1.Time-of-Flight Magnetic Resonance Angiography for Follow-Up of Coil Embolization with Enterprise Stent for Intracranial Aneurysm: Usefulness of Source Images.
Young Dae CHO ; Kang Min KIM ; Woong Jae LEE ; Chul Ho SOHN ; Hyun Seung KANG ; Jeong Eun KIM ; Moon Hee HAN
Korean Journal of Radiology 2014;15(1):161-168
OBJECTIVE: The aim of this study was to determine the interobserver and intermodality agreement in the interpretation of time-of-flight (TOF) MR angiography (MRA) for the follow-up of coiled intracranial aneurysms with the Enterprise stent. MATERIALS AND METHODS: Two experienced neurointerventionists independently reviewed the follow-up MRA studies of 40 consecutive patients with 44 coiled aneurysms. All aneurysms were treated with assistance from the Enterprise stent and the radiologic follow-up intervals were greater than 6 months after the endovascular therapy. Digital subtraction angiography (DSA) served as the reference standard. The degree of aneurysm occlusion was determined by an evaluation of the maximal intensity projection (MIP) and source images (SI) of the TOF MRA. The capability of the TOF MRA to depict the residual flow within the coiled aneurysms and the stented parent arteries was compared with that of the DSA. RESULTS: DSA showed stable occlusions in 25 aneurysms, minor recanalization in 8, and major recanalization in 11. Comparisons between the TOF MRA and conventional angiography showed that the MIP plus SI had almost perfect agreement (kappa = 0.892, range 0.767 to 1.000) and had better agreement than with the MIP images only (kappa = 0.598, range 0.370 to 0.826). In-stent stenosis of more than 33% was observed in 5 cases. Both MIP and SI of the MRA showed poor depiction of in-stent stenosis compared with the DSA. CONCLUSION: TOF MRA seemed to be reliable in screening for aneurysm recurrence after coil embolization with Enterprise stent assistance, especially in the evaluation of the SI, in addition to MIP images in the TOF MRA.
Angiography, Digital Subtraction/methods
;
Cerebral Angiography/methods
;
Embolization, Therapeutic/instrumentation/*methods
;
Female
;
Follow-Up Studies
;
Humans
;
Intracranial Aneurysm/diagnosis/radiography/*therapy
;
Magnetic Resonance Angiography/*methods
;
Male
;
Middle Aged
;
Observer Variation
;
Recurrence
;
Reference Standards
;
*Stents
2.Detection of Residual Brain Arteriovenous Malformations after Radiosurgery: Diagnostic Accuracy of Contrast-Enhanced Three-Dimensional Time of Flight MR Angiography at 3.0 Tesla.
Kyoung Eun LEE ; Choong Gon CHOI ; Jin Woo CHOI ; Byung Se CHOI ; Deok Hee LEE ; Sang Joon KIM ; Do Hoon KWON
Korean Journal of Radiology 2009;10(4):333-339
OBJECTIVE: Although three-dimensional time-of-flight magnetic resonance angiography (3D TOF-MRA) is used frequently as a follow-up tool to assess the response of arteriovenous malformations (AVMs) after radiosurgery, the diagnostic accuracy of 3D TOF-MRA is not well known. We evaluated the diagnostic accuracy of contrast-enhanced 3D TOF-MRA at 3.0 Tesla for the detection of residual AVMs. MATERIALS AND METHODS:This study included 32 AVMs from 32 patients who had been treated with radiosurgery (males/females: 21/11; average patient age, 33.1 years). The time interval between radiosurgery and MRA was an average of 35.3 months (range, 12-88 months). Three-dimensional TOF-MRA was obtained at a magnetic field strength of 3.0 Tesla after infusion of contrast media, with a measured voxel size of 0.40 x 0.80 x 1.4 (0.45) mm3 and a reconstructed voxel size of 0.27 x 0.27 x 0.70 (0.05) mm3 after zero-filling. X-ray angiography was performed as the reference of standard within six months after MRA (an average of two months). To determine the presence of a residual AVM, the source images of 3D TOF-MRA were independently reviewed, focusing on the presence of abnormally hyperintense fine tangled or tubular structures with continuity as seen on consecutive slices by two observers blinded to the X-ray angiography results. RESULTS: A residual AVM was identified in 10 patients (10 of 32, 31%) on X-ray angiography. The inter-observer agreement for MRA was excellent (kappa= 0.813). For the detection of a residual AVM after radiosurgery as determined by observer 1 and observer 2, the source images of MRA had an overall sensitivity of 100%/90% (10 of 10, 9 of 10), specificity of 68%/68% (15 of 22, 15 of 22), positive predictive value of 59%/56% (10 of 17, 9 of 16), negative predictive value of 100%/94% (15 of 15, 15 of 16) and diagnostic accuracy of 78%/75% (25 of 32, 24 of 32), respectively. CONCLUSION: The sensitivity of contrast-enhanced 3D TOF-MRA at 3.0 Tesla is high but the specificity is not sufficient for the detection of a residual AVM after radiosurgery.
