1.Pitfalls and sources of error of color duplex ultrasonography in detecting deep vein thrombosis of proximal lower extremities
Jing GAO ; Lianhua YI ; Ho Yong Auh
Chinese Journal of Medical Imaging Technology 2004;20(3):472-476
Purpose To analyze the sources of errors and discuss the techniques to eliminate pitfalls in detecting deep vein thrombosis (DVT) of the proximal lower extremities with color duplex ultrasonography (CDUS). Methods Sixty-eight cases with initial and repeat venous CDUS of the proximal lower extremities were retrospectively reviewed. The repeat was done within 24 hours after initial CDUS scanning. Comparing repeated images to initial ones, the pitfalls and sources of error in CDUS of the proximal lower extremities were discussed. Results In total 68 repeat studies, there were 62 results as same as initials and 4 cases of false negative DVT and 2 cases of false positive DVT. Conclusion Venous CDUS in detecting DVT is observer dependent. Some pitfalls and errors can be eliminated and corrected with proper scan techniques. CDUS is the most valuable imaging modality for assessing suspected DVT in the proximal lower extremities.
2.Hepatic Microabscess with Ascending Cholangitis Complicated by Endoscopic Retrograde Cholangiopancreatogram (ERCP): A Case Report.
Mi Young KIM ; Moon Gyu LEE ; Yong Ho AUH
Journal of the Korean Radiological Society 1994;31(1):131-133
Complicated hepatic microabscess secondary to ascending cholangitis following ERCP (Endoscopic retrograde cholangiopancreatogram) is rare, and needs to be differentiated from other microabscesses, metastasis or Caroli's disease. We experienced a case of hepatic microabscess associated with septic cholangitis following ERCP. Cholangiogram showed multiple sac-like abscess pockets with characteristic biliary communication, and CT scan revealed multiple low attenuated lesions. At the resolving stage of chotangitic microabscess, CT scan showed partial rim enhancement of the abscesses and disproportional dilatation of intrahepatic ducts. The residual parenchymal enhancement surrounding the resolved microabscess pockets and dilatated biliary ducts, however, remained even after clinical recovery.
Abscess
;
Caroli Disease
;
Cholangiopancreatography, Endoscopic Retrograde
;
Cholangitis*
;
Dilatation
;
Neoplasm Metastasis
;
Tomography, X-Ray Computed
3.Diagnosis of Budd-Chiari Syndrome by Measuring the Diameter of Azygos-hemiazygos Vein on CT.
Moon Gyu LEE ; Yong Ho AUH ; Cheol Min PARK ; Gi Young KO ; Sang Hee CHOI
Journal of the Korean Radiological Society 1995;32(5):763-767
PURPOSE: The diagnosis of Budd-Chiari syndrome on CT is difficult if CT do not demonstrate obstruction of the IVC or hepatic vein and other parameter is needed for the correct diagnosis. The purpose of our study was to determine the usefulness of measuring the diameter of azygos-hemiazygos vein on CT to differentiate Budd-Chiari syndrome from advanced liver cirrhosis. MATERIALS AND METHODS: Fourteen patients who were proven as Budd-Chiari syndrome on vena cavography were studied for analysis. All patients showed evidence of liver cirrhosis on CT. As a control group fifteen cases of advanced liver cirrhosis who underwent endoscopic sclerotheraphy due to esophageal variceal bleeding were also included for comparison. The largest short axis diameter of azygos-hemiazygos vein was measured in all patients at the level of diaphragm on axial CT and the results were compared in both groups. RESULTS: In patients with Budd-Chiari syndrome the largest short axial diameter of azygos-hemiazygos vein ranged from 0.5cm to 2.5cm(mean ;1.5cm). Only one patient who showed hepatic venous obstruction demonstrated a diameter of less than 1 cm(0. Scm). In contrast, the diameter in patients with advanced liver cirrhosis without obstruction of IVC or hepatic vein was less than 1 cm with a range from 0.2cm to 1 cm(mean ;0.6cm). CONCLUSION: The short axis diameter of azygos-hemiazygos vein was an indicator of IVC obstruction (Budd-Chiari syndrome).
