1.Rhein improves fasting blood glucose, insulin sensitivity of diabetic rats and increases expression levels of PPARγ, GLUT-2 in hepatic tissue
Miaomiao JIN ; Cheng CHI ; Yiming MU ; Baoan WANG ; Xiaoli MA ; Hetang JIA ; Lijuan YANG ; Jingtao DOU ; Juming LU ; Changyu PAN
Chinese Journal of Endocrinology and Metabolism 2008;24(5):537-541
Objective To investigate the effects of rhein on insulin sensitivity of diabetic rats induced by high fat feeding and low dose streptozotocin (STZ), and the possible mechanisms. Methods (1) Fifty-five Wistar rats were randomly divided into normal control group (NC,n=15) and diabetes group (DM, n=40). The NC rats were fed with regular chow and DM rats were fed with high fat diet. Five weeks later, the DM rats were injected with STZ 30 mg/kg once. The 30 diabetic rats were randomly divided into two subgroups, diabetic control group (DM-C) and diabetic group treated with rhein (DM-T). DM-T rats received intragastric administration of rhein and DM-C rats were given equal doses of solvent. All rats were sacrificed eleven weeks later, the blood sample was collected. The body weight, fasting blood glucose (FBG), HbA1C, triglycerides (TG), tolal cholesterol (TC), glycosylated serum protein (GSP) and Fasting insulin (FINS) concentrations were examined.The insulin sensitive index (ISI) and homeostasis model assessment for insulin resistance (HOMA-IR) werecalculated. (2) The PPART and GLUT-2 expression in hepatic tissue were detected by immunohistoehemistry and Western-blot. Results At the end of experiment the FBG [(22.57±3.23 vs 7.11±1.44) mmol/L,P<0.01],HbA1C[(12.49±1.96 vs 8.36±0.84)%, P<0.01], TG [(0.89±0.29 vs 0.58±0.17)nunoL/L,P<0.01],GSP [(57.29±4.14 vs 13.43±2.70)μmoL/L, P<0.01] and tumor necrosis factor-α [TNF-α,(1.365±0.133 vs 1.233±0.159) μg/L, P<0.05] and the liver weight index (0.032±0.004 vs 0.024±0.002, P<0.01) in DM-C rats were higher than those in NC rats. Besides, the ISI of DM-C rats decreased [In(ISI),-5.46±0.61 vs -4.81±0.75, P<0.05] and HOMA-IR elevated [In(HOMA-IR),2.34±0.64 vs 1.70±0.78,P<0.05]. The expression of PPARγ [11 131.7(5 723.1-18 979.4) vs 48 782.1(21 576.7-108 829.5), P<0.01] and GLUT-2 (0.98±0.35 vs 1.29±0.27, P<0.05) of DM-C rats decreased markedly compared with NC rats. Compared with DM-C rats, FBG [(15.94±3.16) mmol/L], HbA1C[(10.51±1.74)%], GSP[(47-31±6.09) μmol/L] in DM-T and the In (HOMA-IR), (1.86±0.30) rats decreased (P<0.05 or P<0.01), and In (ISI), of DM-T rats increased (-4.97±0.29, P<0.05). The expressions of PPARγ [35 156.3(24 554.3-86 660.9)] and GLUT-2 (1.55±0.55) of DM-T rats were up-regulated markedly compared with DM-C rats (P<0.05 or P<0.01). Conclusion Rhein decreased FBG, HbA1C and GSP, and improved the insulin sensitivity in diabetic rats, which might be related to the up-regulated expressions of PPARγ and GLUT-2 in hepatic tissue.
2.Role of Toll-like receptor 7 in the production of inflammatory cytokines in EV-A71-infected human Jurkat T cells.
Jing CHI ; Yaqing HE ; Guangqing YU ; Lei LEI
Chinese Journal of Preventive Medicine 2016;50(3):266-269
OBJECTIVETo investigate the expression of Toll-like receptor (TLR) mRNA in enterovirus 71(EV-A71) infected human Jurkat T cells and clarify the role of TLRs in the pathogenesis of EV-A71 infection-induced inflammation.
METHODSEV-A71 strains were isolated from feces of children patients with hand, foot and mouth disease in 2014 by Shenzhen Center for Disease Control and Prevention. Human Jurkat T cells were infected with 200 μl EV-A71 at 10(3) cell culture infective dose 50%(CCID50)/ml. The expression of TLR1-TLR10 mRNA in human Jurkat T cells was assessed at different exposure time by RT-PCR. Levels of TLR7 mRNA expression were detected by real-time PCR, and levels of myeloid differentiation factor 88 (MyD88) by western blot. The cytokine secretion of interleukin (IL)-6, IL-8 and Tumor Necrosis Factor α (TNF-α) was analyzed by ELISA assay.