Adult
;
Contrast Media
;
Female
;
Humans
;
Intracranial Arteriovenous Malformations/*diagnosis/*surgery
;
Magnetic Resonance Angiography/methods/*standards
;
Male
;
*Radiosurgery
;
Sensitivity and Specificity
3.Effect of Heart Rate and Coronary Calcification on the Diagnostic Accuracy of the Dual-Source CT Coronary Angiography in Patients with Suspected Coronary Artery Disease.
Lingdong MENG ; Lianqun CUI ; Yuntao CHENG ; Xiaoyan WU ; Yuansheng TANG ; Yong WANG ; Fayun XU
Korean Journal of Radiology 2009;10(4):347-354
OBJECTIVE: To evaluate the diagnostic accuracy of a dual-source computed tomography (DSCT) coronary angiography, with a particular focus on the effect of heart rate and calcifications. MATERIALS AND METHODS:One hundred and nine patients with suspected coronary disease were divided into 2 groups according to a mean heart rate (< 70 bpm and > or = 70 bpm) and into 3 groups according to the mean Agatston calcium scores (< or = 100, 101-400, and > 400). Next, the effect of heart rate and calcification on the accuracy of coronary artery stenosis detection was analyzed by using an invasive coronary angiography as a reference standard. Coronary segments of less than 1.5 mm in diameter in an American Heart Association (AHA) 15-segment model were independently assessed. RESULTS: The mean heart rate during the scan was 71.8 bpm, whereas the mean Agatston score was 226.5. Of the 1,588 segments examined, 1,533 (97%) were assessable. A total of 17 patients had calcium scores above 400 Agatston U, whereas 50 had heart rates > or = 70 bpm. Overall the sensitivity, specificity, positive predictive values (PPV) and negative predictive values (NPV) for significant stenoses were: 95%, 91%, 65%, and 99% (by segment), respectively and 97%, 90%, 81%, and 91% (by artery), respectively (n = 475). Heart rate showed no significant impact on lesion detection; however, vessel calcification did show a significant impact on accuracy of assessment for coronary segments. The specificity, PPV and accuracy were 96%, 80%, and 96% (by segment), respectively for an Agatston score less than 100% and 99%, 96% and 98% (by artery). For an Agatston score of greater to or equal to 400 the specificity, PPV and accuracy were reduced to 79%, 55%, and 83% (by segment), respectively and to 79%, 69%, and 85% (by artery), respectively. CONCLUSION: The DSCT provides a high rate of accuracy for the detection of significant coronary artery disease, even in patients with high heart rates and evidence of coronary calcification. However, patients with severe coronary calcification (> 400 U) remain a challenge to diagnose.
Calcinosis/*radiography
;
Coronary Angiography/methods/*standards
;
Coronary Disease/*radiography
;
Coronary Vessels/*pathology
;
Female
;
*Heart Rate
;
Humans
;
Male
;
Middle Aged
;
Predictive Value of Tests
;
Sensitivity and Specificity
;
Tomography, X-Ray Computed/methods/*standards
4.Cone beam computed tomography for vascular interventional radiology procedures: early experience.