Axis, Cervical Vertebra
;
Budd-Chiari Syndrome*
;
Diagnosis*
;
Diaphragm
;
Esophageal and Gastric Varices
;
Hepatic Veins
;
Humans
;
Liver Cirrhosis
;
Veins*
4.MR Features of Common Hepatic Duct Cholangiocarcinoma.
Mi Young KIM ; Yong Ho AUH ; Moon Gym LEE ; Dong Erk GOO ; Hyeon Kweun HA
Journal of the Korean Radiological Society 1994;30(4):687-691
PURPOSE: The role of MRI in the detection of cholangiocarcinoma of the common hepatic duct has rarely been described. This study was attempted to ascertain characteristic MR features of cholangiocarcinoma. MATERIALS AND METHODS: The T1(500/30, TRs/TEs) and T2 weighted(200/80, TRs/TEs) MR images were obtained from nine patients with cholangiocarcinoma of the common hepatic duct. The common hepatic lesions were detected in seven cases. MR features of cholangiocarcinoma were analysed according to the signal intensity and associated findings. RESULTS: The seven cases showed lower signal intensity than the surrounding normal liver parenchyma on T1 weighted image. On T2 weighted image, the tumor showed isosignal intensity and hyperintensity in four and three patients, respectively. T2 image also revealed diffusely increased signal intensity in some hepatic lobe or segment in four cases, and Intrahepatic periductal high signal intensity in one case. Other associated MR findings were intrahepatic metastasis, and intratumoral hemorrhage, each noted in a different case. CONCLUSION: T2 weighted Image appears to be effective in the detection of cholangiocarcinoma of the common hepatic duct and evaluation of its associated intrahepatic lesions.
Cholangiocarcinoma*
;
Hemorrhage
;
Hepatic Duct, Common*
;
Humans
;
Liver
;
Magnetic Resonance Imaging
;
Neoplasm Metastasis
5.Acupuncture needles in the abdominal organs: features on plain radiography, US and CT.
Seung Yon BAEK ; Moon Gyu LEE ; Hye Young CHOI ; Kyoung Sik CHO ; Yong Ho AUH
Journal of the Korean Radiological Society 1992;28(4):589-592
Acupuncture with gold needle insertion is utilized in Oriental medicine, and the effect of therapy is represented by anti-inflammatory and analgesic function, But sometimes the needle is erroneously inserted into abdominal organs, and then it may cause dangerous complications. We report a case of multiple gold needles in the abdominal organs without having definete clinical symptoms.
Acupuncture*
;
Medicine, East Asian Traditional
;
Needles*
;
Radiography*
6.Stomach cnacer with ureteral metastasis: CT findings and mode of metastasis.
Hye Young CHOI ; Kyoung Sik CHO ; Moon Gyu LEE ; Yong Ho AUH
Journal of the Korean Radiological Society 1992;28(3):407-412
No abstract available in English.
Neoplasm Metastasis*
;
Stomach*
;
Ureter*
7.Insulinoma: nonvisualization on MR.
Seung Yon BAEK ; Moon Gyu LEE ; Kyu Bo SUNG ; Kyoung Sik CHO ; Yong Ho AUH
Journal of the Korean Radiological Society 1991;27(6):817-820
No abstract available.
Insulinoma*
8.CT feature of bile duct invasion in hepatocellular carcinoma.
Mi Young KIM ; Moon Gyu LEE ; Yong Ho AUH ; Jae Hoon LIM ; Ki Whang KIM
Journal of the Korean Radiological Society 1992;28(5):739-743
Intra- and extrahepatic bile duct can be invaded by hepatocellular carcinoma (HCC). This is infrequent in HCC, but it can directly affect the clinical manifestation and prognosis. We present eight cases of HCCs with emphasis on the incidence and features of bile duct invassion on computed tomography (CT). Over a period of 22 months, abdominal CT was performed in 186 with HCC patients. Out of these, five cases of bile duct invasion by HCC were confirmed in our hospital and three in other hospitals. The eight cases were evaluated for the type, size and location. CT features of intraductal mass and ductal dilatation were evaluated. The incidence of bile duct invasion in HCC was 2.6%. Infiltrative type of HCC was seen in seven cases and six of these had mass 5-11 cm in size. The characteristic CT findings of bile duct invasion in HCC are mass in common hepatic duct with bulging contour(8/80, multiple intraductal masses in the intrahepatic ducts (5/8), and diffuse dilatation of intrahepatic ducts (7/8).
