1.Tuberculous Aneurysm of the Abdominal Aorta: Endovascular Repair Using Stent Grafts in Two Cases.
Wei Chiang LIU ; Byung Kook KWAK ; Kyo Nam KIM ; Soon Yong KIM ; Joung Joo WOO ; Dong Jin CHUNG ; Ju Hee HONG ; Ho Sung KIM ; Chang Jun LEE ; Hyung Jin SHIM
Korean Journal of Radiology 2000;1(4):215-218
Tuberculous aneurysm of the aorta is exceedingly rare. To date, the standard therapy for mycotic aneurysm of the abdominal aorta has been surgery involving in-situ graft placement or extra-anatomic bypass surgery followed by effective anti-tuberculous medication. Only recently has the use of a stent graft in the treat-ment of tuberculous aortic aneurysm been described in the literature. We report two cases in which a tuberculous aneurysm of the abdominal aorta was success-fully repaired using endovascular stent grafts. One case involved is a 42-year-old woman with a large suprarenal abdominal aortic aneurysm and a right psoas abscess, and the other, a 41-year-old man in whom an abdominal aortic aneurysm ruptured during surgical drainage of a psoas abscess.
Adult
;
Aneurysm, Infected/drug therapy/radiography/*surgery
;
Antitubercular Agents/therapeutic use
;
Aortic Aneurysm, Abdominal/drug therapy/radiography/*surgery
;
*Blood Vessel Prosthesis Implantation
;
Case Report
;
Female
;
Human
;
Male
;
Psoas Abscess/surgery
;
*Stents
;
Tuberculosis, Cardiovascular/drug therapy/radiography/*surgery
2.A Case of Angiographic Embolization of Aortoenteric Fistula Caused by Endovascular Stent Grafting for an Abdominal Aortic Aneurysm.
Kwang Hun KO ; Seul Young KIM ; Il Soon JUNG ; Kyu Seop KIM ; Hee Seok MOON ; Jae Kyu SEONG ; Hyun Yong JEONG
The Korean Journal of Gastroenterology 2013;61(4):230-233
Aortoenteric fistula (AEF) developed after treatment for an abdominal aortic aneurysm (AAA) is a rare but usually fatal complication. We report a rare case of AEF bleeding after endovascular stent grafting for AAA which was managed angiographically. An 81-year-old man presented with hematochezia and acute abdominal pain for 1 day ago. Four years ago, an aortic stent was implanted in the infrarenal aorta for AAA. Endoscopies were performed to evaluate the hematochezia. Evidence of gastrointestinal bleeding was observed, but a clear bleeding point was not detected on upper endoscopy and colonoscopy. Contrast-enhanced computed tomography performed subsequently showed that the bleeding point was located in the fourth portion of the duodenum as an AEF caused by an inflammatory process in the stent-graft. Intra-arterial angiography showed a massive contrast leakage into the bowel via a small fistula from around the aortic stent graft site. Embolization was successfully performed by injecting a mixture of glue and lipiodol into the AEF tract. The patient was discharged with no evidence of gastrointestinal bleeding after the embolization.
Aged, 80 and over
;
Angiography
;
Aortic Aneurysm, Abdominal/*therapy
;
Aortic Diseases/*etiology/radiography/therapy
;
Embolization, Therapeutic
;
Endoscopy, Gastrointestinal
;
Fistula/*etiology/radiography/therapy
;
Gastrointestinal Hemorrhage/therapy
;
Humans
;
Male
;
Stents/*adverse effects
;
Tomography, X-Ray Computed
3.Internal Iliac Artery Embolization during an Endovascular Aneurysm Repair with Detachable Interlock Microcoils.
Woo Chul KIM ; Yong Sun JEON ; Kee Chun HONG ; Jang Yong KIM ; Soon Gu CHO ; Jae Young PARK
Korean Journal of Radiology 2014;15(5):613-621
OBJECTIVE: The purpose of this study was to evaluate the effectiveness of detachable interlock microcoils for an embolization of the internal iliac artery during an endovascular aneurysm repair (EVAR). MATERIALS AND METHODS: A retrospective review was conducted on 40 patients with aortic aneurysms, who had undergone an EVAR between January 2010 and March 2012. Among them, 16 patients were referred for embolization of the internal iliac artery for the prevention of type II endoleaks. Among 16 patients, 13 patients underwent embolization using detachable interlock microcoils during an EVAR. Computed tomographic angiographies and clinical examinations were performed during the follow-up period. Technical success, clinical outcome, and complications were reviewed. RESULTS: Internal iliac artery embolizations using detachable interlock microcoils were technically successful in all 13 patients, with no occurrence of procedure-related complications. Follow-up imaging was accomplished in the 13 cases. In all cases, type II endoleak was not observed with computed tomographic angiography during the median follow-up of 3 months (range, 1-27 months) and the median clinical follow-up of 12 months (range, 1-27 months). Two of 13 (15%) patients had symptoms of buttock pain, and one patient died due to underlying stomach cancer. No significant clinical symptoms such as bowel ischemia were observed. CONCLUSION: Internal iliac artery embolization during an EVAR using detachable interlock microcoils to prevent type II endoleaks appears safe and effective, although this should be further proven in a larger population.
Aged
;
Aged, 80 and over
;
Aortic Aneurysm, Abdominal/radiography/*therapy
;
Blood Vessel Prosthesis Implantation
;
Embolization, Therapeutic
;
Female
;
Follow-Up Studies
;
Humans
;
Iliac Artery/*surgery
;
Male
;
Middle Aged
;
Retrospective Studies
;
Tomography, X-Ray Computed