1.Interposition of acellular amniotic membrane at the tendon to bone interface would be better for healing than overlaying above the tendon to bone junction in the repair of rotator cuff injury.
Jiang-Tao WANG ; Chun-Bao LI ; Jia-Ting ZHANG ; Ming-Yang AN ; Gang ZHAO ; Yu-Jie LIU
Chinese Journal of Traumatology 2025;28(3):187-192
PURPOSE:
The retear rate of rotator cuff (RC) after surgery is high, and the rapid and functional enthesis regeneration remains a challenge. Whether acellular amniotic membrane (AAM) helps to promote the healing of tendon to bone and which treatment is better are both unclear. The study aims to investigate the effect of AAM on the healing of RC and the best treatment for RC repair.
METHODS:
Thirty-three Sprague Dawley rats underwent RC transection and repair using microsurgical techniques and were randomly divided into the suturing repair only (SRO) group (n = 11), the AAM overlaying (AOL) group (n = 11), and the AAM interposition (AIP) group (n = 11), respectively. Rats were sacrificed at 4 weeks, then examined by subsequent micro-CT, and evaluated by histologic and biomechanical tests. The statistical analyses of one-way ANOVA or Kruskal-Wallis test were performed using with SPSS 23.0. A p < 0.05 was considered a significant difference.
RESULTS:
AAM being intervened between tendon and bone (AIP group) or overlaid over tendon to bone junction (AOL group) in a rat model, promoted enthesis regeneration, increased new bone and cartilage generation, and improved collagen arrangement and biomechanical properties in comparison with suturing repair only (SRO group) (AOL vs. SRO, p < 0.001, p = 0.004, p = 0.003; AIP vs. SRO, p < 0.001, p < 0.001, p < 0.001). Compared with the AOL group, the AIP group had better results in micro-CT evaluation, histological score, and biomechanical testing (p = 0 0.039, p = 0.011, p = 0.003, respectively).
CONCLUSION
In the RC repair model, AAM enhanced regeneration of the tendon to bone junction. This regeneration was more effective when the AAM was intervened at the tendon to bone interface than overlaid above the tendon to bone junction.
Animals
;
Rats, Sprague-Dawley
;
Rotator Cuff Injuries/surgery*
;
Amnion/transplantation*
;
Rats
;
Wound Healing
;
Rotator Cuff/surgery*
;
Male
;
X-Ray Microtomography
;
Tendons/surgery*
;
Biomechanical Phenomena
2.Corrigendum to "Interposition of acellular amniotic membrane at the tendon to bone interface would be better for healing than overlaying above the tendon to bone junction in the repair of rotator cuff injury" Chinese J Traumatol 28 (2025) 187-192.
Jiang-Tao WANG ; Chun-Bao LI ; Jia-Ting ZHANG ; Ming-Yang AN ; Gang ZHAO ; Yu-Jie LIU
Chinese Journal of Traumatology 2025;28(6):518-518
3.Effects of oxymatrine on the proliferation of diffuse large B lymphoma cells by regulating PD-L1
Li-Yun LIU ; Li-Chun ZHENG ; Xiu-Jun LI ; Bao-Li LIU ; Yan ZHANG
The Chinese Journal of Clinical Pharmacology 2024;40(17):2498-2502
Objective To investigate the effects of oxymatrine on proliferation and apoptosis of diffuse large B-cell lymphoma and its molecular mechanism.Methods Human diffuse large B lymphoma cells OCI-LY19 were randomly divided into control group(normal culture),experimental-L group(25.00 μmol·L-1 oxymatrine),experimental-M group(50.00 μmol·L-1 oxymatrine),experimental-H group(100.00 μmol·L-1 oxymatrine),Oxymatrine+si-NC group(transfected with si-NC+100.00 μmol·L-1oxymatrine),Oxymatrine+si-PD-L1 group[transfected with si-programmed death receptor ligand 1(PD-L1)+100.00 μmol·L-1 oxymatrine],Oxymatrine+Vector group(transfected with si-NC+100.00 μmol·L-1 oxymatrine)and oxymatrine+PD-L1 group(transfected with PD-L1+100.00 μmol·L-1 oxymatrine).5-acetylidene-2'-deoxyuridine(EdU)assay was used to detect cell proliferation;Western blot assay was used to detect protein expression;flow cytometry assay was used to detect cell apoptosis.Results The EdU cell proliferation rates in control group,experimental-H group,oxymatrine+si-NC group,oxymatrine+si-PD-L1 group,oxymatrine+Vector group and oxymatrine+PD-L1 group were(33.88±2.79)%,(15.23±1.32)%,(15.84±1.58)%,(10.13±0.90)%,(16.14±1.20)%and(20.84±1.88)%,respectively;the expressions of Cyclin-dependent kinase 4(CDK4)protein were 0.92±0.11,0.37±0.04,0.35±0.04,0.24±0.03,0.38±0.06 and 0.71±0.06,respectively;the apoptosis rates were(3.20±0.07)%,(25.35±2.01)%,(24.81±1.91)%,(30.27±1.65)%,(24.39±2.73)%and(17.97±1.27)%,respectively.The above indicators:Experimental-H group were compared with the control group respectively,and the differences were statistically significant(all P<0.05);there were significant differences between oxymatrine+si-PD-L1 group and oxymatrine+si-NC group(all P<0.05);there were significant differences between oxymatrine+PD-L1 group and oxymatrine+Vector group(all P<0.05).Conclusion Oxymatrine can inhibit the proliferation of OCI-LY19 cells and induce apoptosis by down-regulating the expression of PD-L1.PD-L1 may be a potential target of oxymatrine in the treatment of diffuse large B lymphoma.