RESULTSThe relative expression level of TLR7 mRNA in human Jurkat T cells were 1.26 ± 0.15, 1.75 ± 0.20, 2.26 ± 0.23 and 3.74 ± 0.62 in 6, 12, 24 and 48 h after EV-A71 infection, which the differences were significant with mock-infected group(t values were -2.96, -6.38, -9.57, -7.71; P<0.05). Western blot showed that the protein expression levels of MyD88 had increased 1.34 times and 2.17 times in 24 h and 48 h after EV-A71 infection compared with mock-infected group. After infected for 24 h and 48 h, the levels of IL-6 were (302.86 ± 38.11), (179.70 ± 14.50) pg/ml, which were significantly higher than mock-infected group (176.42 ± 9.60), (179.70 ± 14.50) pg/ml (t values were -5.57, -18.54, P<0.05). The levels of TNF-α in EV-A71 infected group (100.81 ± 9.81) pg/ml was higher than that in mock-infected group (56.19 ± 6.94) pg/ml, and the difference was significant (t=-6.43, P=0.003).
CONCLUSIONTLR7 is the main pattern recognition receptor responsible for EV-A71 recognition in immune cells, which then leads to the activation of TLR7 downstream signaling and the production of proinflammatory cytokines.
Blotting, Western ; Cell Line ; Enterovirus A, Human ; pathogenicity ; Enzyme-Linked Immunosorbent Assay ; Humans ; Interleukin-6 ; metabolism ; Interleukin-8 ; metabolism ; Myeloid Differentiation Factor 88 ; metabolism ; Real-Time Polymerase Chain Reaction ; T-Lymphocytes ; immunology ; virology ; Toll-Like Receptor 7 ; immunology ; Tumor Necrosis Factor-alpha ; metabolism
3.Application and diagnostic value of low dose scan technique of chest CT combined with 3D reconstruction for ribs in chest trauma
Wei PAN ; Xiaodong WEI ; Baoan CHI ; Xutao FANG ; Cui LI
China Medical Equipment 2024;21(1):55-58
Objective:To explore the application and diagnostic value of low-dose scan technique of chest computed tomography(CT)combined with three dimensional(3D)reconstruction for ribs in chest trauma.Methods:A total of 118 patients with highly suspected rib fracture who admitted to the 904th Hospital of People's Liberation Army Joint Service Support Force were selected,and all cases underwent low-dose scan technique of chest CT combined with 3D reconstruction for ribs.The image qualities of chest CT scans with different low-doses combined with 3D reconstruction for ribs were analyzed,and the diagnostic accuracies among low dose scan technique of chest CT,3D reconstruction for ribs and the combination of them for chest trauma were compared.Results:Both the sharpness and clarity of the edges of the bronchi,blood vessels,lung parenchyma,interlobular septum,mediastinum and ribs were poorer,and the artifacts of soft tissue were more and the noise were more when the tube current of CT scan was 50 Ma.Both the sharpness and clarity of the edges of the bronchi,blood vessels,lung parenchyma,interlobular septum,mediastinum and ribs were general,and a part of soft tissues existed artifacts and the noise amounts were less when the tube current of CT scan was 70 Ma,which did not affect the diagnosis.The radiation dose as 50 mA was significantly higher than that as 70 mA,with a statistically significant difference(t=10.969,P<0.05).In 118 patients with chest trauma,the examination of low-dose scan technique of chest CT combined with 3D reconstruction for ribs indicated that there were 112 cases of rib fractures and 7 cases of costal cartilage fractures.In the examined 388 fractures of rib and costal cartilage,355 fractures(91.49%)were rib fractures and 33 fractures(8.51%)were costal cartilage fractures.In 118 patients with chest trauma,76 cases(64.41%)complicated with pulmonary contusions and lacerations,and 41 cases(35.75%)complicated with pleural effusion,and 10 cases(8.47%)complicated with thoracic vertebral fractures,and 6 cases(5.08%)complicated with splenic contusions and lacerations,and 5 cases(4.24%)complicated with mediastinal and subcutaneous emphysemas.The most direct imaging sign of rib fracture was visible and transparent low-density shadow.Chest CT scan can generally better display dislocation of the fractured end.The 3D reconstruction image showed a visibly line-like shadow on one side of rib if only one side of ribs fractured and the other side was intact.A total of 395 rib and costal cartilage fractures were confirmed by 3D reconstruction,which included 363 rib fractures(91.90%)and 32 costal cartilage fractures(8.10%).A total of 410 rib and costal cartilage fractures were confirmed by low-dose scan technique of chest CT combined with 3D reconstruction for ribs,which included 375 rib fractures(91.46%)and 35 costal cartilage fractures(8.54%).In the comparison of 418 rib injuries that were confirmed during surgery,the accuracy of low-dose scan technique of chest CT was 92.82%(388/418)in diagnosing rib and costal cartilage fractures,and the accuracy of 3D reconstruction for ribs was 94.50%(395/418)in diagnosing that,and the accuracy of low-dose scan technique of chest CT combined with 3D reconstruction for ribs was 95.69%(410/418)in diagnosing that.There was a significant difference in accuracy among the three types of examinations(x2=13.062,P<0.05).Conclusion:Low dose scan technique of chest CT combines with 3D reconstruction for ribs can be used in the diagnosis of chest trauma,which has higher accuracy and can provide reliable imaging information for clinical diagnosis and treatment.