1.Determination of Plasticizer DEHP Released from Medical Injection Equipment.
Jian ZHENG ; Minzhu WANG ; Wang ANYAN ; Pinghua XU ; Yin HAN ; Yan WEN ; Li ZHANG
Chinese Journal of Medical Instrumentation 2015;39(6):451-453
To established an effective GC-MS /MS method for the contents determination of the residual DEHP in injection equipment, and investigate the effect of the pretreatment on the measurement. To simulate the clinical conditions of use, under the condition of 37 degrees C balance extraction, extract liquor by chloroform extraction, then the extract followed by analysis of GC-MS /MS. The method was simple, rapid, sensitive and accurate. The limits of quantitation (LOQ, S/N = 5) of cyclohexanone was 0.075 μg/mL, The spiked average recoveries ranged from 92% to 98%. The relative standard deviations (RSDs) of the method ranged from 1.01% to 1.61%, The method was simple, fast, sensitive and accurate, and may serve as a mass control method for residual DEHP in injection equipment.
Cyclohexanones
;
chemistry
;
Diethylhexyl Phthalate
;
chemistry
;
Equipment Contamination
;
Gas Chromatography-Mass Spectrometry
;
Injections
;
instrumentation
;
Limit of Detection
;
Plasticizers
;
chemistry
2.Analysis of the Results of ELISA by Detecting Low Quantitative HBsAg(CMIA)in Serums
Anyan DENG ; Yanjuan CAI ; Shourong ZHOU ; Qiang WANG ; Dongsheng WANG ; Guoyuan ZHANG ; Quming FAN ; Xiaolan GUO
Journal of Modern Laboratory Medicine 2015;(2):123-125
Objective To evaluate the performance of ELISA by detecting low quantitative HBsAg in serums.Methods 305 serum samples that the quantitation range was from 0.05 IU/ml to 9.99 IU/ml were collected,and then detected by ELISA. Results The rate of patients with low quantitation of HBsAg was 18.12% in patients with positive HBsAg.The total de-tected rate of ELISA was 87.87%,and the rate of 0.05~0.11,0.12~0.20,0.21 ~0.50,0.51 ~ 1.00,1.01~5.00 IU/ml and 5.01~9.99IU/ml were 36.00%,61.11%,78.38%,84.62%,99.11% and 100.00%,respectively.The differences were statistically significant between the detected rates of each group(χ2 =99.84,P =0.000).There was high correlation coeffi-cient between the results detected by ELISA and by CMIA(r = 0.874,P = 0.000).Conclusion The clinical laboratory should be careful to apply the method of ELISA to detect HBsAg for its missing detection in samples with low quantitation of HBsAg.
3.Expert consensus on 3D-printing template assisted CT-guided radioactive 125I seed implantation brachytherapy
Junjie WANG ; Shude CHAI ; Guangjun ZHENG ; Anyan LIAO ; Ping JIANG ; Yuliang JIANG ; Zhe JI
Chinese Journal of Radiological Medicine and Protection 2017;37(3):161-170
As an interstitial brachytherapy,radioactive seed implantation could provide high doses in the local site and minimal doses at surrounding normal tissues.It has become one of the best choice for early stage prostate carcinoma.Radioactive seeds were implanted under the guidance by ultrasound,CT and MRI,featured with surgical and interventional treatment.Based on dosimetry for target and organs at risk,radioactive seed implantation is multiple disciplinary.In order to acquire the accurate and high quality seed implantation,it is necessary to set up a team including surgeons,radiation oncologists,interventional doctors and nuclear medicine doctors.The content of the consensus is as follows:radiation physics and dosimetry,indications,side-effects and 3 D-printing template work-follow.Despite the benefit of radioactive seed implantation for solid carcinoma,there still a compelling need for prospective randomized and stage Ⅲ clinical trials from multiple centers,so as to upgrade the evidencebased level,above all confirm the role of radioactive seed implantation in the comprehensive treatment of tumors.
4.Research progress of experimental animals with sarcopenia
Chinese Journal of Primary Medicine and Pharmacy 2024;31(6):953-956
Sarcopenia is a disease characterized by age-related muscle mass reduction and functional decline. Animal experiments play a crucial role in studying the pathogenesis of sarcopenia. The correct selection of experimental animals is fundamental for establishing accurate animal models. Currently, there is no systematic summary of research on the selection of experimental animals for sarcopenia studies. This article provides a comprehensive overview of the selection of experimental animals for sarcopenia research to provide insights for future research in this area.
5.Determination of Plasticizer DEHP Released from Medical Injection Equipment
Jian ZHENG ; Minzhu WANG ; Anyan WANG ; Pinghua XU ; Yin HAN ; Yan WEN ; Li ZHANG
Chinese Journal of Medical Instrumentation 2015;(6):451-453
To established an effective GC-MS /MS method for the contents determination of the residual DEHP in injection equipment, and investigate the effect of the pretreatment on the measurement. To simulate the clinical conditions of use, under the condition of 37oC balance extraction, extract liquor by chloroform extraction, then the extract folowed by analysis of GC-MS /MS. The method was simple, rapid, sensitive and accurate. The limits of quantitation( LOQ, S/N = 5) of cyclohexanone was 0.075mg/mL, The spiked average recoveries ranged from 92% to 98%.The relative standard deviations( RSDs) of the method ranged from 1.01% to 1.61%, The method was simple, fast,sensitive and accurate,and may serve as a mass control method for residual DEHP in injection equipment.