3.Gadolinium Dimeglumine as a Contrast Agent for Digital Subtraction Angiography: in Vitro Hounsfield Unit Measurement and Clinical Efficacy.
Yonsei Medical Journal 2003;44(1):138-142
The purpose of this study was to evaluate the feasibility and safety of using gadolinium-chelates for digital subtraction angiography (DSA) in patients with contraindications to iodinated contrast material, and to assess the clinically effective concentration of gadolinium (Gd). Gadopentetate dimeglumine and iopromide were used in density measurements. Using 20 mL disposable syringes, serial dilutions of Gd and iopromide with saline were performed. Computed tomography scanning was done and the attenuation of each was recorded as mean Hounsfield units using region of interest analysis. Clinical trials were done in twelve patients with the following types of angiogram or intervention: hemodialysis access, percutaneous biliary drainage, percutaneous nephrostomy, cerebral angiography and transarterial chemoembolization (TACE) in hepatocellular carcinoma. The density of 1 : 1 diluted Gd was nearly equal to that of 1 : 4 dilution of iopromide, and that of pure Gd was similar to or less than that of 1 : 1 dilution of iopromide. Serum creatinine level was not elevated in any of the patients. Gd is a safe alternative agent in patients with contraindications to iodinated contrast materials. Pure Gd without dilution is the most clinically useful concentration.
Angiography, Digital Subtraction/*methods
;
*Contrast Media/adverse effects
;
Feasibility Studies
;
Gadolinium DTPA/adverse effects/*diagnostic use
;
Human
;
Safety
4.Hemodynamic effects and safety of pulmonary angiography in Chinese patients with pulmonary hypertension.
Hong-Liang ZHANG ; Yong WANG ; Zhi-Hong LIU ; Chang-Ming XIONG ; Xin-Hai NI ; Jian-Guo HE ; Qin LUO ; Zhi-Hui ZHAO ; Qing ZHAO ; Xing-Guo SUN
Chinese Medical Journal 2011;124(20):3232-3237
BACKGROUNDPulmonary angiography is widely performed in pulmonary hypertension patients, but its immediate effects on right heart hemodynamics and safety are not well known. The objective of this study was to investigate the right heart hemodynamic effects and safety of pulmonary angiography in Chinese patients with pulmonary hypertension.
METHODSBetween January 2008 and June 2009, pulmonary hypertension patients undergoing pulmonary angiography were consecutively enrolled. Pulmonary angiography was performed during breath-holding after deep breathing. The baseline clinical data, hemodynamic measurements before and after pulmonary angiography and complications occurring within 48 hours after angiography were recorded.
RESULTSNinety-five patients were included. All received non-ionic contrast medium with a volume of (75.7 ± 29.8) ml. Angiography reduced heart rate in patients with baseline mean pulmonary arterial pressure ≥ 60 mmHg (change of heart rate: (-3.1 ± 7.0) beats/min, P = 0.005), increased mean right atrial pressure, diastolic and end-diastolic right ventricular pressure in patients with baseline mean pulmonary arterial pressure < 60 mmHg (all P < 0.05). Patients with decreased mean pulmonary arterial pressure (change of mean pulmonary arterial pressure ≤ -10 mmHg) had the highest total pulmonary resistance (P = 0.009 vs. no change in mean pulmonary arterial pressure (change of mean pulmonary arterial pressure, -10 mmHg to 10 mmHg); P = 0.03 vs. increased mean pulmonary arterial pressure (change of mean pulmonary arterial pressure ≥ 10 mmHg)) and the lowest cardiac output (P = 0.018 vs. no change in mean pulmonary arterial pressure; P = 0.013 vs. increased mean pulmonary arterial pressure). There were 7 complications (7%), with 6 related to catheter and only 1 directly related to angiography. All complications were mild and no death occurred.
CONCLUSIONPulmonary angiography has minimal effect on right heart hemodynamics and is safe in pulmonary hypertension patients.
