1.Development of automatic urine monitoring system.
Liang WEI ; Yongqin LI ; Bihua CHEN
Chinese Journal of Medical Instrumentation 2014;38(2):114-121
An automatic urine monitoring system is presented to replace manual operation. The system is composed of the flow sensor, MSP430f149 single chip microcomputer, human-computer interaction module, LCD module, clock module and memory module. The signal of urine volume is captured when the urine flows through the flow sensor and then displayed on the LCD after data processing. The experiment results suggest that the design of the monitor provides a high stability, accurate measurement and good real-time, and meets the demand of the clinical application.
Autoanalysis
;
instrumentation
;
Equipment Design
;
Monitoring, Physiologic
;
instrumentation
;
Urination
2.Modeling and implementation method for the automatic biochemistry analyzer control system.
Dong WANG ; Wan-cheng GE ; Chun-lin SONG ; Yun-guang WANG
Chinese Journal of Medical Instrumentation 2009;33(3):217-220
In this paper the system structure The automatic biochemistry analyzer is a necessary instrument for clinical diagnostics. First of is analyzed. The system problems description and the fundamental principles for dispatch are brought forward. Then this text puts emphasis on the modeling for the automatic biochemistry analyzer control system. The objects model and the communications model are put forward. Finally, the implementation method is designed. It indicates that the system based on the model has good performance.
Autoanalysis
;
instrumentation
;
methods
;
Biochemistry
;
instrumentation
;
methods
;
Equipment Design
;
Models, Theoretical
3.Evaluation of Performance and False Positivity of Mediace RPR Test that Uses a Chemistry Autoanalyzer.
Jaekwang NOH ; Hak Hyun KO ; Yeomin YUN ; Young Sook CHOI ; Sang Gon LEE ; Sue SHIN ; Kyou Sup HAN ; Eun Young SONG
The Korean Journal of Laboratory Medicine 2008;28(4):312-318
BACKGROUND: We evaluated the performance and false positive rate of Mediace RPR test (Sekisui, Japan), a newly introduced nontreponemal test using a chemistry autoanalyzer. METHODS: The sensitivity of Mediace RPR test was analyzed using sera from 50 patients with syphilis in different stages (8 primary, 7 secondary, and 35 latent), 14 sera positive with fluorescent treponemal antibody absorption (FTA-ABS) IgM, and 74 sera positive with conventional rapid plasma regain (RPR) card test (Asan, Korea) and also positive with Treponema pallidum hemagglutination (TPHA) test or FTA-ABS IgG test. The specificity was analyzed on 108 healthy blood donors. We also performed RPR card test on 302 sera that had been tested positive with Mediace RPR test and also performed TPHA or FTA-ABS IgG test to analyze the false positive rate of Mediace RPR test. A cutoff value of 0.5 R.U. (RPR unit) was used for Mediace RPR test. RESULTS: Mediace RPR test on syphilitic sera of different stages (primary, secondary, and latent stages) and FTA-ABS IgM positive sera showed a sensitivity of 100%, 100%, 82.9% and 100%, respectively. Among the 74 sera positive with conventional RPR card test and TPHA or FTA-ABS IgG test, 55 were positive with Mediace test. The specificity of Mediace RPR test on blood donors was 97.2%. Among the 302 sera positive with Mediace RPR test, 137 sera (45.4%) were negative by RPR card and TPHA/FTA-ABS IgG tests. CONCLUSIONS: Although the sensitivities of Mediace RPR were good for primary and secondary syphilis, due to its high negative rate of Mediace RPR over the conventional RPR positive samples, further studies are necessary whether it can replace conventional nontreponemal test for screening purpose. Moreover, in view of the high false positive rate, positive results by Mediace RPR test should be confirmed with treponemal tests.
Autoanalysis/methods
;
False Positive Reactions
;
Humans
;
ROC Curve
;
Sensitivity and Specificity
;
Syphilis/*diagnosis
;
Syphilis Serodiagnosis/*methods
4.Evaluation of iQ200 Automated Urine Microscopy Analyzer.
