1.A immune responses following different doses of Japanese encephalitis vaccine (Produced by National Institute of Hygiene and Epidemiology-NIHE)
Journal of Preventive Medicine 2000;10(3):38-42
262 children aged from 6 to 14 were randomly divided into 4 groups receiving different subcutaneous doses of Japanese encephalitis (JE) vaccine: 1 ml, 0.75ml, 0.5ml, or an intradermal dose of 0.1 ml. After primary vaccineation of 2 doses, sufficient protective immune response has been observed in all 4 groups, and GMT values rise after the booster dose. No significant statistical difference in sero-conversion rate was shown in the 4 groups
Immune System
;
Japanese Encephalitis Vaccines
2.Research to develop requirements of Viet Nam for chemical components of Japanese encephalitis (JE) vaccine
Journal of Preventive Medicine 1999;10(2):46-50
159 lots of JE vaccine, which produced from 1994 to 1999, have been tested for chemical components including total protein, thimerosal, formaldehyde and pH. All of the 159 lots meet the WHO's minimal requirements for JE vaccine. Basing on the obtained results, WHO's requirements for chemical components of JE vaccine can be used for JE vaccine produced in Vietnam.
Japanese Encephalitis Vaccines
;
chemistry
3.Cloning of yeast Pichia pastoris coded synthesis of HBsAg DNA recombinant
Journal of Preventive Medicine 2001;11(2):40-45
The DNA fragment in HBV genome, which codes for HBsAg, was reconstructed from oligodeoxynucleotides using PCR method. After checking for correct nucleotid sequences by DNA sequencing, the DNA fragment coding for HBsAg was ligated into the plasmid vector pPICZA. Restricted enzymes EcoR I and Noti were utilized to cut DNA - plasmid and positive clones containing HBsAg-coding DNA-plasmid were selected by agarose gel electrophoresis
Cloning, Organism
;
Hepatitis B Surface Antigens
;
DNA, Recombinant
4.Evaluation of the safety and immunogenicity of recombinant DNA hepatitis B vaccine (RecomBvax) producted by VABIOTECH
Journal of Preventive Medicine 2005;15(2):27-31
Recombinant DNA hepatitis B vaccine (RecomBvax)- produced by VABIOTECH -National Institute of Hygiene and Epidemiology was injected into 319 children from 3 to 6 years old living in 3 communes Thieu Long, Thieu Hung and Thieu Hop of Thieu Hoa district, Thanh Hoa province to evaluate quality of the vaccine in clinical. The results showed that RecomBvax vaccine have high safety and have not significant side effect. The incidence of positive immune response of 3 RecomBvax injections is 91,85% with GMT of 350.6mIU/ml while the protective concentration of antibody needed is 10mIU/ml. RecomBvax is highly safe and immunogenic response equivalent with rHbvax in the control group.
Hepatitis B
;
DNA, Vaccination
5.Assessment of knowledge and practices related to biosafety of researchers in microbiological laboratories of provincial centers for preventive medicine.
Dung Anh Nguyen ; Minh Binh Nguyen ; Cuong Tuan Ngo ; Thuy Thanh Nguyen ; Lien Thi Phuong Nguyen ; Mai Thi Phuong Le ; Tho Thi Thi Nguyen
Journal of Preventive Medicine 2007;17(6):64-69
Background: In recent years, due to the outbreak of new infectious diseases, re-emerging diseases and bio-terrorist threats, the biological safety for laboratories is essential\r\n', u'Objectives: to evaluate knowledge and practices related to biosafety of researchers in microbiological laboratories\r\n', u'Subjects and method: The study was carried out in the period 2006-2007. Questionnaires and checklists were used for the direct interview the knowledge and observe the practices related to biological safety of 97 laboratory technicians from microbiology laboratories of 22 provincial centers for preventive medicine, which represent for all areas in Vietnam.\r\n', u'Results: The percentage of technicians defines correctly the hazardous groups of some common pathogens are 8.2-33%. The percentage of technicians define correctly the transmission routes of Bacillus anthracis, Staphylococus, Streptococcus are 1%, 15% and 19.6%, respectively. The opinion that thay can wear the laboratory blouse out of laboratories, bring personal belongings into the laboratory and pipeting by mouth are 21.6%, 50.5% and 23.7%, respectively. Regarding laboratory practices: The percentage of technicians does not use gloves is 37.8%; pipeting by mouth: 22.6%. Over 40% technicians do not disinfect working area or washing hands with alcohol after experiments\r\n', u'Conclusion: The results of this study are a basis for planning programs to train, supervise and improve the operational quality of the microbiological laboratory of the provincial preventive health care centers.\r\n', u'\r\n', u'\r\n', u'
Health Knowledge
;
Attitudes
;
Practice
;
Biotechnology/ standards
;
Safety/ standards
;
6.Result of production of standard Albumin from human plasma.
