3.Correction of posttraumatic deviated nose in 136 cases
Bang-Hua LIU ; Lei WU ; Wei-Jia KONG ; Cheng-Zhang YANG ; Guang-Ping WANG ;
Chinese Journal of Trauma 2003;0(08):-
Objective To explore a good of treating posttraumatic deviated nose. Methods Clinical data of 136 patients with posttraumatic deviated nose were analyzed.Closed nasal bone replacement was employed in 34 patients with the disease history of 20-30 days,while open rhino- plasty approach was employed in 102 patients with the disease history over 6 months to correct their postt- raumatic deviated nose,and straightening the septum and ectomizing the inferior turbinate were done if necessary.Results The follow-up was over one year.In the 34 patients with the disease history of 20- 30 days,the outcome was excellent in 28 cases and good in 6.In the 102 patients with the disease history over 6 months,the outcome was excellent in 81 cases and good in 21.The deformity of nose was corrected satisfactorily.Normal nasal shape and good ventilation were obtained.Conclusion Posttraumatic devi- ated nose deformities are often caused by delayed and inaccurate treatment.Closed nasal bone replace- ment can be employed for the patients with trauma history less than one month,and open rhinoplasty ap- proach and straightening the septum and restoration of the nasal shape are employed for other patients.In this way good results can be obtained.
4.Relationship of urine cobalt and individual exposure levels of cobalt and its compounds in cobalt exposed workers
LUO Xiao ting CHEN Wen DONG Ming WU Chuan LIN Zuo kan TAN Jian ming WU Bang hua
China Occupational Medicine 2022;49(06):615-620
Objective -
To analyze the relationship between cobalt level of post shift urine and individual exposure level of
,
cobalt and its compounds in cobalt exposed workers and to explore the feasibility of using urine cobalt as a biomarker.
Methods -
A total of 148 occupational cobalt exposed workers from a new material company were selected as the exposed
, - -
group and 44 non occupational cobalt exposed workers from the company were selected as the control group using the typical
sampling method. The exposure concentration of time weighted average of cobalt and its compounds in the workplace air of the
-
two groups was determined by inductively coupled plasma mass spectrometry as the individual exposure level. The cobalt levels
- -
of pre shift and post shift urinary samples of the two groups were detected by this method. The linear relationship between the
-
cobalt level of post shift urine and the individual exposure level of cobalt and its compounds in the air of the workplace was
Results - 3
analyzed. The individual exposure level of cobalt and its compounds in the exposed group was 1.10 131.71 μg/m with
(M) 3
the median of 12.23 μg/m. No cobalt and its compounds were detected in the workplace air in the control group. The cobalt
- -
levels of pre shift and post shift urines in exposed group were higher than those in the control group at the same time point
(M: vs , vs , P ) - -
1.54 0.56 μg/L 8.77 0.83 μg/L all <0.01 . The cobalt level of post shift urine was higher than that in pre shift
(M: vs ,P ),
urine in the exposed group 8.77 1.54 μg/L <0.01 and it was positively correlated with the individual exposure level
( ,P ) ,
of cobalt and its compounds Spearman correlation coefficient=0.86 <0.01 . After common logarithm conversion the linear regression equation of the cobalt level of post shift urine and the common logarithm of individual exposure level of cobalt and
(x) :ŷ x( ;F ,
its compounds in the exposed group was as follows = −0.178 + 0.988 coefficient of determination=0.72 =374.75
P ;t , P ) Conclusion -
<0.01 = - 19.36 <0.01 . There was a linear correlation between cobalt level of post shift urine and
occupational cobalt exposure level of cobalt exposed workers. Urinary cobalt can be used as a biomarker of occupational cobalt
5.Determination of dimethyl sulfate in workplace air by pre-column derivatization-high performance liquid chromatography
YUAN Jing RONG Wei feng HU Jia wen HE Jia heng MENG Rui bo WU Chuan WU Bang hua
China Occupational Medicine 2022;52(04):425-
Abstract: Objective - -
To establish a pre column derivatization high performance liquid chromatography method for detecting
Methods
dimethyl sulfate (DMS) in workplace air. DMS in workplace air was collected with mercaptopyridine impregnated
(
silicone tube. The derivative of DMS and mercaptopyridine was eluted by mobile phase phase A: water, phase B: acetonitrile,
∶
the volume ratio was 40 60) , and separated with a C18 column, then detected with diode array detector and quantitated by a
Results -
standard curve. The linear range of DMS was 0.17 40.00 mg/L, with the correlation coefficient of 0.999 95. The
detection limit and the lower limit of quantitation were 0.05 and 0.17 mg/L respectively. The minimum detection concentration
and minimum quantitation concentration were 0.02 and 0.04 mg/m³, respectively (air sample volume of 4.5 L, 1.0 mL sample
- - -
solution). The average desorption efficiency was 98.40% 102.00%. The within run and between run relative standard deviations
- -
were 0.61% 3.92% and 1.71% 6.00%, respectively. The samples could be stored at room temperature for at least 14 days.
Conclusion
This method can be used to detect DMS in workplace air.