Adult ; Angiography ; adverse effects ; Contrast Media ; adverse effects ; Female ; Hemodynamics ; physiology ; Humans ; Hypertension, Pulmonary ; diagnostic imaging ; Male ; Middle Aged
5.Clinical characteristics of early and late drug-eluting stent in-stent restenosis and mid-term prognosis after repeated percutaneous coronary intervention.
Jian-Feng ZHENG ; Ting-Ting GUO ; Yuan TIAN ; Yong WANG ; Xiao-Ying HU ; Yue CHANG ; Hong QIU ; Ke-Fei DOU ; Yi-Da TANG ; Jin-Qing YUAN ; Yong-Jian WU ; Hong-Bing YAN ; Shu-Bin QIAO ; Bo XU ; Yue-Jin YANG ; Run-Lin GAO
Chinese Medical Journal 2020;133(22):2674-2681
BACKGROUND:
The mechanism and characteristics of early and late drug-eluting stent in-stent restenosis (DES-ISR) have not been fully clarified. Whether there are different outcomes among those patients being irrespective of their repeated treatments remain a knowledge gap.
METHODS:
A total of 250 patients who underwent initial stent implantation in our hospital, and then were readmitted to receive treatment for the reason of recurrent significant DES-ISR in 2016 were involved. The patients were categorized as early ISR (<12 months; E-ISR; n = 32) and late ISR (≥12 months; L-ISR; n = 218). Associations between patient characteristics and clinical performance, as well as clinical outcomes after a repeated percutaneous coronary intervention (PCI) were evaluated. Primary composite endpoint of major adverse cardiac events (MACEs) included cardiac death, non-fatal myocardial infarction (MI), or target lesion revascularization (TLR).
RESULTS:
Most baseline characteristics are similar in both groups, except for the period of ISR, initial pre-procedure thrombolysis in myocardial infarction, and some serum biochemical indicators. The incidence of MACE (37.5% vs. 5.5%; P < 0.001) and TLR (37.5% vs. 5.0%; P < 0.001) is higher in the E-ISR group. After multivariate analysis, E-ISR (odds ratio [OR], 13.267; [95% CI 4.984-35.311]; P < 0.001) and left ventricular systolic dysfunction (odds ratio [OR], 6.317; [95% CI 1.145-34.843]; P = 0.034) are the independent predictors for MACE among DES-ISR patients in the mid-term follow-up of 12 months.
CONCLUSIONS
Early ISR and left ventricular systolic dysfunction are associated with MACE during the mid-term follow-up period for DES-ISR patients. The results may benefit the risk stratification and secondary prevention for DES-ISR patients in clinical practice.
Coronary Angiography
;
Coronary Restenosis
;
Drug-Eluting Stents/adverse effects*
;
Humans
;
Percutaneous Coronary Intervention/adverse effects*
;
Prognosis
;
Treatment Outcome
6.Safety and efficacy of stent placement for treatment of intracranial aneurysms: a systematic review.
Peng-Fei YANG ; Qing-Hai HUANG ; Wen-Yuan ZHAO ; Bo HONG ; Yi XU ; Jian-Min LIU
Chinese Medical Journal 2012;125(10):1817-1823
OBJECTIVETo evaluate the safety and efficacy of stent placement for the treatment of complex intracranial aneurysms.
DATA SOURCESWe searched six databases, including Pubmed, Embase, SCI-expanded, the Cochrane Library, ISI Proceedings and ProQuest Dissertations & Theses for the relevant studies using multiple key words from December, 1997 to February, 2009.
STUDY SELECTIONThirty-three studies about stent placement for intracranial aneurysms were identified, which reported data from a total of 1069 patients with 1121 intracranial aneurysms.
DATA EXTRACTIONWe prepared a standardized data extraction form (DEF), which was used by two independent researchers to extract data from the included 33 studies.
