2.Assessment of thickness of in vivo autograft tendons around the knee and its correlation with anthropometric data, thickness of patella and anterior cruciate ligament tibial foot print diameter
Balgovind S RAJA ; Kshitij GUPTA ; Abdusamad V ; Sukhmin SINGH ; Subhajit MAJI
Anatomy & Cell Biology 2021;54(1):18-24
Inadequate diameters of the autograft tendons are known to be a major cause of graft failure in ligament reconstruction. The purpose of the study was to measure the in-vivo thickness of the available autograft options around the knee and to seek a correlation between the thickness of the tendons and the anthropometric data, patellar thickness and anterior cruciate ligament (ACL) footprint sagittal diameter. Magnetic resonance imaging of 104 consecutive patients with suspected knee injuries were utilized for measurement of the in vivo thickness of pes anserinus tendon (diameter and cross-sectional area [CSA]), patellar tendon (PT) and quadriceps tendon (QT). Pearson’s coefficient was used to find out the relationship between the tendon thickness and anthropometric data, thickness of patella and ACL tibial foot print sagittal diameter. The mean diameters and CSA of the semitendinosus tendon (ST) and gracilis tendon (GT) were 3.77±0.49 mm, 11.62±1.62 mm2 and 2.87±0.27 mm, 6.64±1.18 mm2 respectively. QT and PT thicknesses were 7.36±0.87 mm and 4.50±0.62 mm respectively. Height and the patellar thickness were seen to have moderate correlation with ST and PT thickness. Weak correlation was seen between the other anthropometric variables and tendon thickness. Magnetic resonance imaging (MRI) assessment of tendon sizes is a reliable method with good inter and intra-rater agreement. Assessment of these anatomical structures with help of MRI would be helpful in preoperative planning and can help in identifying those patients at risk of having smaller tendons.
3.Assessment of thickness of in vivo autograft tendons around the knee and its correlation with anthropometric data, thickness of patella and anterior cruciate ligament tibial foot print diameter
Balgovind S RAJA ; Kshitij GUPTA ; Abdusamad V ; Sukhmin SINGH ; Subhajit MAJI
Anatomy & Cell Biology 2021;54(1):18-24
Inadequate diameters of the autograft tendons are known to be a major cause of graft failure in ligament reconstruction. The purpose of the study was to measure the in-vivo thickness of the available autograft options around the knee and to seek a correlation between the thickness of the tendons and the anthropometric data, patellar thickness and anterior cruciate ligament (ACL) footprint sagittal diameter. Magnetic resonance imaging of 104 consecutive patients with suspected knee injuries were utilized for measurement of the in vivo thickness of pes anserinus tendon (diameter and cross-sectional area [CSA]), patellar tendon (PT) and quadriceps tendon (QT). Pearson’s coefficient was used to find out the relationship between the tendon thickness and anthropometric data, thickness of patella and ACL tibial foot print sagittal diameter. The mean diameters and CSA of the semitendinosus tendon (ST) and gracilis tendon (GT) were 3.77±0.49 mm, 11.62±1.62 mm2 and 2.87±0.27 mm, 6.64±1.18 mm2 respectively. QT and PT thicknesses were 7.36±0.87 mm and 4.50±0.62 mm respectively. Height and the patellar thickness were seen to have moderate correlation with ST and PT thickness. Weak correlation was seen between the other anthropometric variables and tendon thickness. Magnetic resonance imaging (MRI) assessment of tendon sizes is a reliable method with good inter and intra-rater agreement. Assessment of these anatomical structures with help of MRI would be helpful in preoperative planning and can help in identifying those patients at risk of having smaller tendons.