The Korean Journal of Laboratory Medicine 2008;28(4):267-273
BACKGROUND: Microscopic examination of urine sediment is one of the most commonly performed tests in the clinical laboratory. However, manual microscopic sediment examination is labor-intensive, time-consuming and imprecise. In this study, we evaluated the analytical performance and clinical usefulness of a recently introduced image-based automated urinalysis system, Iris iQ200 (Iris Diagnostics, USA). METHODS: We assessed the iQ200 for linearity, precision and carryover rate using patient's samples and quality control materials. On 337 urine samples, urine sediment analyses performed by the iQ200 were compared with manual microscopy results. RESULTS: The iQ200 showed a good linearity (r2>0.99) for all cellular components analyzed. Within-run and total CVs on urine specimens and quality control samples were less than 10% except for within-run CV for the samples with low concentration of the squamous epithelial cells. The carryover rates were 0.21% for RBCs and 1.92% for WBCs. The agreement rates within one grade between the iQ200 and manual microscopy for RBCs, WBCs, and squamous epithelial cells were 93.8%, 94.2% and 96.9%, respectively. CONCLUSIONS: Since the iQ200 showed a reliable analytical performance and good concordance with manual microscopy, it could be useful in the clinical practice as a screening procedure.
Autoanalysis/methods
;
Humans
;
Quality Control
;
Sensitivity and Specificity
;
Urinalysis/*instrumentation
;
Urine/*cytology/microbiology
5.Assessment of the capability of the fluid model of automatic blood cell analyzer in white blood cell count and classification.
Jun SHEN ; Yin CHEN ; Guo-Zhen WANG ; Liang MA ; Cheng-Wu HAN
Chinese Journal of Hematology 2013;34(7):629-631
OBJECTIVETo evaluate the application of XT-4000i automatic blood cell analyzer in white cell count and classification of cerebrospinal fluid (CSF).
METHODSThe fluid model of XT-4000i automatic blood cell analyzer was directly used to detect the white cell count and classification in 200 samples of CSF, and compared with the results obtained by manually microscopic counting method. White blood cell classification was performed by manual method under microscope with Wright's staining,and instrumental method with fluorescence staining and flow cytometry.
RESULTSThere is no statistical difference between instrumental and manual method in detecting the absolute counting of WBC, RBC, mononuclear cell and multinucleate cells (P>0.05), and there is a good correlation between the two methods (r=0.987, 0.999, 0.981 and 0.983 for WBC, RBC, mononuclear cell and multinucleate cell counts). Tumor cells in the samples with high fluorescent staining by instrumental method can be identified with Wright's staining by microscope method, which were consistent with the clinical diagnosis.
CONCLUSIONThe fluid model of XT-4000i automatic blood cell analyzer was rapid and accurate in CSF white cell count and classification,and it also can provide preliminary information for tumor cells screening. The fluid model of XT-4000i automatic blood cell analyzer in white cell count and classification of CSF has the value of popularization in clinical application.
Autoanalysis ; instrumentation ; methods ; Cerebrospinal Fluid ; cytology ; Humans ; Leukocyte Count ; instrumentation ; methods ; Leukocytes ; classification
6.Influence of serum storage on the laboratory results of prostate-specific antigen.
Guo-Rui LIU ; Bing LUO ; Tian ZHENG ; Xiao-Ling YAN ; Xiao-Jun LI ; Ai-Li WANG
National Journal of Andrology 2013;19(7):637-641
OBJECTIVETo investigate the influence of serum storage on the laboratory results of serum T-PSA, F-PSA and FPSA%.
METHODSUsing automated chemiluminescence, we detected and compared the values of serum T-PSA, F-PSA and F-PSA% in the serum stored in different conditions.
RESULTSWhen the serum was stored at 4 degrees C or at the room temperature (22 - 26 degrees C), FPSA was unstable as compared with T-PSA. Compared with the initial value, after 4 hours at the room temperature, F-PSA was decreased to (0.392 +/- 0.246) microg/L (P < 0.01), while T-PSA and F-PSA% to (1.522 +/- 1.085) microg/L and (25.03 +/- 5.94)%, respectively, with no significant difference; after 8 hours at the room temperature, T-PSA and F-PSA were reduced to (1.513 +/- 1.083) and (0.389 +/- 0.247) microg/L (P < 0.05 and P < 0.01). At 4 degrees C, T-PSA, F-PSA and F-PSA% were decreased to (9.418 +/- 7.965) microg/L, (2.168 +/- 1.558) micro/L and (26.6 +/- 6.63)%, respectively, after 2 days (P < 0.05), and to (9.203 +/- 7.736) microg/L, (2.047 +/- 1.478) microg/L and (25.64 +/- 6.56)% after 1 week (P < 0.01). At -40 degrees C, T-PSA, F-PSA and F-PSA% were (4.532 +/- 4.393) microg/L, (1.178 +/- 1.034) microg/L and (24.45 +/- 8.81)% after 4 weeks. When the serum was stored at -40 degrees C and after 3 freeze-thaws, F-PSA and T-PSA were (5.982 +/- 5.314) and (1.341 +/- 1.029) microg/L, respectively, with no significant difference from the initial values.