6.Research progress on detection methods for nitrobenzene compounds in air
WU Fan YUAN Jing HU Jia wen HE Jia heng MENG Rui bo WU Bang hua RONG Wei feng
China Occupational Medicine 2022;52(04):443-
Abstract:
Nitrobenzene compounds (NBCs) are widely used in the world. It has 40 isomers such as nitrobenzene, dinitrobenzene
and nitrotoluene, that are highly toxic and difficult to degrade and can cause harm to human health in different degrees. At pres⁃
ent, there is no unified standard method and occupational exposure limit for the detection of NBCs in the air. In terms of sampling
medium, solid adsorption tube is mostly used for trapping vapor state NBCs, and filter membrane and solid adsorption tube are
mostly used in series for sampling coexist NBCs in vapor state and aerosol state. In the detection methods, gas chromatography
and liquid chromatography are common, and ultraviolet spectrophotometry, Raman spectroscopy, ion migration spectrometry and
some other rapid response methods and technologies are also used in the detection of NBCs. In the detection of NBCs by gas chro⁃
matography, capillary column separation is commonly used, and the main detectors are flame ionization detector, electron capture
detector and mass spectrometry detector. It is of practical significance to establish a method with high sensitivity, strong practica⁃
bility, convenient operation, and can simultaneously collect and detect a variety of NBCs in different states.
7.Epidemiological investigation on a scrub typhus outbreak in a village from Guangdong province, China.
Jun LIU ; Bang-hua CHEN ; De WU ; Wen-hua LIU ; Li-jun YAO ; Xiao-ting MAO ; Liang-heng XIAO ; Hao-jie ZHONG ; Zhi-qian PENG
Chinese Journal of Epidemiology 2013;34(9):946-947
Aged
;
Animals
;
China
;
epidemiology
;
Disease Outbreaks
;
Female
;
Humans
;
Male
;
Middle Aged
;
Orientia tsutsugamushi
;
Scrub Typhus
;
epidemiology
8.Analysis of sequence and genotype of E gene of the Newly Isolated Japanese encephalitis virus strains in Wuhan, Hubei Province
Ze-Rong ZHU ; Jun-Hua TIAN ; Bang-Hua CHEN ; Jin-Song PENG ; Tai-Ping WU ; Quan HU
Chinese Journal of Experimental and Clinical Virology 2011;25(4):258-261
Objective To analyze the molecular characteristics of the newly isolated two Japanese encephalitis virus strains(JEV) in Wuhan. Methods The mosquitoes were collected in Wuhan from April to October in 2009. The envelope (E) protein gene of JEV was detected using RT-PCR and sequenced.Sequence comparisons and phylogenetic analysis were conducted using DNAstar and MegAlign. Results Two Japanese encephalitis virus (JEV) strains (WHJX09-9, WHJX09-10 ) were isolated from Culex tritaeniorhynchus among 16 mosquito pools and identified as genotype I. The result showed that the homology of the two strains was 98. 9% in nucleotides and 100% in deduced amines. The comparison between the new genotype 1 JEV strains and live attenuated vaccine strain SA14-14-2 in E gene showed that the homology of nucleotide sequence was 87.4% and 87.9% ,the homology of amino acid was 96. 9% (totol 15 amino acid were different) in E gene. The mutation sites of amino acid distributed among three different coding domain,but no antigen binding site and neurotoxin-involved site of amino acid were changed. Conclusion Wuhan had appeared a new genotype of JEV which was different from the former strain isolated in Wuhan,the new JEV strains still had neurotoxicity but had high homology with the vaccine strains adopted in Wuhan. The vaccine could still be adopted to prevent Japanese encephalitis if steps were take to eradicate mosquitos at the same time. laboratory surveillance were also an important task to build an early-warning mechanism against JEV.
9.Chloro-nitrobenzene compounds air sampling tube preparation and determination method
WU fan RONG Wei feng YUAN jing HE Jia heng HU Jia wen MENG Rui bo WU Bang hua YU Ri an
China Occupational Medicine 2022;49(06):697-
Objective - -
To prepare the GDH 5 air sampling tube for simultaneous collection of eight kinds of chloro nitrobenzene
( ) ,
compounds CNBs in the air of workplace and establish a matching determination method using gas chromatography.
Methods - - ,
Eight kinds of CNBs in vapor and aerosol state were collected by self developed GDH 5 air sampling tube desorbed
, , ,
by toluene separated by polysiloxane gas chromatography column detected by microcell electron capture detector and
Results - ( -
quantified by external standard method. It was determined that the air sampling tube was assembled by XAD 2 ion
) - ,
exchange resin and glass fiber filter membrane. The linear range of CNBs was 0.80 240.00 mg/L and the linear correlation
- -
coefficients were greater than 0.999 9. The detection limit was 7.87 13.03 μg/L. The minimum detectable concentration was 0.60
3, - 3( )
1.33 μg/m and the minimum quantitative concentration was 2.00 4.22 μg/m sample 45.00 L . The average desorption
- - (RSD) - , - RSD
efficiency was 101.2% 110.0%. The within run relative standard deviation was 0.8% 4.1% and the between run
- Conclusion -
was 0.3% 5.8%. The samples could be stored for more than 30 days at room temperature. GDH 5 air sampling
tube and its associated determination method can be used for the collection and determination of eight kinds of CNBs in
workplace air.
10.Blood purification, plasma exchange and molecular adsorbents recycling system recur the amanita phalloides mushroom poisoning patients with severe hepatic damage.
Bang-fu WU ; Jiang-ying YANG ; Chao-qiang JIANG ; Rong-hua HUANG ; Wei-wei LIU
Chinese Journal of Hepatology 2003;11(8):507-507
Adolescent
;
Adult
;
Amanita
;
Amanitins
;
blood
;
Child
;
Child, Preschool
;
Female
;
Hemoperfusion
;
Humans
;
Liver Diseases
;
etiology
;
therapy
;
Liver, Artificial
;
Male
;
Mushroom Poisoning
;
complications
;
therapy
;
Plasma Exchange
;
Sorption Detoxification