RESULTSThe overall initial complete occlusion rate was 52.5% (456/869, 95%CI: 49.2% - 55.8%). The overall complication rate was 14.3% (162/1130, 95%CI: 12.3% - 16.4%), of which 3.6% (38/1044, 95%CI: 2.5% - 4.8%) were permanent. Clinical follow-up showed a dependence rate of 8.4% (39/465, 95%CI: 5.9% - 10.9%). Angiographic follow-up showed an improvement rate of 24.3% (117/481, 95%CI: 20.5% - 28.2%) and a recurrence rate of 12.9% (62/481, 95%CI: 9.9% - 15.9%). Chi-squared tests were performed to compare the following subgroups: self-expandable vs. balloon-expandable stents, unruptured vs. acutely ruptured aneurysms, and with vs. without pre-medication. Statistical significance was reached in eight tests.
CONCLUSIONSIntracranial stent is a safe and effective tool for embolizing complex intracranial aneurysms. Self-expandable stents are significantly easier and safer than balloon-expandable stents with respect to navigation and deployment through the tortuous cerebral vasculature. Patients with acutely ruptured aneurysms are more likely to be dependent, but not more likely to suffer more procedure-related complications.
Cerebral Angiography ; Embolization, Therapeutic ; methods ; Humans ; Intracranial Aneurysm ; diagnostic imaging ; therapy ; Stents ; adverse effects
7.Safety and feasibility of repeated percutaneous transradial coronary intervention in the same route.
Bin NIE ; Yu-Jie ZHOU ; Qing YANG ; Wan-Jun CHENG ; Zhi-Jian WANG ; Jian-Long WANG
Chinese Medical Journal 2012;125(2):221-225
BACKGROUNDThe radial approach has been increasingly used as an alternative to femoral access. And more procedures using repeated transradial coronary intervention (r-TRI) are performed. However, few data about r-TRI has been obtained. Therefore, we investigated the safety and feasibility of r-TRI using the same route.
METHODSA total of 423 consecutive eligible patients undergoing r-TRI were enrolled in the r-TRI group, and 846 patients with initial TRI (i-TRI) were assigned to the i-TRI group in a 2:1 matching ratio compared to r-TRI group. The primary endpoint included the success rate of the procedure and the incidence of vascular related complications.
RESULTSThe baseline clinical characteristics in the two groups were comparable. The success rate of procedures in the r-TRI and i-TRI was similar (96.0% vs. 97.5%, P = 0.130). In subgroup analysis (coronary angiography only or angiography with pecutaneous coronary intervention), similar results were also observed. The puncture numbers and incidence of radial artery spasm in the r-TRI group were significantly higher than in the i-TRI group (P = 0.024 and P < 0.001, respectively). The other procedural outcomes in the two groups were identical. With respect to the incidence of overall vascular related complication and independent events, there were no significant differences in spite of a higher incidence of radial artery occlusion (RAO) in the r-TRI group (RAO: 1.2% vs. 0.7%, P = 0.521). The patients in the i-TRI group had more comfortable feeling than patients in the r-TRI group (P = 0.001).
CONCLUSIONSR-TRI produces a comparable procedure success rate and incidence of vascular complication when compared to i-TRI. It should be considered as an acceptable and safe procedure.
Adult ; Aged ; Angioplasty, Balloon, Coronary ; adverse effects ; methods ; Coronary Angiography ; Female ; Humans ; Male ; Middle Aged
8.Clinical application of Neuroform Atlas stent-assisted coiling in the treatment of unruptured wide-neck intracranial aneurysms.
Jin Tao HAN ; Yu Xiang ZHANG ; Zi Chang JIA ; Chu Han JIANG ; Lian LIU ; Jing Yuan LUAN ; Fei LIANG ; Yan Qing ZHAO
Journal of Peking University(Health Sciences) 2023;55(1):139-143
OBJECTIVE:
To assess the safety and efficacy of Neuroform Atlas stent used in treatment of unruptured wide-neck intracranial aneurysms.