Kang Min WONG ; Bien Soo TAN ; Manish TANEJA ; Sai Yan WONG ; Jiun Siong LOKE ; Shueh En LIN ; Richard Hg LO ; Kiat Beng TEO ; Kiang Hiong TAY
Annals of the Academy of Medicine, Singapore 2011;40(7):308-314
INTRODUCTIONCone beam computed tomography (CBCT) is a relatively new technological innovation that utilises fl at-panel detector technology to obtain CT-like images. The key strength of a CBCT system is that cross-sectional imaging can be obtained using the angiographic fl at panel unit without having to move the patient, allowing the radiologist to obtain soft tissue imaging during the procedure. This allows treatment planning, guidance, and assessment of outcome to be performed in one interventional suite.
MATERIALS AND METHODSFrom December 2008 to June 2009, 24 CBCT scans were performed during vascular interventional procedures on our department's newly installed multi-axis fl at panel angiographic unit.
RESULTSTen cases were performed for hepatic trans-arterial chemoembolisation, 9 cases for hepatic arterial Yttrium-90 infusion, while 5 cases were for other indications. CBCT was found to be useful in 20 of the 24 cases.
CONCLUSIONOur early experience showed that CBCT was useful in impacting decisions during selected vascular interventional procedures. As CBCT technology improves, we can foresee wider applications of this technology.
Aged ; Angiography ; Cone-Beam Computed Tomography ; standards ; Embolization, Therapeutic ; Female ; Humans ; Male ; Medical Audit ; Middle Aged ; Radiology, Interventional ; methods ; Retrospective Studies
5.CT Angiography for Living Kidney Donors: Accuracy, Cause of Misinterpretation and Prevalence of Variation.
Jee Won CHAI ; Whal LEE ; Yong Hu YIN ; Hwan Jun JAE ; Jin Wook CHUNG ; Hyeon Hoe KIM ; Jae Hyung PARK
Korean Journal of Radiology 2008;9(4):333-339
OBJECTIVE: To determine the accuracy of the use of multi-detector row CT (MDCT) to predict vascular anatomy in living kidney donors and to reveal the prevalence of vascular variations in a Korean population. MATERIALS AND METHODS: A total of 153 living kidney donors that had undergone preoperative CT and nephrectomy, either with open or laparoscopic surgery, were selected retrospectively. The initial CT results were compared with the surgical findings and repeated review sessions of CT scans were performed to determine the causes of mismatches in discordant cases. RESULTS: The accuracy of CT angiography was 95% to predict the number of renal vessels. Four arteries and two veins were missed during the initial CT interpretation due to perception errors (for two arteries and two veins) and technical limitations (two arteries). The prevalence of multiple renal arteries and veins, early branching of a renal artery and late confluence of a renal vein were 31%, 5%, 12%, 17%, respectively. The circumaortic renal vein and the bilateral inferior vena cava were found in two cases each (1.3%). One case (0.7%) each of a retroaortic renal vein and a supradiaphragmatic originated renal artery were found. CONCLUSION: MDCT provides a reliable method to evaluate the vascular anatomy and variations of living kidney donors.
Adult
;
Angiography/*methods/standards
;
Female
;
Humans
;
Kidney/*blood supply/radiography
;
*Living Donors
;
Male
;
Middle Aged
;
Renal Artery/radiography
;
Renal Veins/radiography
;
Retrospective Studies
;
*Tomography, X-Ray Computed/standards
;
Young Adult
6.Assessment of coronary flow reserve with transthoracic Doppler echocardiography: comparison with intracoronary Doppler method.