Phan Trung Do ; Duong Tuan Pham ; Hien Thi Do ; Ha Diem Vo ; Thuy Thi Nguyen ; Thin Duy Ngo ; Phuc Hanh Hoang ; Tri Anh Nguyen
Journal of Medical Research 2007;52(5):1-6
Background: Human albumin was produced and used in many countries. Cohn's technique had been used to precipitate albumin from human plasma. This technique was easy and cheap and the quality of the product was good. In Vietnam, human albumin had to import, but the prices was very expensive. Vietnam was having good plasma in large quantity and high quality. That\u2019s why research on production plasma albumin was essential.\r\n", u"Objectives: This study aimed at using Cohn's technique improved by Drohan and Van - Aken to produce standard albumin from human plasma. Subjects and method: Human plasma detected VIII-factor was used for present study. Plasma \ufffd?albumin was precipitated by ethanol at low temperature and pH. The collected albumins have been liophilizated and storage at 40C. The quality and quantity of Albumin was evaluated by quantitative analysis and protein \ufffd?electrophoresis. Results: The 418g of albumin powder was produced from 16 liters of plasma detected F \ufffd?VIII. The quality of this albumin come up to standard (>95%) and quantity of albumin collected from one liter of this plasma was 26g. Conclusion: In the Vietnamese condition, the technique of Cohn can be used to produce standard albumin for treatment.\r\n", u'
Albumins/ standards
;
Plasma
;
7.Applied research into the production process of gama - Globulin from Human Plasma and Standard gama - Globulin with Rich of Anti \u2013 HBs
Phan Trung Do ; Duong Tuan Pham ; Hien Thi Do ; Thuy Thi Tran ; Thin Duy Ngo ; Phuc Hanh Hoang ; Hai Xuan Le ; Tri Anh Nguyen
Journal of Medical Research 2008;0(1):67-71
Introduction: The need for gama \u2013 globulin, especially gama - globulin - anti \u2013 HBs, is huge in Vietnam. A number of patients cannot to afford use them due to the high price as they are imported. Meanwhile, Vietnam has high quality input sources for producing gama \u2013 globulin. \r\n', u'Objectives: To study the production process of gama - Globulin from Human Plasma and Standard gama - Globulin with Rich of Anti \u2013 HBs. \r\n', u'Subjects and method: 168 samples of human plasma from voluntary blood donors, which had been screened with for transfusion transmittable infections (TTLs), were chosen as plasma with rich of anti - HBs. The plasma with anti - HBsAg was precipitated with ethanol 25%, pH 6,9 to gain gama - globulin with rich anti - HBs, which was dried by Dutch Ly - 3 - TTE machine. Activation of anti - HBs gama - globulin was identified by a standard method of the degree of antibody specific for anti - HBsAg kit of BIORAD, \r\n', u'Results: The purity of the gama - globulin achieved was 93%, which was almost equal with the results of some foreign researchers (7.8), the activation of anti - HBs was 1:128 dilution degree. The productivity of gama - globulin gaining from 1 litter plasma was 6.0 gram. This new issue was first demonstrated in Vietnam. \r\n', u'Conclusion: We can domestically produce anti-Bs gama - globulin with high degree of activeness (1:128) from human plasma by the precipitating method with ethanol, pH and low temperature. \r\n', u'
Human plasma
;
gama - globulin - anti - HBs
;
Precipitation of ethanol
;
pH and low temperature
8.Immunohistochemical expression of anaplastic lymphoma kinase in neuroblastoma and its relations with some clinical and histopathological features
Thu Dang Anh PHAN ; Thao Quyen NGUYEN ; Nhi Thuy TO ; Thien Ly THANH ; Dat Quoc NGO
Journal of Pathology and Translational Medicine 2024;58(1):29-34
Background:
Anaplastic lymphoma kinase (ALK) mutations have been identified as a prominent cause of some familial and sporadic neuroblastoma (NB). ALK expression in NB and its relationship with clinical and histopathological features remains controversial. This study investigated ALK expression and its potential relations with these features in NB.
Methods:
Ninety cases of NB at the Department of Pathology, University of Medicine and Pharmacy at Ho Chi Minh City, Viet Nam from 01/01/2018 to 12/31/2021, were immunohistochemically stained with ALK (D5F3) antibody. The ALK expression and its relations with some clinical and histopathological features were investigated.
Results:
The rate of ALK expression in NB was 91.1%. High ALK expression (over 50% of tumor cells were positive with moderate-strong intensity) accounted for 65.6%, and low ALK expression accounted for 34.4%. All the MYCN-amplified NB patients had ALK immunohistochemistry positivity, most cases had high ALK protein expression. The undifferentiated subtype of NB had a lower ALK-positive rate than the poorly differentiated and differentiated subtype. The percentages of ALK positivity were significantly higher in more differentiated histological types of NB (p = .024). There was no relation between ALK expression and: age group, sex, primary tumor location, tumor stage, MYCN status, clinical risk, Mitotic-Karyorrhectic Index, prognostic group, necrosis, and calcification.