CONCLUSIONDifferent conditions of serum storage have different influences on the laboratory results of serum TPSA, F-PSA and F-PSA%, more on F-PSA than on T-PSA, while F-PSA% is relatively stable. At -40 degrees C, T-PSA and F-PSA may remain stable for a month at least. Repeated freeze-thaws of the serum do not affect the laboratory results of F-PSA and T-PSA.
Autoanalysis ; Blood Preservation ; methods ; Humans ; Male ; Prostate-Specific Antigen ; blood ; Serum ; Temperature
7.Evaluation of the Abbott Cell-Dyn Sapphire Hematology Analyzer.
Younhee PARK ; Jaewoo SONG ; Sungwook SONG ; Kyung Soon SONG ; Mee Suk AHN ; Mi Sook YANG ; Il KIM ; Jong Rak CHOI
The Korean Journal of Laboratory Medicine 2007;27(3):162-168
BACKGROUND: The performance of Cell-Dyn Sapphire (Abbott Diagnostic, USA) was compared to the Bayer Advia 2120 (Bayer Diagnostics, USA), Sysmex XE-2100 (Sysmex Corporation, Japan), and reference microscopy. METHODS: Three hundred samples for routine CBC and WBC differentials were randomly chosen for a comparison analysis. The Cell-Dyn Sapphire system was evaluated according to the linearity, imprecision, inter-instrument correlations, and white blood cell differential. RESULTS: The CBC parameters (WBC, RBC, hemoglobin and platelet) showed a significant linearity with correlation coefficients greater than 0.99 (P<0.0001). Coefficients of variation (CV) for withinrun and differential count of WBC were less than 5% except for Total CV for monocytes, eosinophils, and basophils and within-run CV for low valued eosinophils. The correlation coefficients with manual count were lower in monocytes, eosinophils, and basophils than in neutrophils and lymphocytes. The correlation with other hematology anlayzers was significant exclusive of basophils. CONCLUSIONS: These results demonstrate that the Cell-Dyn Sapphire has a good linearity, an acceptable reproducibility, a minimal carryover, and a comparable performance with the sysmex XE-2100 and Advia 2120.
Analysis of Variance
;
Autoanalysis
;
Blood Cell Count/*instrumentation/methods
;
Blood Specimen Collection
;
Diagnostic Errors
;
Humans
;
Reproducibility of Results
;
Sensitivity and Specificity
8.Assessment of the performance of an automated analysis system in detecting C3 and C4.
Lei SUN ; Xian-zhang HUANG ; Jun-hua ZHUANG ; Jian-hua XU ; Lian-ying LIN ; Pei-feng KE
Journal of Southern Medical University 2009;29(5):884-886
OBJECTIVETo evaluate the performance of BNII auto-analyzer system in detecting C3 and C4.
METHODSCLSI protocols (EP15-A, EP6-A, EP9-A2) and other relevant literatures were use to or evaluate the precision, accuracy, linearity of C3 and C4 detection by the auto-analyzer system, and the results were compared with the recognized standards.
RESULTSThe relative bias of C3 and C4 was less than one third of the CLIA'88 standard and the precision met the clinical requirement. The results tested by DADE BNII system were not compatible with those by Roche Modular System. C3 showed good linearity in the tests (R2>0.975, P<0.05) with a linearity range of 0.18-5.1 g/L. The linearity of C4 was not available because of lack of high-level samples.
CONCLUSIONThe performances of DADE BNII System basically meet the recognized standards in clinical detection of C3 and C4, but the method comparison needs further validation.
Autoanalysis ; methods ; Blood Chemical Analysis ; instrumentation ; methods ; Complement C3 ; analysis ; Complement C4 ; analysis ; Humans ; Nephelometry and Turbidimetry ; instrumentation ; methods ; Proteins ; analysis ; Sensitivity and Specificity
9.Application of comparison method in internal quality control of hematology analyzer by using fresh blood.
