1.Effects of sacral neuromodulation on urodynamic parameters during the storage phase in patients with neurogenic bladder
Haichao LIU ; Guoqing CHEN ; Peng ZHANG ; Fan ZHANG ; Baihui WANG ; Fei ZHOU ; Yanhe JU
Journal of Modern Urology 2025;30(12):1075-1079
Objective To explore the effects of sacral neuromodulation (SNM) on urodynamic parameters during the storage phase in patients with neurogenic bladder (NB), so as to provide reference for evaluating the efficacy of SNM. Methods A total 49 NB patients undergoing SNM at our hospital during Oct.2012 and May 2025 were enrolled. Baseline data and video-urodynamic parameters were collected. Changes in maximum cystometric capacity, maximum detrusor pressure during storage phase, and bladder compliance before and after treatment were assessed. Improvements in detrusor overactivity (DO) and vesicoureteral reflux (VUR) were also analyzed. Results Among the 49 patients,27 were male and 22 were female, with a mean age of (37.41±15.15) years, a median disease duration of 5.0 (2.0,15.5) years, and a median follow-up of 11 (1,32) months. Up to 37 patients (75.5%) received permanent sacral nerve pulse generator implantation (permanent implant group), while the remaining 12 were classified as the non-permanent implant group. Before and after the test period, all patients showed a significant increase in maximum cystometric capacity [ (218.0 (93.0,358.5) mL vs.300.0 (238.5, 400.0) mL, P<0.001], a decrease in maximum detrusor pressure during the filling phase [32.0 (13.5,71.0) cmH_2 O vs. 20.0 (9.0,50.0) cmH_2 O, P<0.001], and an improvement in bladder compliance [11.8 (8.3,25.6) mL/cmH_2 O vs.26.7 (8.6,44.1) mL/cmH_2O, P<0.001]. In the permanent implant group, comparisons before and after the test period showed an increase in maximum bladder capacity [ (239.16±147.23) mL vs. (312.24±121.83) mL, P<0.001], a decrease in maximum detrusor pressure during filling[32.0 (15.0,58.0) cmH_2 O vs.15.0 (9.0,41.0) cmH_2 O, P<0.05], and improved bladder compliance [10.8 (8.3,23.6) mL/cmH_2 O vs.28.6 (8.6,41.4) mL/cmH_2 O, P<0.001]. No statistically significant differences in these parameters before and after the test period were observed in the non-permanent implant group (P>0.05). A total of 17 patients in the permanent implant group underwent follow-up video urodynamics. Compared to pre-test values, significant improvements were observed in maximum detrusor pressure during filling, and bladder compliance both at the end of the test period and at the last follow-up (P<0.05). However, no statistically significant differences were found in maximum cystometric capacity, maximum detrusor pressure during filling, and bladder compliance between the end of the test period and the last follow-up (P>0.05). Among the 49 patients,21 had DO and 20 had VUR. Both DO and VUR showed improvement after the test period and at the last follow-up. Conclusion SNM can effectively improve storage function in NB patients, ameliorate detrusor overactivity and bladder compliance, and relieve or eliminate VUR in some patients. Long-term follow-up confirms that SNM provides stable therapeutic effects, demonstrating significant clinical value.
2.QL1604 plus paclitaxel-cisplatin/ carboplatin in patients with recurrent or metastatic cervical cancer:an open-label, single-arm, phase II trial
Cheng FANG ; Yun ZHOU ; Yanling FENG ; Liping HE ; Jinjin YU ; Yuzhi LI ; Mei FENG ; Mei PAN ; Lina ZHAO ; Dihong TANG ; Xiumin LI ; Buzhen TAN ; Ruifang AN ; Xiaohui ZHENG ; Meimei SI ; Baihui ZHANG ; Lingyan LI ; Xiaoyan KANG ; Qi ZHOU ; Jihong LIU
Journal of Gynecologic Oncology 2024;35(6):e77-
Objective:
QL1604 is a highly selective, humanized monoclonal antibody against programmed death protein 1. We assessed the efficacy and safety of QL1604 plus chemotherapy as first-line treatment in patients with advanced cervical cancer.
Methods:
This was a multicenter, open-label, single-arm, phase II study. Patients with advanced cervical cancer and not previously treated with systemic chemotherapy were enrolled to receive QL1604 plus paclitaxel and cisplatin/carboplatin on day 1 of each 21-day cycle for up to 6 cycles, followed by QL1604 maintenance treatment.
