1.Study of the relations between toxoplamosis and bronchial asthma.
Hong LIAO ; Long XU ; Yi-ming GUO ; Yi ZHAO ; Zhen-ying DING ; You-yuan ZENG ; Hong TANG ; Wen-yi ZHOU ; Song ZHANG ; Li-min ZHANG ; Wei WU ; Li ZHANG
Chinese Journal of Pediatrics 2003;41(6):470-470
Animals
;
Antibodies, Protozoan
;
analysis
;
Antigens, Protozoan
;
analysis
;
Asthma
;
blood
;
parasitology
;
Child
;
Child, Preschool
;
Female
;
Humans
;
Infant
;
Male
;
Toxoplasma
;
immunology
;
Toxoplasmosis
;
blood
2.IgG Western Blot for Confirmatory Diagnosis of Equivocal Cases of Toxoplasmosis by EIA-IgG and Fluorescent Antibody Test.
Imen KHAMMARI ; Fatma SAGHROUNI ; Alia YAACOUB ; Sondoss GAIED MEKSI ; Hinda ACH ; Lamia GARMA ; Akila FATHALLAH ; Moncef BEN SAID
The Korean Journal of Parasitology 2013;51(4):485-488
The performance values of available techniques used in serodiagnosis of toxoplasmosis are satisfactory but they raise problems of equivocal and discordant results for very low IgG titers. Recently marketed, LDBio-Toxo II IgG Western blot (IB) showed an excellent correlation with the dye test. We estimated the proportion of equivocal and discordant results between the enzyme immunoassay Platelia Toxo IgG (EIA-IgG) and fluorescent antibody test (FAT) and assessed the usefulness of the IB as a confirmatory test. Out of 2,136 sera collected from pregnant women, 1,644 (77.0%) tested unequivocally positive and 407 (19.0%) were negative in both EIA-IgG and FAT. The remaining 85 (4%) sera showed equivocal or discordant results. Among them, 73 (85.9%) were positive and 12 (14.1%) were negative in IB. Forty-one (89.1%) equivocal sera in EIA-IgG and 46 (86.8%) equivocal sera in FAT were positive in IB. Reducing the cut-off values of both screening techniques improved significantly their sensitivity in detecting very low IgG titers at the expense of their specificity. In conclusion, equivocal results in routine-used techniques and their discordance in determination of the immune status in pregnancy women were not uncommon. IB test appeard to be highly useful in these situations as a confirmatory technique.
Adult
;
Antibodies, Protozoan/*analysis/blood
;
Blotting, Western/*methods
;
Female
;
Fluorescent Antibody Technique/*methods
;
Humans
;
Immunoenzyme Techniques/*methods
;
Immunoglobulin M/*analysis/blood
;
Pregnancy
;
Pregnancy Complications, Parasitic/blood/*diagnosis
;
Toxoplasmosis/blood/*diagnosis
;
Young Adult
3.Probability of Antibody Formation against Circumsporozoite Protein of Plasmodium vivax among Korean Malaria Patients.
Ho Woo NAM ; Kyoung Ju SONG ; Hye Jin AHN ; Zhaoshou YANG ; Chom Kyu CHONG ; Pyo Yun CHO ; Seong Kyu AHN ; Tong Soo KIM
The Korean Journal of Parasitology 2014;52(2):143-149
To evaluate the seroprevalence against circumsporozoite protein (CSP) of Plasmodium vivax in sera of Korean patients, the central repeating domain (CRD) of CSP was cloned and analyzed. From the genomic DNA of patient's blood, 2 kinds of CSPs were identified to belong to a VK210 type, which is the dominant repeating of GDRA(D/A)GQPA, and named as PvCSPA and PvCSPB. Recombinantly expressed his-tagged PvCSPA or PvCSPB in Escherichia coli reacted well against sera of patients in western blot, with the detecting rate of 47.9% (58/121), which included 15 cases positive for PvCSPA, 6 cases positive for PvCSPB, and 37 cases for both. The mixture of PvCSPA and PvCSPB was loaded to a rapid diagnostic test kit (RDT) and applied with the same set of patient sera, which resulted in detection rates of 57.0% (69/121). When the protein sequences of PvCSPA were compared with those of P. vivax in endemic regions of India and Uganda, they were compatibly homologous to PvCSPA with minor mutations. These results suggested that the recombinant PvCSPA and PvCSPB loaded RDT may be a milestone in latent diagnosis which has been a hot issue of domestic malaria and important for radical therapy in overlapped infections with P. falciparum in tropical and subtropical areas. During the biological process of malarial infection, exposure of CSP to antigen-antibody reaction up to 57.0% is the first report in Korea.