Wen-jun WANG ; Pei-pei WANG ; Xue-fen LI ; Xia-qin GE ; Ming TONG ; Xi-chao GUO
Journal of Zhejiang University. Medical sciences 2008;37(1):88-92
OBJECTIVETo investigate the comparison method on internal control of hematology analyzer by using fresh blood.
METHODSThe hematology analyzer with well function was selected as the reference analyzer, fresh blood samples from healthy subjects were measured by reference analyzer and the values were used to calibrate compared hematology analyzers. The acceptable limits of relative deviation of WBC,RBC, HGB,HCT, PLT were established by comparative experiments during three months. The results of fresh blood samples from patients with low/medium/high levels measured by compared analyzer were compared with those from reference analyzer, the relative deviation of WBC, RBC, HGB, HCT, PLT was calculated respectively. The internal quality control charts in laboratory information system were established, with date as x-axis, relative deviation as y-axis. The acceptable relative deviation limits were set to be +/-2 s, and to be used for laboratory quality control.
RESULTThe relative deviation of WBC, RBC, HGB, HCT, PLT with high, medium, low levels were(0.75+/-2.964)%, (1.19+/-2.488)%,(1.43+/-2.439)%; (-0.39+/-1.327)%, (-0.26+/-1.297)%, (-0.35+/-1.095)%û(-0.43+/-1.393)%, (-0.17+/-1.139)%, (0.24+/-1.166)%û(-.43+/-1.362)%, (-0.36+/-1.381)%, (-0.57+/-1.299)%û(-0.93+/-4.330)%,(0.04+/-4.118)%, (-0.41+/-4.149)%, respectively in 2006. As the second instrument, the compared analyzer was involved in College of American Pathologists Proficiency Testing with satisfactory results, the bias of WBC,RBC, HGB, HCT, PLT were within (-0.5 approximately 5.1)%, (-1.0 approximately 1.6)%, (-1.7 approximately 1.4)%, (-1.5 approximately 1.3)%, (-4.5 approximately 7.4)%, respectively.
CONCLUSIONThe quality control on compared hematology analyzer can be effectively, conveniently and economically performed using this method.
Autoanalysis ; methods ; Blood ; Erythrocyte Count ; instrumentation ; Hematology ; instrumentation ; methods ; standards ; Hemoglobins ; analysis ; Humans ; Leukocyte Count ; instrumentation ; Platelet Count ; instrumentation ; Quality Control ; Reference Standards ; Weights and Measures
10.Evaluation of enzymatic method for determination of serum beta-hydroxybutyrate and its clinical application.
Feng-qin REN ; Sheng-kai YAN ; Da-yong MAO ; Yu-xiu LI ; Xin-hua XIAO ; Er-mu XU
Acta Academiae Medicinae Sinicae 2003;25(6):702-705
OBJECTIVETo evaluate an enzymatic method for determining serum beta-hydroxybutyrate (beta-HB) with the National Committee for Clinical Laboratory Standards (NCCLS) projects, and to discuss its clinical values in diabetic ketoacidosis (DKA).
METHODSThe precision, accuracy, specificity, linearity and interference of the enzymatic method were analyzed. This method was used to determine serum beta-HB in 60 cases of normals, 50 cases of diabetes, and 34 cases of DKA by autochemistry analyzer.
RESULTSEnzymatic beta-HB assay was precise (within-run CV, day-to-day CV, and total CV < 5%). The linearity studies showed the method was linear up to 4 mmol/L. Recovery rate was 98.5%-104.1%. Hemolysis (Hemoglobin up to 18.2 g/L), icteric samples with total bilirubin up to 224 mumol/L, and lipemia up to triglyceride concentration of 2.28 mmol/L did not interfere with the beta-HB results in this method. Serum beta-HB levels were significantly elevated in DKA patients compared with DM patients and controls (P < 0.01). Positive rate of serum beta-HB in DKA patients was significantly higher than that of urinary ketone (P < 0.05).
CONCLUSIONSEnzymatic method is convenient and reliable, allows full automation, and is rapid enough to be used for both routine and urgent determinations of serum beta-HB. It can be used in diagnosing and monitoring treatment of DKA.
3-Hydroxybutyric Acid ; blood ; Adolescent ; Adult ; Autoanalysis ; Diabetes Mellitus ; blood ; Diabetic Ketoacidosis ; blood ; Evaluation Studies as Topic ; Female ; Humans ; Male ; Middle Aged