Results:
Forty-six patients were enrolled and the median follow-up duration was 16.5 months. An 84.8% of patients had recurrent disease and 13.0% had stage IVB disease. The objective response rate (ORR) per Response Evaluation Criteria in Advanced Solid Tumors (RECIST) v1.1 was 58.7% (27/46). The immune ORR per immune RECIST was 60.9% (28/46).The median duration of response was 9.6 months (95% confidence interval [CI]=5.5–not estimable). The median progression-free survival was 8.1 months (95% CI=5.7–14.0). Fortyfive (97.8%) patients experienced treatment-related adverse events (TRAEs). The most common grade≥3 TRAEs (>30%) were neutrophil count decrease (50.0%), anemia (32.6%), and white blood cell count decrease (30.4%).
Conclusion
QL1604 plus paclitaxel-cisplatin/carboplatin showed promising antitumor activity and manageable safety profile as first-line treatment in patients with advanced cervical cancer. Programmed cell death protein 1 inhibitor plus chemotherapy may be a potential treatment option for the patient population who have contraindications or can’t tolerate bevacizumab, which needs to be further verified in phase III confirmatory study.
3.QL1604 plus paclitaxel-cisplatin/ carboplatin in patients with recurrent or metastatic cervical cancer:an open-label, single-arm, phase II trial
Cheng FANG ; Yun ZHOU ; Yanling FENG ; Liping HE ; Jinjin YU ; Yuzhi LI ; Mei FENG ; Mei PAN ; Lina ZHAO ; Dihong TANG ; Xiumin LI ; Buzhen TAN ; Ruifang AN ; Xiaohui ZHENG ; Meimei SI ; Baihui ZHANG ; Lingyan LI ; Xiaoyan KANG ; Qi ZHOU ; Jihong LIU
Journal of Gynecologic Oncology 2024;35(6):e77-
Objective:
QL1604 is a highly selective, humanized monoclonal antibody against programmed death protein 1. We assessed the efficacy and safety of QL1604 plus chemotherapy as first-line treatment in patients with advanced cervical cancer.
Methods:
This was a multicenter, open-label, single-arm, phase II study. Patients with advanced cervical cancer and not previously treated with systemic chemotherapy were enrolled to receive QL1604 plus paclitaxel and cisplatin/carboplatin on day 1 of each 21-day cycle for up to 6 cycles, followed by QL1604 maintenance treatment.
Results:
Forty-six patients were enrolled and the median follow-up duration was 16.5 months. An 84.8% of patients had recurrent disease and 13.0% had stage IVB disease. The objective response rate (ORR) per Response Evaluation Criteria in Advanced Solid Tumors (RECIST) v1.1 was 58.7% (27/46). The immune ORR per immune RECIST was 60.9% (28/46).The median duration of response was 9.6 months (95% confidence interval [CI]=5.5–not estimable). The median progression-free survival was 8.1 months (95% CI=5.7–14.0). Fortyfive (97.8%) patients experienced treatment-related adverse events (TRAEs). The most common grade≥3 TRAEs (>30%) were neutrophil count decrease (50.0%), anemia (32.6%), and white blood cell count decrease (30.4%).
Conclusion
QL1604 plus paclitaxel-cisplatin/carboplatin showed promising antitumor activity and manageable safety profile as first-line treatment in patients with advanced cervical cancer. Programmed cell death protein 1 inhibitor plus chemotherapy may be a potential treatment option for the patient population who have contraindications or can’t tolerate bevacizumab, which needs to be further verified in phase III confirmatory study.
4.Establishment of a rapid detection method for Pseudomonas aeruginosa based on real-time fluorescent recombinase polymerase amplification technology
Yun XING ; Yan ZHANG ; Daohong ZHOU ; Qiu ZHONG ; Yuansu JIANG ; Qing HUANG ; Baihui ZHENG
International Journal of Laboratory Medicine 2024;45(19):2329-2333
Objective To establish a real-time fluorescent recombinase polymerase amplification(RPA)technology for the detection of the virulence gene exoS of Pseudomonas aeruginosa,and evaluate the specifici-ty,sensitivity and practicability of the method.Methods According to the specific conserved region of the vir-ulence gene exoS of Pseudomonas aeruginosa,the specific primers and probes of RPA were designed,and the extracted target DNA was detected to determine the specificity and sensitivity of RPA.Real-time fluorescence quantitative PCR(qPCR)was established to detect the target DNA,and the detection limits of different detec-tion methods for Pseudomonas aeruginosa were compared.The feasibility of RPA in detecting Pseudomonas aeruginosa was further confirmed by the performance verification test of clinical samples.Results The estab-lished RPA detection method had good specificity.Only Pseudomonas aeruginosa had specific amplification curve,but no specific amplification curve for other bacteria.The sensitivity of RPA was 5×102 cfu/mL,which was consistent with the detection limit of qPCR and the results were reliable.The detection time of RPA method was only 30 min,which was significantly lower than that of the traditional method.Conclusion The RPA method for the detection of Pseudomonas aeruginosa established in this study has high specificity and sensitivity,and significantly shortens the detection time compared with the traditional detection method.It can be used for the rapid detection of Pseudomonas aeruginosa in clinical specimens.
