1.A wide-range CRP assay based on label-free immunoassays by bio-layer interferometry
Baoman SU ; Yang LI ; Fen XU ; Qiong YANG ; Tao HUANG ; Yahui LIN ; Zhou ZHOU
Chinese Journal of Laboratory Medicine 2024;47(11):1314-1320
Objective:This study aims to demonstrate the feasibility of using Bio-layer Interferometry (BLI) for label-free detection of peripheral blood biomarkers, using C-reactive protein (CRP) as a model molecule.Methods:A total of 85 clinical remnant serum samples from routine laboratory tests were collected from Fuwai Hospital, Chinese Academy of Medical Sciences, from July 2021 to May 2022. The biotinylated anti-CRP antibody was immobilized onto streptavidin-functionalized BLI probes. The GatorPrime BLI system was used to detect series of diluted CRP standards in real-time, and to generate dynamic binding curves for establishing standard curves based on the relationship between concentration and initial binding rates. The sensitivity of the method, including the limit of blank (LoB), limit of detection (LoD), and limit of quantitation (LoQ), was evaluated according to Clinical & Laboratory Standards Institute (CLSI) guidelines. Serum samples and third-party quality control materials were used to evaluate the precision, while linearity was verified through the dilution of a high-concentration serum series. Method comparison between the label-free BLI assay and conventional clinical laboratory immunoassays was conducted using Passing-Bablok regression and Spearman correlation analysis.Results:The GatorPrime BLI system demonstrated a dynamic detection range of 0.6-300 mg/L for CRP standards, and the linearity within this range was validated using serum samples. The LoB, LoD, and LoQ for this method were determined to be 0.246 mg/L, 0.573 mg/L, and 2.158 mg/L, respectively. Precision analysis showed that the total laboratory imprecision of the four levels of quality control materials (21.15-57.26 mg/L) ranged from 5.8% to 9.0%, and the total imprecision of the two serum samples (2.32 mg/L and 100.06 mg/L) was 22.3% and 7.4%, respectively. Methodological comparison with two commonly used clinical laboratory immunoassays revealed a strong correlation with our method(Passing-Bablok regression: Y=?1.065+1.119 X and Y=?0.452+1.034 X, r=0.993 and r=0.976, P<0.001). Conclusions:The label-free BLI immunoassay method enables the detection of CRP across a broad concentration range in blood samples, with analytical performance meeting the requirements for laboratory testing. This method shows potential as a reliable and efficient alternative for CRP measurement in clinical practice.
2.Astrocytes in Post-traumatic Stress Disorder.
Baoman LI ; Dianjun ZHANG ; Alexei VERKHRATSKY
Neuroscience Bulletin 2022;38(8):953-965
Although posttraumatic stress disorder (PTSD) is on the rise, traumatic events and their consequences are often hidden or minimized by patients for reasons linked to PTSD itself. Traumatic experiences can be broadly classified into mental stress (MS) and traumatic brain injury (TBI), but the cellular mechanisms of MS- or TBI-induced PTSD remain unknown. Recent evidence has shown that the morphological remodeling of astrocytes accompanies and arguably contributes to fearful memories and stress-related disorders. In this review, we summarize the roles of astrocytes in the pathogenesis of MS-PTSD and TBI-PTSD. Astrocytes synthesize and secrete neurotrophic, pro- and anti-inflammatory factors and regulate the microenvironment of the nervous tissue through metabolic pathways, ionostatic control, and homeostatic clearance of neurotransmitters. Stress or trauma-associated impairment of these vital astrocytic functions contribute to the pathophysiological evolution of PTSD and may present therapeutic targets.
Astrocytes
;
Brain Injuries, Traumatic
;
Fear
;
Humans
;
Stress Disorders, Post-Traumatic/therapy*