Bile Ducts*
;
Bile Ducts, Extrahepatic
;
Bile*
;
Carcinoma, Hepatocellular*
;
Dilatation
;
Hepatic Duct, Common
;
Humans
;
Incidence
;
Prognosis
;
Tomography, X-Ray Computed
9.Assessment of Resistive Index in Acute Epididymitis on Doppler Sonography.
Moon Gyu LEE ; Yong Ho AUH ; Kyoung Sik CHO ; Hyo Kyeong CHOI ; Seung Mun JUNG ; Chung Soo KIM
Journal of the Korean Radiological Society 1995;32(6):947-951
PURPOSE: This study was aimed to review findings of gray-scale ultrasonography and to assess the diagnostic value of the resistive index (RI) in patients with acute epididymitis by comparing with that in normal volunteers. MATERIALS & METHODS: Gray-scale ultrasonogram was reviewed in nine patients with acute epididymitis for echogenicity, size and reactive hydrocele. Normal values of resistive index (RI) were obtained in 20 epididymides from 10 volunteers (aged 20-28, mean 23.7). Nine patients of epididymitis (aged 18-67, mean 37.2) were examinated with color Doppler sonography and RI was measured at 11 sites on epididymal arteries. For the prediction of acute epididymitis, accuracy, sensitivity and specificity were calculated at the cut-off value of RI in 0.65 and 0.70. RESULTS: Gray-scale ultrasonography showed echogenicity that was variable among the 9 cases (hype- rechoic 2 cases, isoechoic 2, hypoechoic 5), enlargement of epididymis in 8, and reactive hydrocele in 8 cases. Normal volunteers displayed color Doppler signals in 14 out of 20. The range of RI in normal volunteers were between 0.64 and 1.00 (mean, 0.79 +/- SD 0.10). In patients with acute epididymitis, color Doppler signals were detected in all patients. The range of RI in epididymitis were 0.40-0.68 (mean, 0.56 +/- SD 0.10). At cut-off RI value of 0.65, accuracy was 88%, sensitivity 81.8%, and specificity 92.7%. At cut-off value of 0.70, accuracy was 92%, sensitivity 100%, and specificity 85.7%. CONCLUSION: In addition to the findings of gray-scale ultrasonography, resistive index and color flow changes are valuable in diagnosing acute epididymitis.
Arteries
;
Epididymis
;
Epididymitis*
;
Healthy Volunteers
;
Humans
;
Male
;
Reference Values
;
Sensitivity and Specificity
;
Ultrasonography
;
Volunteers
10.CT evaluation of colon carcinoma: Emphasis on distant lymph node invasion and liver metastases.
Kyung Il CHUNG ; Kyoung Sik CHO ; Moon Gyu LEE ; Seung Yeon BAEK ; Yong Ho AUH ; Jin Cheon KIM
Journal of the Korean Radiological Society 1993;29(1):118-125
Even though the value of computed tomography (CT) used to detect the colon carcinoma with minimal invasion is limited, its usefulnes sin the evaluation of the extent of disease such as hepatic metastasis or distant lymph node invasion has been emphasized. To examine the role of CT in the evaluation of colon carcinoma, CT scans obtained during the past 2 years in 56 patients with surgically proven colon carcinoma were reviewed and the findings correlated with pathologic results. The sensitivity and accuracy of CT for pericolic fat infiltration were 86, 58 and 80% respectively. Those of regional node were 60, 83 and 75% and distant node 67, 100 and 95%. Liver metastases showed sensitivity, specificity and accuracy of 83, 98, 96% and peritoneal metastases 67, 94 and 89% respectively. CT detected local invasion with fair degree of accuracy but the true value of CT lie in the detection of distant invasions such as liver and distant lymph node metastases thereby leading to preclusion of unnecessary procedures and implementation of appropriate precedures.
Colon*
;
Humans
;
Liver*
;
Lymph Nodes*
;
Neoplasm Metastasis*
;
Sensitivity and Specificity
;
Tomography, X-Ray Computed
;
Unnecessary Procedures