1.Cosmetic medicine of a bio-psycho-social model:theoretical analysis and designs of a clinical work system
Meng YU ; Jianning LI ; Hong TANG ; Wei YU ; Bailin PAN ; Hanbin SONG ; Lan ZHOU
Chinese Journal of Medical Aesthetics and Cosmetology 2011;17(2):132-135
Objective To establish a cosmetic medicine bio-psycho-social model and its theory frame and a new clinical work system. Methods The clinical observation and clustering analysis were used in this study, which based on the modern medicine patterns to carry on the logical proof, theory derivation and systematic design. Results The bio-psycho-social model of cosmetic me dicine with combination of the theory and practice was established, including its concept, theory constitution and clinical work system. Conclusion The bio-psycho-social model of cosmetic medicine can most scientifically and comprehensively explain this discipline rule and clinical work, and it will bring the profound influence on the development of the theory and practice in cosmetic medicine.
2. Case report: sex reassignment surgery for Klinefelter syndrome
Zhaoji XIA ; Pengwu ZHOU ; Bailin PAN
Chinese Journal of Plastic Surgery 2018;34(8):668-670
Klinefelter syndrome is a congenital disease of chromosomal aberrations with a prevalence of 0.8%-2.0% in men, which mainly represented as absence of sexual characteristics such as postpubescent undeveloped or less developed testicular, feminine breast development. This article reports two Klinefelter syndrome patients with chromosome karyotype of 47, XXY from 2006 to 2016. Each has successively received series of sex reassignment surgery to improve their genital and secondary sexual characteristics based on their own preferences, satisfactory outcome is therefore achieved.
3.Comparative study of the findings in thick dense breasts based on two target-filters in digital mammography : a phantom study
Xiao CHEN ; Guoquan CAO ; Xiaomin LIN ; Bailin ZHOU ; Meihao WANG
Chinese Journal of Radiological Medicine and Protection 2018;38(1):64-68
Objective To investigate the radiation dose to phantoms of thick dense breasts (compression thickness > 65 mm) and the influence of Molybdenum-Rhodium (Mo-Rh) and Wolfram Rhodium (W-Rh)) target-filter combination on image quality in full field digital mammography (FFDM).Methods An aluminium plate was placed on polymethyl methacrylate (PMMA) plates to simulate dense breasts.Two of 68 mm in-depth phantoms were used to simulate photography condition of thick dense breasts with 0.1 and 0.2 mm aluminium plates respectively.The two phantoms were exposed automatically,half-automatically and manually.The parameters were recorded for each exposure including the target-filter(T-F),tube voltage (kV),tube current (mAs),average glandular dose (AGD),entrance surface dose (ESD) and the image quality figure inverse (IQFInv).Pearson correlation and regression was used to analyze the influence of AGD on IQFInv.Paired sample t-test was used to analyze the influence of different target-filters on IQFInv and AGD.Results AGD had a positive correlation with IQFInv (r =0.806-0.953,P < 0.05).For the phantom of 0.1 mm aluminium,when the tube current was fixed at 100 mAs or the tube voltage was fixed at 28 kVp,AGD and IQFInv had statistically significant difference for two target-filters(t =3.162-8.028,P <0.05).For the phantom with 0.2 mm aluminium,when the tube current was fixed at 100 mAs under different tube voltage,AGD and IQFInv had statistically significant difference for two target-filters(t =4.768-8.028,P < 0.05);when tube voltage was fixed at 28 kVp under different tube current,AGD had statistically significant difference for two target-filters(t =7.730,P < 0.05),while there was no statistical difference in IQFInv(P > 0.05).In addition,when tube current was 100 mAs,IQFInv had statistically significant difference for two phantoms in W-Rh(t =2.345,P < 0.05).Conclusions W-Rh target-filter combination can achieve lower radiation dose under the guarantee of the image quality compared with Mo-Rh target-filter combination.At the same tube current,W-Rh target-filter combination can provide a better image quality under a relatively high tube voltage.