4.Proguanil induces bladder cancer cell apoptosis through mediating oxidation-reduction driven ferroptosis
Qing-Hua PAN ; Yin-Long LIU ; Yong LIU ; Bao-Chun LIAO ; Jian HU ; Zhi-Jian ZHU
The Chinese Journal of Clinical Pharmacology 2024;40(20):2988-2992
Objective To explore the potential mechanism of proguanil on the proliferation and apoptosis of bladder cancer cells.Methods 253J cells were randomly divided into control group(normal treatment),proguanil group(42.06 μmol·L-1 proguanil),pcDNA group(transfected with pcDNA+42.06 μmol·L-1 proguanil),FADS2 group[transfected fatty acid desaturase gene 2(FADS2)+42.06 μmol·L-1 proguanil],si-NC(transfection si-NC),si-FADS2(transfection si-FADS2),Ferrostatin-1 group(transfected with si-FADS2+10 μmol·L-1 ferrostatin-1).Real-time fluorescence quantitative polymerase chain reaction(RT-qPCR)assay was used to detect mRNA expression of related genes;Western blot assay was used to detect the expression of each protein;apoptosis was detected by TdT mediated dUDP nick end labeling(Tunel)assay;5-ethynyl-2'-deoxyuridine(EdU)assay to detect cell proliferation;the Transwell assay measures the ability of cells to migrate;Fe2+levels were determined by kit method;DCFH-DA probe was used to detect ROS levels.Results The mRNA levels of FADS2 in control group,proguanil group,pcDNA group and FADS2 group were 1.00±0.11,0.47±0.09,0.49±0.06 and 2.09±0.21,respectively;cell proliferation rate were(100.00±3.50)%,(54.31±4.90)%,(56.46±5.17)%and(78.76±6.50)%,respectively;the apoptosis rate were(3.92±0.53)%,(28.79±3.30)%,(27.20±2.90)%and(7.34±0.68)%,respectively;the migration number were 132.70±9.81,70.10±5.05,68.70±537 and 101.80±11.25,respectively;Fe2+level were(100.00±8.14)%,(201.33±17.84)%,(192.38±21.34)%and(116.70±10.90)%,respectively;GPX4 protein relative expression level were 0.77±0.05,0.31±0.05,0.34±0.05 and 0.68±0.06,respectively.The above indexes in proguanil group were compared with those in control group,the above indexes in FADS2 group were compared with those in pcDNA group,all the differences were statistically significant(all P<0.05).The ROS levels of si-NC,si-FADS2 and Ferrostatin-1 groups were 9.72±1.18,40.94±5.63 and 13.77±1.40,respectively.Compared the si-FADS2 group with the si-NC group,Ferrostatin-1 group compared with si-FADS2 group,ROS level were significantly different(all P<0.05).Conclusion Proguanil can induce the apoptosis of bladder cancer cells by inhibiting FADS2 expression mediated by oxidation-reduction driven ferroptosis pathway.
5.Design of adjustable medical nursing support
Xiao-Chun JIAO ; Qin ZHOU ; Xiao-Qin CAO ; Meng-Dong LIU ; Bao-Li CHEN ; Jiao XUE
Chinese Medical Equipment Journal 2024;45(8):110-112
Objective To design an adjustable and removable nursing support for dressing patients with lower extremity injuries.Methods The adjustable nursing support was composed of a supporting plate,a cylinder,an upper adjustment mechanism and a lower fixation mechanism.The supporting plate was used to hold the leg of the patient,which had a curved st ruc t u re with a length from 40 to 80 cm;the cylinder was internally snap-fitted with a second slip sleeve to facilitate the adjustment of the support plate;the upper adjustment mechanism mainly consisted of a second sliding bar,a second cross bar and an adjustment plate;the lower fixation mechanism was mainly composed of a first clamping plate and a second clamping plate.Results The adjustable nursing support could be firmly fixed on the sickbed,and its height and angle could be adjusted according to the patient's wound position and subjective comfort.Conclusion The adjustable nursing support gains advantages in safety and patient comfort,and can be used for the dressing of patients with lower extremity injuries.[Chinese Medical Equipment Journal,2024,45(8):110-112]
6.Effect of cardiac shock wave therapy on electrocardiogram and myocardial perfusion in coronary artery disease patients
Chun-Mei TIAN ; Jing-Jing ZHENG ; Na JIA ; Lin ZHANG ; Bao-Yi LIU ; Jun-Meng LIU ; Ming LAN ; Bing LIU
Chinese Journal of Interventional Cardiology 2024;32(6):317-323
Objective To explore the effect of cardiac shock wave therapy(CSWT)on ST deviation of electrocardiogram and myocardial perfusion imaging in coronary artery disease(CAD)patients.Methods CAD patients who received CSWT in Cardiology Department of Beijing Hospital from December 2016 to August 2022 were enrolled.Three months of CSWT were conducted with a total of 9 times shock wave treatment.Clinical data,myocardial perfusion imaging data and stress electrocardiogram data were collected.Myocardial perfusion score,electrocardiographic data were compared before and after CSWT.Results A total of 55 patients were finally enrolled.There were 43 male and 12 female patients with an average age of(67.45±8.96)years old.ST deviation on 12 leads of electrocardiogram did not show significant difference before and after CSWT.Myocardial perfusion imaging showed global stress perfusion score(P=0.031)and reverse perfusion score(P=0.024).Global rest ischemia score reduced after CSWT(P=0.034).Target stress perfusion score(P=0.002),target reverse perfusion score(P=0.002),target reverse ischemic area(P=0.001)were improved after CSWT.Conclusions CSWT may not influence ST deviation of electrocardiogram,but may improve myocardial ischemia in CAD patients,
7.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
8.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
9.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
10.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.

Result Analysis
Print
Save
E-mail