5.Retrospective analysis of 350 cases with dissection of lymph nodes posterior to right recurrent laryngeal nerve in endoscopic thyroidectomy through gasless axillary posterior approach
Zhicheng ZHANG ; Tingting LI ; Shitong YU ; Junna GE ; Zhigang WEI ; Baihui SUN ; Weisheng CHEN ; Jie TAN ; Shangtong LEI
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2024;59(1):21-26
Objective:To evaluated the safety and feasibility of dissection of lymph nodes posterior to right recurrent laryngeal nerve (ⅥB compartment) in endoscopic thyroidectomy through gasless axillary posterior approach.Methods:A total of 350 cases with right lobe papillary thyroid carcinoma (PTC) who underwent endoscopic lobectomy, isthmusectomy and central compartment neck dissection via gasless axillary posterior approach based at the Department of General Surgery, Nanfang Hospital, Southern Medical University from June 2020 to December 2022 were retrospectively analyzed. Summarize the clinical, pathological characteristics, and postoperative complications of the patients. SPSS 25.0 was used for statistical analysis of the data.Results:All 350 patients underwent endoscopic surgery successfully, with no conversion to open surgery. There were 303 females and 47 males, with an average age of (36.3±9.2) years. Of those, 287 patients were in pT1a stage, 62 in pT1b stage, and one patient in pT2 stage. There was no T3 or T4 stage patient. The mean numbers of yielded lymph nodes in right central compartment and ⅥB compartment were 8.11±4.65 (range, 1-31) and 2.62±1.86 (range, 1-12), respectively. ⅥB compartment metastasis was detected in 52 (14.86%) of 350 patients. The incidence of transient recurrent laryngeal nerve injury was 0.86%(3/350). Postoperative hematoma occurred in three patients (0.86%).Conclusion:The dissection of ⅥB compartment in endoscopic thyroidectomy through gasless axillary posterior approach is safe and feasible in selected PTC patients
6.Application of three-dimensional printing in cartilage tissue engineering
Shuying YU ; Yu LI ; Xinhao CHENG ; Yijun ZHANG ; Zheng LIU ; Chengxiang YAN ; Baihui XIE ; Ximei WANG
Chinese Journal of Plastic Surgery 2024;40(1):99-106
In the past decades, significant progress has been achived in cartilage regeneration. The traditional techniques for constructing tissue engineering cartilage scaffold mainly include pore agent method (or template method), phase separation method, gas foaming method, freeze-drying method, electrospinning method, etc. Cartilage is heterogeneous, and it is difficult for traditional scaffolds to simulate the high anisotropy of cartilage. Therefore, functional regeneration of cartilage is challenging. With the progress of three-dimensional(3D) printing technology, it is possible to prepare functional bionic scaffolds with fine structure and gradient changes through co-deposition of biomaterials, cells and active biomolecules, so as to achieve functional cartilage regeneration. This article reviewed 3D printing technology of cartilage tissue engineering, and the application of 3D printing technology in cartilage regeneration at different anatomical positions (articular cartilage, auricle cartilage, nasal cartilage). In addition, the importance of preparing bionic constructs with regional structure gradient and regional composition gradient was discussed. 3D bioprinting technology, 4D printing techniques, smart biomaterials brought hope for the construction of bionic tissues and organs.