METHODS:
Clinical data of 62 patients with unruptured wide-neck intracranial aneurysms undergoing Neuroform Atlas stent-assisted coiling from August 2020 to September 2021 were retrospectively analyzed. There were 64 aneurysms in those 62 patients. Among them, 25 aneurysms were located at the bifurcation of M1 segment on middle cerebral artery, 16 at the anterior communicating artery, 10 at the C7 segment of internal carotid artery, 5 at the C6 segment of internal carotid artery, 4 at the apex of basilar artery, 3 at the A3 segment of anterior cerebral artery, and 1 at the M2 segment of middle cerebral artery. All the patients underwent Neuroform Atlas stent-assisted coiling, including 49 patients with single stent assisted coiling and 15 patients with dual stents assisted coiling (14"Y"style and 1"X"style). After the procedure, the immediate DSA was performed to evaluate the status of aneurysm occlusion and the parent artery patency. The clinical follow-up was performed 3 months after the operation and evaluated based on the modified Rankin Scale(mRS).DSA image was reviewed at 6 months after operation and Raymond grading scale was used to assess the status of aneurysm occlusion and the parent artery patency.
RESULTS:
A total of 62 patients with 64 aneurysms were all achieved technical success(100%).The immediate post-procedural Raymond scale was assessed, including Raymond Ⅰ in 57 aneurysms(89.1%, 57/64), Raymond Ⅱ in 6 aneurysms(9.3%, 6/64) and Raymond Ⅲ in 1 aneurysm(1.6%, 1/64). The peri-procedural complications rate was 4.8%(3/62), 2 patients developed intraoperative thrombosis and 1 patient suffered from local subarachnoid hemorrhage. Among them, 55 patients obtained 3 months clinical follow-up after operation and all the patients had good outcomes (mRS≤2), 50 patients with 52 aneurysms were followed up with DSA 6 months after operation, including Raymond Ⅰ in 45 aneurysms(86.5%, 45/52), Raymond Ⅱ in 4 aneurysms(7.7%, 4/52) and Raymond Ⅲ in 3 aneurysms(5.8%, 3/52).
CONCLUSION
Neuroform Atlas stent for the treatment of unruptured wide-neck intracranial aneurysms has high safety and good efficacy, and has its advantages over other traditional stents.
Humans
;
Intracranial Aneurysm/etiology*
;
Retrospective Studies
;
Treatment Outcome
;
Embolization, Therapeutic/methods*
;
Stents/adverse effects*
;
Cerebral Angiography
9.Effect of iohexol on the renal function in children undergoing cardiac angiography.
Xin-Ying ZHANG ; Yu-Lin WANG ; Xue-Lian ZHU
Chinese Journal of Contemporary Pediatrics 2009;11(11):935-936
Child
;
Child, Preschool
;
Contrast Media
;
adverse effects
;
Coronary Angiography
;
Female
;
Humans
;
Infant
;
Iohexol
;
adverse effects
;
Kidney
;
drug effects
;
physiology
;
Male
;
beta 2-Microglobulin
;
urine
10.Renal-related adverse effects of intravenous contrast media in computed tomography.
Kheng Song LEOW ; Yi Wei WU ; Cher Heng TAN
Singapore medical journal 2015;56(4):186-193
Renal-related adverse effects of intravascular contrast media (CM) include contrast-induced nephropathy in computed tomography and angiography. While large retrospective studies have been published, the exact pathogenesis of this condition is still unknown. We review the main international guidelines, including the American College of Radiology white paper and the guidelines of European Society of Urogenital Radiology, Royal College of Radiologists and Canadian Association of Radiologists, as well as their references, regarding this subject. We present a simplified, concise approach to renal-related adverse effects of CM, taking into consideration the basis for each recommendation in these published guidelines. This will allow the reader to better understand the rationale behind appropriate patient preparation for cross-sectional imaging.
Angiography
;
methods
;
Contrast Media
;
adverse effects
;
Drug-Related Side Effects and Adverse Reactions
;
Humans
;
Kidney Diseases
;
chemically induced
;
Tomography, X-Ray Computed
;
methods