4.Role of Additional Coronal Magnetic Resonance Imaging in Decompression and Reconstruction with or without Segment Salvage in Thoracic Spine Tuberculosis
Sudhir SRIVASTAVA ; Nandan MARATHE ; Sunil BHOSALE ; Prajakta BHIDE ; Shaligram PUROHIT ; Chetan SHENDE ; Balgovind RAJA
Asian Spine Journal 2019;13(6):992-1000
STUDY DESIGN: Retrospective and observational study.PURPOSE: The present study aimed to develop guidelines for segment salvage or sacrifice based on the amount and status of the remnant portion of the vertebra as assessed by coronal magnetic resonance imaging (MRI) in addition to sagittal and axial images in thoracic spine tuberculosis (TB).OVERVIEW OF LITERATURE: Indications for surgery have not changed significantly since the ‘middle path regimen’ was proposed by Tuli. Goals of modern surgical management of spinal TB include debridement of diseased vertebrae, spinal cord decompression, deformity correction, and spine stabilization. However, the extent of decompression has not been defined previously. Too less decompression will lead to compromised neurological recovery, whereas large extent of decompression is associated with increased surgical morbidity and longer segment to reconstruct.METHODS: Sixty-five patients with thoracic spine TB were divided into two groups (segment salvage/sacrifice) based on the thickness of the subchondral bone and endplate morphology of the vertebra as seen on MRI. The operative procedure in the form of instrumentation with Hartshill loop rectangle and sublaminar wire using the simultaneous anterior posterior approach in lateral position (versatile approach) was performed. The patients were analyzed for postoperative fusion, improvement in kyphosis angle, and followed up for development of complications.RESULTS: This method of deciding the level of fixation and segment salvage based on coronal MRI in addition to the sagittal and axial images provided good result in 64 of 65 patients, except for one patient in the segment sacrifice group who had graft buckling and resultant kyphosis.CONCLUSIONS: For segment salvage, having a clear three-dimensional idea about the viable remnant bone is important. Viable salvaged segment reduces the morbidity of the procedure, length of the construct, and unnecessary debridement without compromising on the neural recovery and fusion rate. Hence, additional cone down coronal cuts must be required when MRI is suggestive for spinal TB because it will help in the decision making.
Congenital Abnormalities
;
Debridement
;
Decision Making
;
Decompression
;
Humans
;
Kyphosis
;
Magnetic Resonance Imaging
;
Methods
;
Observational Study
;
Retrospective Studies
;
Spinal Cord
;
Spine
;
Surgical Procedures, Operative
;
Transplants
;
Tuberculosis
5.Total Hip Arthroplasty in Protrusio Acetabuli: A Systematic Review
Sajid ANSARI ; Kshitij GUPTA ; Tushar GUPTA ; Balgovind S. RAJA ; Pranav J. ; Roop Bhushan KALIA
Hip & Pelvis 2024;36(1):12-25
Protrusio acetabuli, or abnormal protrusion of the femoral head into the acetabulum, requires performance of a total hip arthroplasty (THA) for which various reconstruction techniques and outcomes have been described. The aim of this systematic review is to provide a comprehensive analysis of the current evidence, evaluate treatment efficacy, compare surgical techniques, and identify topics for future research along with improving evidence-based decision-making, improving patient outcomes in the management of this condition. A thorough systematic review of the PubMed, Embase, Cochrane Library databases, and Scopus library was conducted, and articles describing techniques of THA for treatment of protrusion acetabuli were extracted. The initial search generated 751 results. After exclusion, 18 articles were included. Of these, eight were prospective studies and 10 were retrospective. Surgery was performed on 783 hips with a mean age of 60 years; 80% of females who mostly had inflammatory arthritis were followed up for 8.86 years (range, 2-15.4 years). Good outcomes have been achieved with THA using uncemented cups with bone graft; however, no conclusion could be drawn with regard to the femoral side. It can be concluded that the concept of restoration of the anatomical hip center of rotation is paramount for good outcome and better survival of the implant is important when using uncemented cups with a bone graft. In addition, screw augmentation for fixation is not recommended unless absolutely necessary. The most common complications were aseptic loosening and heterotopic ossification. While the former required revision, conservative management was administered for the latter.