average maximum temperature using 5 W-power was 243.57 ℃,62.47 ℃ and 34.27 ℃ in the ablation center,5 mm from the center,and 10 mm from the center,respectively.For in vivo liver experimentation,the average maximum temperature using 5 W-power was 62.26 ℃ and 44.35 ℃5 mm and 10 mm from the center,respectively.Conclusion Laser ablation can cause coagulation necrosis of the liver tissue in vitro and in vivo,and the ablation range increased with increasing power.Laser ablation may have potential use in the ablation of tumor localized in critical sites.
8.Different heating modes of Cool-tip on coagulation zone and thremal distribution in vitro and in vivo experiment
Xiaoju LI ; Manxia LIN ; Xiaoyan XIE ; Ming XU ; Bowen ZHUANG ; Ming LIU ; Mingde LYU ; Bei HUANG ; Baoxian LIU ; Xiaoer ZHANG ; Yin LU
Chinese Journal of Ultrasonography 2016;25(6):530-535
Objective To compare the features of different heating modes cauterization mode and standard ablation mode of Cool-tip on coagulation zone and thermal field distribution in order to provide references for focused and accurate vascular occlusion and explore the primary efficacy of Cool-tip applied to intrahepatic vascular occlusion in living dogs Methods Ex-vivo porcine livers were ablated for 2 4 6 8 minites with cauterization mode and standard ablation mode respectively and the long- and short-axis diameters in the greatest dimension were compared The tissue temperature around the tip midpoint and end of the exposed part of radiofrequency electrode were measured under the circumstance of 4 min ablation by the two modes respectively Animal experiment the intrahepatic vessels of 2 Beagles were ablated with cauterization mode one procedure for each animal and contrast-enhanced ultrasound was used to evaluate the perfusion change of liver tissue Gross anatomy and pathological examination of the liver was performed after 1 week Results In the 2 min 4 min 6 min and 8 min ablation the coagulation volume of cauterization mode and standard ablation mode were 1 01 ± 0 41 cm 3 vs 2 95 ± 0 74 cm 3 1 47 ± 0 33 cm 3 vs 5 03±1 06 cm 3 2 29±0 49 cm 3 vs 9 23±2 53 cm 3 2 70±0 24 cm 3 vs 1 5 89±0 77 cm 3 The coagulation volume was significant smaller in cauterization mode than in standard ablation mode P <0 05 for all The peak temperature of cauterization mode presented on the tip of electrode which averaged 94 4℃ in maximum and maintain around 70 ℃ in the equilibrium phase The peak temperature of standard mode presented on the midpoint of the electrode which periodically variated between 70 ℃- 100 ℃ The result of the animal experiment showed that cauterization mode could be used to occlude the intrahepatic vessel in vivo which induced the ischemia and necrosis in the corresponding area Conclusions Cauterization mode and standard alation mode of Cool-tip have different characteristic in terms of coagulation zone and thermal distribution and carterization mode may have a promising application in intrahepatic vascular occlusion.
9.Preliminary application of three-dimensional ultrasound fusion imaging visualization technology guiding precise needle placement for thermal ablation of hepatocellular carcinoma
Yueting SUN ; Yuqing GUO ; Jiaming LIU ; Ming LIU ; Longfei CONG ; Baoxian LIU ; Xiaoyan XIE ; Guangliang HUANG
Chinese Journal of Ultrasonography 2024;33(2):158-164
Objective:To preliminarily explore the clinical value of three-dimensional ultrasound fusion imaging(3DUS FI) visualization technology in guiding precise needle placement during thermal ablation of hepatocellular carcinoma (HCC).Methods:A total of 56 HCC patients (59 lesions)who underwent 3DUS FI guided thermal ablation were retrospectively analyzed in the First Affiliated Hospital of Sun Yat-sen University from November 2019 to December 2021. All patients were collected with three-dimensional ultrasound volume image before ablation which were fused with real-time two-dimensional ultrasound image for registration, and then the tumor and the safety margin of 5 mm were segmented and marked. Finally, the thermal ablation was performed under three-dimensional visualization. Contrast-enhanced CT/MRI was performed 1 month after thermal ablation to evaluate whether the lesion was completely ablated and measure the ablative margin, and the relationship between ablative margin and the incidence of local tumor progression (LTP) was also analyzed.Results:During the ablation, all lesions could be successfully registered and displayed in three-dimension. Postoperative contrast-enhanced ultrasound showed that all lesions were completely ablated. A total of 37 lesions could be evaluated for ablative efficacy and ablative margin based on contrast-enhanced CT/MRI 1 month after themal ablation, of which 32 (86.5%) lesions achieved complete ablation and obtained at least 5 mm ablative margin. During the follow-up period, LTP was occurred in 4 lesions, 3 of the lesions occurred at the ablative margin< 5 mm. Both 1-year and 2-year cumulative LTP rates were all 7.1%. None of patients had serious complications or deaths associated with thermal ablation.Conclusions:3DUS FI real-time guidance technology is feasible and safe in visually guiding precise needle placement during thermal ablation of HCC.
10.Ultrasound-guided percutaneous radiofrequency ablation to treat hepatocellular carcinoma in the caudate lobe
Baoxian LIU ; Ming KUANG ; Yangyang LEI ; Xiao'er ZHANG ; Tongyi HUANG ; Guangliang HUANG ; Chunlin JIANG ; Ming LIU ; Xiaoju LI ; Xiaohua XIE ; Xiaoyan XIE
Chinese Journal of Hepatobiliary Surgery 2018;24(10):654-658
Objective To study the feasibility,efficacy and safety of ultrasound-guided percutaneous radiofrequency ablation (RFA) in the treatment of hepatocellular carcinoma (HCC) in the caudate lobe.Methods From November 2006 to June 2017,31 patients with 31 HCCs located in the caudate lobe were treated with percutaneous RFA at the First Affiliated Hospital of Sun Yat-sen University.The treatment efficacy,complications,and the local tumor progression (LTP),disease-free survival (DFS) and overall survival (OS) rates were analyzed.Results Residual tumors were detected in 5 patients after the first treatment.Complete necrosis was achieved in all the patients after the second treatment.The mean number of ablation sessions was 1.16±0.37.At a follow-up period which ranged from 3 to 65 months,19 patients had died,10 patients were still alive,and 2 patients were lost to follow-up.The 1-,2-,3-,and 5-years OS rates were 78.4%,48.5%,12.1% and 12.1%,respectively.On follow-up,9 caudate lobe HCC lesions were detected to have LTP.The 1-,2-,and 3-years LTP rates were 21.5%,41.6% and 41.6%,respectively;while the 1-,2-,and 3-years DFS rates were 22.3%,11.2% and 11.2%,respectively.Ablationrelated complications were detected in 4 patients.Conclusions Ultrasound-guided percutaneous RFA was safe and effective for patients with HCC in the caudate lobe.These patients should be followed-up closely to detect LTP.