7.Application of three-dimensional printing in cartilage tissue engineering
Shuying YU ; Yu LI ; Xinhao CHENG ; Yijun ZHANG ; Zheng LIU ; Chengxiang YAN ; Baihui XIE ; Ximei WANG
Chinese Journal of Plastic Surgery 2024;40(1):99-106
In the past decades, significant progress has been achived in cartilage regeneration. The traditional techniques for constructing tissue engineering cartilage scaffold mainly include pore agent method (or template method), phase separation method, gas foaming method, freeze-drying method, electrospinning method, etc. Cartilage is heterogeneous, and it is difficult for traditional scaffolds to simulate the high anisotropy of cartilage. Therefore, functional regeneration of cartilage is challenging. With the progress of three-dimensional(3D) printing technology, it is possible to prepare functional bionic scaffolds with fine structure and gradient changes through co-deposition of biomaterials, cells and active biomolecules, so as to achieve functional cartilage regeneration. This article reviewed 3D printing technology of cartilage tissue engineering, and the application of 3D printing technology in cartilage regeneration at different anatomical positions (articular cartilage, auricle cartilage, nasal cartilage). In addition, the importance of preparing bionic constructs with regional structure gradient and regional composition gradient was discussed. 3D bioprinting technology, 4D printing techniques, smart biomaterials brought hope for the construction of bionic tissues and organs.
8.Relationship between lens parameters and ocular anatomical characteristics in myopia patients
International Eye Science 2024;24(7):1043-1051
AIM:To investigate the relationship among lens parameters and their correlation with ocular anatomic characteristics in myopia patients implanted with posterior-chamber phakic implantable collamer lens(Phakic-ICL).METHODS:Retrospective study. A total of 46 myopia patients(46 eyes)who underwent Phakic-ICL implantation were collected in the Wuxi Huaxia Eye Hospital from June 2022 to June 2023. Preoperative evaluation of ocular anatomical characteristics included corneal central thickness(CCT), anterior chamber depth(ACD), axial length(AL), white-to-white(WTW), horizontal sulcus to sulcus(STSH), horizontal angle to angle(ATAH), and vertical sulcus to sulcus(STSV), vertical angle to angle(ATAV). Furthermore, lens parameters included horizontal crystalline lens rise(CLRH), vertical CLR(CLRV)and vertical lens thickness(LTV). The difference, consistency and correlation of the above parameters were analyzed.RESULTS:Except for differences between WTW and STSV, STSH and ATAV, which were not statistically significant(all P>0.05), the other horizontal and vertical ocular anatomical characteristics were statistically significant(P<0.05). CLRH and CLRV had statistically significant difference(P<0.01), while LTH and LTV were not statistically significant difference(P>0.05). Bland-Altman results revealed that the anatomical characteristics in the horizontal or vertical diameters showed poor consistency. The consistency between CLRH and CLRV was poor. There was consistency between LTH and LTV, with the 95% limits of agreement(LoA)between the differences ranging from -0.21 to 0.28 mm, and the proportion of out-of-line points off the 95% LoA was 4.35%. Pearson correlation analysis revealed that there were correlations between the anatomical characteristics of the horizontal and vertical diameters(P<0.01). Meanwhile, there was no correlation between the anteroposterior diameters(P>0.05). There were correlations between the lens parameters(P<0.05), excepted for the CLRH, LTH and LTV, which had no correlation. AL correlated with the anatomical characteristics of the horizontal and vertical diameters(P<0.05), but it had no correlation with lens parameters(P>0.05). Multiple linear regression analysis revealed that LT=0.419+0.017×age-0.548×ACD+0.371×ATAH+0.884×CLRV, CLRH=-0.443+0.809×CLRV, CLRV=-0.092-0.200×ATAH+0.560×CLRH(corrected R2=0.458, 0.482, 0.589, respectively).CONCLUSION:Horizontal and vertical diameters were not interchangeable. CLRH and CLRV were not interchangeable, while LTH and LTV were interchangeable. Partial lens parameters, WTW, STS, and ATA were correlated with ACD. Finally, age, ACD, ATAH, and CLRV influenced LT.