Soo Mi KIM ; Wan Joo SHIM ; Hong Euy LIM ; Gyo Seung HWANG ; Woo Hyuk SONG ; Do Sun LIM ; Young Hoon KIM ; Hong Seog SEO ; Dong Joo OH ; Young Moo RO
Journal of Korean Medical Science 2000;15(2):139-145
To evaluate the feasibility and usefulness of transthoracic Doppler echocardiography (TTDE) as a non-invasive method in recording distal anterior descending (LAD) coronary flow velocity, we compared coronary flow reserve (CFR) measured by TTDE with measurements by intracoronary Doppler wire (ICDW). Twenty-one patients without LAD stenosis were studied. ICDW performed at baseline and after intracoronary injection of 18 microg adenosine. TTDE was performed at baseline and after intravenous adenosine (140 microg/kgmin for 2 min). Adequate Doppler recordings of coronary flow velocities during systole were obtained in 14 of 21 study patients (67%) and during diastole in 17 (81%) patients. Baseline and hyperemic peak diastolic flow velocities measured by TTDE were significantly smaller than those obtained by ICDW (p<0.05). However, diminishing trends of diastolic and systolic velocity ratio after hyperemia were similarly observed in both methods. CFR obtained by TTDE (3.0+/-0.5), was higher than the value calculated by ICDW (2.5+/-0.4). There were significant correlations between the values obtained by the two methods (r=0.72, p<0.01). It is concluded that TTDE is a feasible method in measuring coronary flow velocity and appears to be a promising non-invasive method in evaluating CFR.
Adult
;
Aged
;
Blood Flow Velocity
;
Comparative Study
;
Coronary Angiography
;
Coronary Circulation*
;
Coronary Disease/ultrasonography*
;
Echocardiography, Doppler/standards
;
Echocardiography, Doppler/methods*
;
Female
;
Heart Rate
;
Human
;
Hyperemia/ultrasonography
;
Linear Models
;
Male
;
Middle Age
;
Prospective Studies
;
Reproducibility of Results
7.Review of the Current Status of Intra-Arterial Thrombolysis for Treating Acute Cerebral Infarction: a Retrospective Analysis of the Data from Multiple Centers in Korea.
Deok Hee LEE ; Dong Gyu NA ; Yon Kwon IHN ; Dong Joon KIM ; Eung Yeop KIM ; Yong Sun KIM ; Soo Mee LIM ; Hong Gee ROH ; Chul Ho SOHN
Korean Journal of Radiology 2007;8(2):87-93
OBJECTIVE: The purpose of the study was to review the current status of intra-arterial (IA) thrombolysis in Korea by conducting a retrospective analysis of the data from multiple domestic centers. MATERIALS AND METHODS: The radiologists at each participating institution were asked to fill out case report forms on all patients who had undergone IA recanalization due to acute anterior circulation ischemia. These forms included clinical, imaging and procedure-related information. A central reader analyzed the CT/MR and angiographic results. The rates of successful recanalization, hemorrhagic transformation and functional outcome were obtained. The univariate analyses were performed together with the multivariate analysis. RESULTS: We analyzed the data from 163 patients, and they had been treated at seven institutes. The initial imaging modalities were CT for 46 patients (28%), MR for 63 (39%), and both for 54 (33%). Various mechanical treatment methods were applied together in 50% of the patients. Radiologically significant hemorrhage was noted in 20/155 patients (13%). We found various factors that influenced the recanalization rate and the occurrence of significant hemorrhagic transformations. The favorable outcome rate, reported as modified Rankin Scale < or = 2, was 40%, and the mortality rate was 11%. The factors that predicted a poor functional outcome were old age (p = 0.01), initially severe neurological symptoms (p < 0.0001), MR findings of a wide distribution of lesions (p = 0.001), involvement of the basal ganglia (p = 0.01), performance of procedures after working hours (p = 0.01), failure of recanalization (p = 0.003), contrast extravasation after the procedure (p = 0.007) and significant hemorrhagic transformation (p = 0.002). The subsequent multivariate analysis failed to show any statistically significant variable. CONCLUSION: There was a trend toward increased dependency on MR imaging during the initial evaluation and increased usage of combined pharmacologic/mechanical thrombolysis. The imaging and clinical outcome results of this study were comparable to those of the previous major thrombolytic trials.
Acute Disease
;
Cerebral Angiography
;
Cerebral Infarction/diagnosis/*drug therapy
;
Female
;
Fibrinolytic Agents/*administration & dosage
;
Humans
;
Injections, Intra-Arterial
;
Logistic Models
;
Magnetic Resonance Imaging
;
Male
;
Middle Aged
;
Retrospective Studies
;
Thrombolytic Therapy/*methods/standards
;
Tomography, X-Ray Computed
;
Treatment Outcome