Conclusions
ALK was highly expressed in NB. ALK expression was not related to several clinical and histopathological features. More studies are needed to elucidate the association between ALK expression and ALK gene status and to investigate disease progression, especially the oncogenesis of ALK-positive NB.
9.Evaluation of the positivity of the fecal occult blood test compared to the microscopic detection of red blood cells
Chi Cao LE ; Nu Phuong Anh TON ; Thi Minh Chau NGO ; Phuoc Vinh NGUYEN ; Thi Bich Thao DO ; Thi Ngoc Thuy HA ; Minh Tiep VO ; Thi Giang TRAN ; That Dong Duong TON
Hue Journal of Medicine and Pharmacy 2023;13(7):31-38
Backgrounds: Fecal occult blood testing (FOBT) is commonly used in colorectal cancer screening programs. Many studies have compared different FOBT methods, but the correlation between traditional red cell microscopy and FOBT remains unclear. Objectives: 1) To evaluate the rate of positive FOBT in patients with different disease groups; 2) To compare the sensitivity and specificity of red blood cells detection in fresh stool by microscopy technique and FOBT. Materials and methods: This was a cross-sectional study involving 120 patients from Hue University of Medicine and Pharmacy Hospital who requested a stool test from 4/2021 to 4/2022. Fresh stool samples were examined for the presence of red blood cells using traditional microscopy and FOBT technique. Results: The overall positivity rate of FOBT was 20%, and in the group of gastrointestinal diseases (n = 24), clinical anemia (n = 21), hepatobiliary diseases (n = 26) and other diseases (n = 49), it was 37.5%, 23.8%, 11.5% and 14.3%, respectively. In comparison with the FOBT technique, microscopic RBC detection had a sensitivity of 33.3% and a specificity of 100%. Conclusions: A high rate of fecal occult blood tests was observed in patients with gastrointestinal disorders. Microscopic erythrocyte detection has low sensitivity and many disadvantages compared to the rapid test. This rapid test should be widely used in clinical practice to aid in the diagnosis of gastrointestinal bleeding
10.Update on antibiotic resistance of common pathogenical bacteria isolated in Hue University of Medicine and Pharmacy Hospital
Dinh Binh TRAN ; Viet Quynh Tram NGO ; Thi Bao Chi LE ; Thi Chau Anh NGUYEN ; Hoang Bach NGUYEN ; Van Bao Thang PHAN ; Thi Khanh Linh NGUYEN ; Nu Xuan Thanh LE ; Thi Dang Khoa NGUYEN ; Thi Tuyen NGUYEN ; Thi Thuy UNG ; Thi Hai DINH ; Thi Ngoc Mai DUONG ; Minh Ngoc HOANG ; Viet Tu NGUYEN ; Le Bich Ngoc HOANG ; Tuan Khoi TRAN ; Doan Hieu TRAN ; Thi Tuyet Ngoc TRAN ; Van An LE
Hue Journal of Medicine and Pharmacy 2023;13(7):66-74
Backgroud: The aim of this study is to update on antibiotic resistance of common pathogenical bacteria isolated in Hue University of Medicine and Pharmacy Hospital (Hue UMP Hospital). Methodology: Use of the agar disk diffusion method to test the susceptibility to antimicrobial agents of 3709 bacterial strains from infected patients hospitalized in Hue UMP Hospital in 2020 - 2022. Results: Among 3709 strains of pathogenical bacteria isolated, S.aureus was found with the rate of 29.9%, followed by E. coli (24.5%), Pseudomonas aeruginasa (17.8%), Enterococcus spp. (11.8%), Klebsiella spp (9.7%) and Acinetobacter spp (4.1%). The proportion of bacterial isolates has changed, but Staphylococcus aureus is still highest rate. S.aureus is resistant to many antibiotics, but MRSA strains have decreased significantly, from 73.3% in 2020 to 62.5% in 2022. Pseudomonas aeruginosa was resistant to some of the group A recommended antibiotics such as ceftazidime, piperacillin-tazobactam with the rate of 56.6% and 48.7%. The percentage of E. coli with ESBL strains (+) was at 28.2% - 30.3%. Enterococus spp strains are still sensitive to vancomycin (83.1% - 91.9%). The rate of Klebsiella ESBL (+) is only 6.9% to 8.2%. The strains of Acinetobacter spp were highly resistant to Piperacillin (100%) and Ceftriaxone (96.5%) but they are still sensitive to imipenems 70 - 71%, highly sensitive to Doxycillin (95.2%) and Cefotaxime (88.4%). Conclusion: Many bacterial strains are resistant to many commonly antibiotics. Providing timely, regular, and effective management of antibiotic resistance patterns for common pathogenic bacteria in hospitals, will help reduce the risk of bacterial resistance.