1.Manual Aspiration Technique to Retrieve a Prematurely Detached Coil during Cerebral Aneurysm Embolization.
David A STIDD ; Andrew K JOHNSON ; Demetrius K LOPES
Neurointervention 2014;9(1):21-25
Coil herniation, premature deployment, and fracture are procedure associated complications of endovascular aneurysm embolization that optimally necessitate coil retrieval when feasible. Several published techniques describe different strategies for managing coil complications including various snare retrieval devices, alligator retrieval devices, stent fixation, and open surgical resection of coils when distal blood flow is compromised. We report a novel technique employed to retrieve a prematurely detached coil during an aneurysm embolization using a syringe fixed to the microcatheter to carefully aspirate a loose coil with direct fluoroscopic visualization. This technique can only be utilized in the circumstance where the proximal end of the coil remains in the microcatheter. Conventional techniques of coil retrieval and stenting are discussed and compared to the rational for using the manual aspiration technique.
Alligators and Crocodiles
;
Aneurysm
;
Embolization, Therapeutic
;
Intracranial Aneurysm*
;
SNARE Proteins
;
Stents
;
Syringes
2.Progressive Deconstruction of a Distal Posterior Cerebral Artery Aneurysm Using Competitive Flow Diversion.
Andrew K JOHNSON ; Lee A TAN ; Demetrius K LOPES ; Roham MOFTAKHAR
Neurointervention 2016;11(1):46-49
Progressive deconstruction is an endovascular technique for aneurysm treatment that utilizes flow diverting stents to promote progressive thrombosis by diverting blood flow away from the aneurysm's parent vessel. While the aneurysm thromboses, collateral blood vessels develop over time to avoid infarction that can often accompany acute parent vessel occlusion. We report a 37-year-old woman with a left distal posterior cerebral artery aneurysm that was successfully treated with this strategy. The concept and rationale of progressive deconstruction are discussed in detail.
Adult
;
Aneurysm
;
Blood Vessels
;
Endovascular Procedures
;
Female
;
Humans
;
Infarction
;
Intracranial Aneurysm*
;
Parents
;
Posterior Cerebral Artery*
;
Stents
;
Subarachnoid Hemorrhage
;
Thrombosis
3.The correlation between carotid artery Doppler and stroke volume during central blood volume loss and resuscitation
Isabel KERREBIJN ; Sarah ATWI ; Mai ELFARNAWANY ; Andrew M. EIBL ; Joseph K. EIBL ; Jenna L. TAYLOR ; Chul Ho KIM ; Bruce D. JOHNSON ; Jon-Émile S. KENNY
Acute and Critical Care 2024;39(1):162-168
Using peripheral arteries to infer central hemodynamics is common among hemodynamic monitors. Doppler ultrasound of the common carotid artery has been used in this manner with conflicting results. We investigated the relationship between changing common carotid artery Doppler measures and stroke volume (SV), hypothesizing that more consecutively-averaged cardiac cycles would improve SV-carotid Doppler correlation. Methods: Twenty-seven healthy volunteers were recruited and studied in a physiology laboratory. Carotid artery Doppler pulse was measured with a wearable, wireless ultrasound during central hypovolemia and resuscitation induced by a stepped lower body negative pressure protocol. The change in maximum velocity time integral (VTI) and corrected flow time of the carotid artery (ccFT) were compared with changing SV using repeated measures correlation. Results: In total, 73,431 cardiac cycles were compared across 27 subjects. There was a strong linear correlation between changing SV and carotid Doppler measures during simulated hemorrhage (repeated-measures linear correlation [Rrm ]=0.91 for VTI; 0.88 for ccFT). This relationship improved with larger numbers of consecutively-averaged cardiac cycles. For ccFT, beyond four consecutively-averaged cardiac cycles the correlation coefficient remained strong (i.e., Rrm of at least 0.80). For VTI, the correlation coefficient with SV was strong for any number of averaged cardiac cycles. For both ccFT and VTI, Rrm remained stable around 25 consecutively-averaged cardiac cycles. Conclusions: There was a strong linear correlation between changing SV and carotid Doppler measures during central blood volume loss. The strength of this relationship was dependent upon the number of consecutively-averaged cardiac cycles.