Amino Acid Sequence
;
Antibodies, Protozoan/*blood/immunology
;
Antibody Formation
;
Antigens, Protozoan/immunology
;
Base Sequence
;
Humans
;
India
;
Malaria, Vivax/*diagnosis/*epidemiology/immunology
;
Merozoite Surface Protein 1/genetics/*immunology
;
Plasmodium vivax/genetics/immunology
;
Protozoan Proteins/genetics/*immunology
;
Reagent Kits, Diagnostic
;
Recombinant Proteins/diagnostic use/immunology
;
Republic of Korea/epidemiology
;
Sequence Analysis, DNA
;
Seroepidemiologic Studies
;
Uganda
4.Evaluation of a Novel Array-Based Toxoplasma, Rubella, Cytomegalovirus, and Herpes Simplex Virus IgG Enzyme Linked Immunosorbent Assay and Its Comparison with Virion/Serion Enzyme Linked Immunosorbent Assays.
Dongsheng WU ; Yuanjian WU ; Liuhong WANG ; Weidong XU ; Qiao ZHONG
Annals of Laboratory Medicine 2014;34(1):38-42
BACKGROUND: The dramatic increase in use of the IgG test for toxoplasma, rubella, cytomegalovirus (CMV), and herpes simplex virus (HSV) [TORCH] has led to the requirement for a high-efficiency method that can be used in the clinical laboratory. This study aimed to compare the results of BGI-Array ELISA TORCH IgG (BGI-GBI, China) screening method to those of Virion/Serion TORCH IgG ELISA (Virion/Serion, Germany). METHODS: Serum specimens (n=400) submitted for routine IgG testing by Virion/Serion ELISA were also tested using the BGI-Array ELISA method. The agreements of these two kinds of method were analyzed by kappa-coefficients calculation. RESULTS: Following repeat testing, the BGI-Array ELISA TORCH IgG assays demonstrated agreements of 99.5% (398/400 specimens), 98% (392/400 specimens), 99% (396/400 specimens), and 99.5% (398/400 specimens), respectively. The BGI-Array ELISA IgG assays provided results comparable to Virion/Serion ELISA results, with kappa-coefficients showing near-perfect agreement for the HSV (kappa=0.87), rubella (kappa=0.92) and CMV (kappa=0.93) and substantial agreement for the toxoplasma (kappa=0.80) IgG assays. The use of the BGI-Array ELISA TORCH IgG assays could reduce the turnaround time (1.5 hr vs. 5 hr by Virion/Serion ELISA for 100 specimens) and were easy to use. CONCLUSIONS: BGI-Array ELISA TORCH IgG shows a good agreement with Virion/Serion ELISA methods and is suitable for clinical application.
Antibodies, Viral/blood
;
Cytomegalovirus/immunology/*metabolism
;
*Enzyme-Linked Immunosorbent Assay
;
Humans
;
Immunoglobulin G/*analysis/blood
;
Protozoan Infections/diagnosis
;
Reagent Kits, Diagnostic
;
Rubella virus/immunology/*metabolism
;
Sensitivity and Specificity
;
Simplexvirus/immunology/*metabolism
;
Toxoplasma/immunology/*metabolism
;
Virion/*immunology/metabolism
;
Virus Diseases/diagnosis