9.Mechanism of oxidative stress-AMPK-Cx43-NLRP3 pathway regulating extracellular matrix remodeling of rat gastric smooth muscle cells under high glucose condition
Gaoyuan ZHANG ; Baihui SONG ; Yitegele BAO ; Mohan ZHANG
Chinese Journal of Pathophysiology 2024;40(1):68-73
AIM:To investigate the regulatory effect of oxidative stress-AMP-activated protein kinase(AMPK)-connexin 43(Cx43)-nucleotide-binding oligomerization domain-like receptor protein 3(NLRP3)pathway on extracellular matrix(ECM)remodeling of gastric smooth muscle cells under high glucose(HG)condition.METHODS:Primary rat smooth muscle cells cultured in vitro were divided into normal glucose group,HG group,HG+NLRP3 inhibitor MCC950(15 nmol/L)group,HG+Cx43 hemichannel blocker GAP19(100 μmol/L)group,HG+AMPK inhibitor Compound C(CC;10 μmol/L)group,and high glucose+antioxidant α-lipoic acid(α-LA;100 μmol/L)group,which were all cultured for 48 h for detection.The protein levels of caspase-1,matrix metalloproteinase-2(MMP-2),NLRP3,Cx43,transforming growth factor-β1(TGF-β1),TGF-β3,tissue inhibitor of metalloproteinase-1(TIMP-1),purinergic P2X7 receptor(P2X7R)and phosphorylated AMPK(p-AMPK)in the cells were detected by Western blot.The levels of adenosine tri-phosphate,interleukin-1β,collagen type Ⅰ(Col I)and collagen type Ⅲ(Col Ⅲ)in the cell culture medium were deter-mined by ELISA.RESULTS:Compared with HG group,the levels of MMP-2 and TGF-β3 in HG+MCC950 group were decreased(P<0.01),while the levels of TGF-β1 and TIMP-1 were increased(P<0.01).The levels of NLRP3 and cas-pase-1 in HG+GAP19 group were decreased(P<0.01),while the expression of P2X7R was not changed.The levels of NLRP3,caspase-1,P2X7R,total Cx43 and membrane Cx43,and the ratio of membrane Cx43 to cytoplasmic Cx43 were decreased in HG+CC group(P<0.01).The levels of p-AMPK,caspase-1,NLRP3,P2X7R,total Cx43 and membrane Cx43,and the ratio of membrane Cx43 to cytoplasmic Cx43 were decreased in HG+α-LA group(P<0.05).CONCLU-SION:High glucose regulates the content of Col I and Col Ⅲ through the oxidative stress-AMPK-Cx43-NLRP3 pathway,thereby participating in the extracellular matrix remodeling of gastric smooth muscle cells.
10.QL1604 plus paclitaxel-cisplatin/ carboplatin in patients with recurrent or metastatic cervical cancer:an open-label, single-arm, phase II trial
Cheng FANG ; Yun ZHOU ; Yanling FENG ; Liping HE ; Jinjin YU ; Yuzhi LI ; Mei FENG ; Mei PAN ; Lina ZHAO ; Dihong TANG ; Xiumin LI ; Buzhen TAN ; Ruifang AN ; Xiaohui ZHENG ; Meimei SI ; Baihui ZHANG ; Lingyan LI ; Xiaoyan KANG ; Qi ZHOU ; Jihong LIU
Journal of Gynecologic Oncology 2024;35(6):e77-
Objective:
QL1604 is a highly selective, humanized monoclonal antibody against programmed death protein 1. We assessed the efficacy and safety of QL1604 plus chemotherapy as first-line treatment in patients with advanced cervical cancer.
Methods:
This was a multicenter, open-label, single-arm, phase II study. Patients with advanced cervical cancer and not previously treated with systemic chemotherapy were enrolled to receive QL1604 plus paclitaxel and cisplatin/carboplatin on day 1 of each 21-day cycle for up to 6 cycles, followed by QL1604 maintenance treatment.
Results:
Forty-six patients were enrolled and the median follow-up duration was 16.5 months. An 84.8% of patients had recurrent disease and 13.0% had stage IVB disease. The objective response rate (ORR) per Response Evaluation Criteria in Advanced Solid Tumors (RECIST) v1.1 was 58.7% (27/46). The immune ORR per immune RECIST was 60.9% (28/46).The median duration of response was 9.6 months (95% confidence interval [CI]=5.5–not estimable). The median progression-free survival was 8.1 months (95% CI=5.7–14.0). Fortyfive (97.8%) patients experienced treatment-related adverse events (TRAEs). The most common grade≥3 TRAEs (>30%) were neutrophil count decrease (50.0%), anemia (32.6%), and white blood cell count decrease (30.4%).
Conclusion
QL1604 plus paclitaxel-cisplatin/carboplatin showed promising antitumor activity and manageable safety profile as first-line treatment in patients with advanced cervical cancer. Programmed cell death protein 1 inhibitor plus chemotherapy may be a potential treatment option for the patient population who have contraindications or can’t tolerate bevacizumab, which needs to be further verified in phase III confirmatory study.

Result Analysis
Print
Save
E-mail