4.The correlation between carotid artery Doppler and stroke volume during central blood volume loss and resuscitation
Isabel KERREBIJN ; Sarah ATWI ; Mai ELFARNAWANY ; Andrew M. EIBL ; Joseph K. EIBL ; Jenna L. TAYLOR ; Chul Ho KIM ; Bruce D. JOHNSON ; Jon-Émile S. KENNY
Acute and Critical Care 2024;39(1):162-168
Using peripheral arteries to infer central hemodynamics is common among hemodynamic monitors. Doppler ultrasound of the common carotid artery has been used in this manner with conflicting results. We investigated the relationship between changing common carotid artery Doppler measures and stroke volume (SV), hypothesizing that more consecutively-averaged cardiac cycles would improve SV-carotid Doppler correlation. Methods: Twenty-seven healthy volunteers were recruited and studied in a physiology laboratory. Carotid artery Doppler pulse was measured with a wearable, wireless ultrasound during central hypovolemia and resuscitation induced by a stepped lower body negative pressure protocol. The change in maximum velocity time integral (VTI) and corrected flow time of the carotid artery (ccFT) were compared with changing SV using repeated measures correlation. Results: In total, 73,431 cardiac cycles were compared across 27 subjects. There was a strong linear correlation between changing SV and carotid Doppler measures during simulated hemorrhage (repeated-measures linear correlation [Rrm ]=0.91 for VTI; 0.88 for ccFT). This relationship improved with larger numbers of consecutively-averaged cardiac cycles. For ccFT, beyond four consecutively-averaged cardiac cycles the correlation coefficient remained strong (i.e., Rrm of at least 0.80). For VTI, the correlation coefficient with SV was strong for any number of averaged cardiac cycles. For both ccFT and VTI, Rrm remained stable around 25 consecutively-averaged cardiac cycles. Conclusions: There was a strong linear correlation between changing SV and carotid Doppler measures during central blood volume loss. The strength of this relationship was dependent upon the number of consecutively-averaged cardiac cycles.
5.The correlation between carotid artery Doppler and stroke volume during central blood volume loss and resuscitation
Isabel KERREBIJN ; Sarah ATWI ; Mai ELFARNAWANY ; Andrew M. EIBL ; Joseph K. EIBL ; Jenna L. TAYLOR ; Chul Ho KIM ; Bruce D. JOHNSON ; Jon-Émile S. KENNY
Acute and Critical Care 2024;39(1):162-168
Using peripheral arteries to infer central hemodynamics is common among hemodynamic monitors. Doppler ultrasound of the common carotid artery has been used in this manner with conflicting results. We investigated the relationship between changing common carotid artery Doppler measures and stroke volume (SV), hypothesizing that more consecutively-averaged cardiac cycles would improve SV-carotid Doppler correlation. Methods: Twenty-seven healthy volunteers were recruited and studied in a physiology laboratory. Carotid artery Doppler pulse was measured with a wearable, wireless ultrasound during central hypovolemia and resuscitation induced by a stepped lower body negative pressure protocol. The change in maximum velocity time integral (VTI) and corrected flow time of the carotid artery (ccFT) were compared with changing SV using repeated measures correlation. Results: In total, 73,431 cardiac cycles were compared across 27 subjects. There was a strong linear correlation between changing SV and carotid Doppler measures during simulated hemorrhage (repeated-measures linear correlation [Rrm ]=0.91 for VTI; 0.88 for ccFT). This relationship improved with larger numbers of consecutively-averaged cardiac cycles. For ccFT, beyond four consecutively-averaged cardiac cycles the correlation coefficient remained strong (i.e., Rrm of at least 0.80). For VTI, the correlation coefficient with SV was strong for any number of averaged cardiac cycles. For both ccFT and VTI, Rrm remained stable around 25 consecutively-averaged cardiac cycles. Conclusions: There was a strong linear correlation between changing SV and carotid Doppler measures during central blood volume loss. The strength of this relationship was dependent upon the number of consecutively-averaged cardiac cycles.
6.The correlation between carotid artery Doppler and stroke volume during central blood volume loss and resuscitation
Isabel KERREBIJN ; Sarah ATWI ; Mai ELFARNAWANY ; Andrew M. EIBL ; Joseph K. EIBL ; Jenna L. TAYLOR ; Chul Ho KIM ; Bruce D. JOHNSON ; Jon-Émile S. KENNY
Acute and Critical Care 2024;39(1):162-168
Using peripheral arteries to infer central hemodynamics is common among hemodynamic monitors. Doppler ultrasound of the common carotid artery has been used in this manner with conflicting results. We investigated the relationship between changing common carotid artery Doppler measures and stroke volume (SV), hypothesizing that more consecutively-averaged cardiac cycles would improve SV-carotid Doppler correlation. Methods: Twenty-seven healthy volunteers were recruited and studied in a physiology laboratory. Carotid artery Doppler pulse was measured with a wearable, wireless ultrasound during central hypovolemia and resuscitation induced by a stepped lower body negative pressure protocol. The change in maximum velocity time integral (VTI) and corrected flow time of the carotid artery (ccFT) were compared with changing SV using repeated measures correlation. Results: In total, 73,431 cardiac cycles were compared across 27 subjects. There was a strong linear correlation between changing SV and carotid Doppler measures during simulated hemorrhage (repeated-measures linear correlation [Rrm ]=0.91 for VTI; 0.88 for ccFT). This relationship improved with larger numbers of consecutively-averaged cardiac cycles. For ccFT, beyond four consecutively-averaged cardiac cycles the correlation coefficient remained strong (i.e., Rrm of at least 0.80). For VTI, the correlation coefficient with SV was strong for any number of averaged cardiac cycles. For both ccFT and VTI, Rrm remained stable around 25 consecutively-averaged cardiac cycles. Conclusions: There was a strong linear correlation between changing SV and carotid Doppler measures during central blood volume loss. The strength of this relationship was dependent upon the number of consecutively-averaged cardiac cycles.