1.Endovascular Thrombectomy for Distal Occlusion Using a Semi-Deployed Stentriever: Report of 2 Cases and Technical Note
Yue WAN ; I Hsiao YANG ; Emanuele ORRU ; Timo KRINGS ; Anderson Chun On TSANG
Neurointervention 2019;14(2):137-141
Distal intracranial occlusions can sometimes cause significant neurological deficits. Endovascular thrombectomy in these vessels may improve outcome but carry a higher risk of haemorrhagic complications due to the small calibre and tortuosity of the target vessel. We report two cases of isolated M2/3 artery occlusion causing dense hemiplegia that was successfully treated with stent retrieval thrombectomy. A “semi-deployment technique” of a 3 mm stentriever was employed at the M2/3 bifurcation of the middle cerebral artery. Partial stent unsheathing allowed adequate clot engagement while avoiding excessive tension by the stent metal struts along the tortuous course of a distal vessel. Complete revascularization was achieved after first-pass of the stent retriever without complication, resulting in good clinical outcome in both cases. The described semi-deployment technique reduces the radial and tractional force exerted by the stentreiver on small branches, and may reduce the risk of vessel laceration or dissection in distal vessel thrombectomy.
Arteries
;
Endovascular Procedures
;
Hemiplegia
;
Lacerations
;
Middle Cerebral Artery
;
Stents
;
Stroke
;
Thrombectomy
;
Traction
2.Failure of Flow Diverter Treatment of Intracranial Aneurysms Related to the Fetal-type Posterior Communicating Artery.
Anderson Chun On TSANG ; Arthur Man Yuen FUNG ; Frederick Chun Pong TSANG ; Gilberto Ka Kit LEUNG ; Raymand LEE ; Wai Man LUI
Neurointervention 2015;10(2):60-66
PURPOSE: The pipeline embolization device (PED) is a flow diverter that has shown promise in the treatment of intracranial aneurysms. Close to one-fifth of aneurysms, however, fail to occlude after PED placement. This study aims to identify anatomical features and clinicopathologic factors that may predispose failed aneurysm occlusion with the PED. MATERIALS AND METHODS: We retrospectively reviewed all anterior circulation unruptured saccular aneurysms treated with the PED in a single-center. The primary outcome measure was angiographic occlusion. Anatomical features and potential predictors, including gender, aneurysm location, size, height, aspect ratio, neck width, prior treatment and the number of PED, were studied using binary logistic regression. RESULTS: 29 anterior circulation unruptured saccular aneurysms with a mean size of 6.99 mm treated with the PED in a single center were retrospectively studied. The overall occlusion rate was 79.3% after a mean follow-up of 9.2 months. Four aneurysms were related to the fetal-type posterior communicating artery (PComA), and all were refractory to flow diverter treatment. Female gender was significantly associated with a higher occlusion rate. We present the anatomical features and propose possible pathophysiological mechanisms of these PComA aneurysms that failed flow diverter treatment. CONCLUSION: A PComA aneurysm with persistent fetal-type circulation appears to be particularly refractory to flow diverter treatment, especially when the aneurysm incorporates a significant portion of the PComA. Our experience suggested that flow diverting stents alone may not be the ideal treatment for this subgroup of aneurysms, and alternative modalities should be considered. Female patients were found to have a significantly higher rate of treatment success.
Aneurysm
;
Arteries*
;
Female
;
Follow-Up Studies
;
Humans
;
Intracranial Aneurysm*
;
Logistic Models
;
Neck
;
Outcome Assessment (Health Care)
;
Retrospective Studies
;
Stents
3.Author Correction: MRI Vessel Wall Imaging and Treatment of an Aneurysm at the Atlanto-Axial Segment of an Aberrant Vertebral Artery.
Chun On Anderson TSANG ; Wan Lung Ryo YEUNG ; Ka Fung MAK ; Wai Man LUI
Neurointervention 2018;13(2):145-145
The originally published version of this Article contained an error in the author list: the last and first names of all authors are inverted.
4.MRI Vessel Wall Imaging and Treatment of an Aneurysm at the Atlanto-Axial Segment of an Aberrant Vertebral Artery.
Tsang Chun On ANDERSON ; Yeung Wan Lung RYO ; Mak Ka FUNG ; Lui Wai MAN
Neurointervention 2018;13(1):62-65
We report a case of unique location of an aneurysm at the atlanto-axial extradural segment of a unilateral aberrant vertebral artery. The MRI vessel wall imaging findings and possible mechanism of aneurysm formation were discussed. A 5 mm extracranial vertebral artery aneurysm located at the interlaminar space between C1 and C2 was diagnosed in a woman presenting with occipital headache. The index vertebral artery ran an aberrant course at the V3 segment, where it entered the dura between C1 and C2 instead of the usual atlanto-occipital space. MR vessel wall imaging showed homogenous wall enhancement of the aneurysm sac. We surmise the anomalous course of the vertebral artery subjected the V3 segment to repeated shearing force secondary to the atlanto-axial rotational neck movement. This led to vessel wall trauma and inflammation, and subsequent aneurysm formation. The aneurysm was successfully treated with endovascular coiling with resolution of symptoms.
Aneurysm*
;
Female
;
Headache
;
Humans
;
Inflammation
;
Magnetic Resonance Imaging*
;
Neck
;
Vertebral Artery*
5.Blood flow in intracranial aneurysms treated with Pipeline embolization devices: computational simulation and verification with Doppler ultrasonography on phantom models.
Anderson Chun On TSANG ; Simon Sui Man LAI ; Wai Choi CHUNG ; Abraham Yik Sau TANG ; Gilberto Ka Kit LEUNG ; Alexander Kai Kei POON ; Alfred Cheuk Hang YU ; Kwok Wing CHOW
Ultrasonography 2015;34(2):98-108
PURPOSE: The aim of this study was to validate a computational fluid dynamics (CFD) simulation of flow-diverter treatment through Doppler ultrasonography measurements in patient-specific models of intracranial bifurcation and side-wall aneurysms. METHODS: Computational and physical models of patient-specific bifurcation and sidewall aneurysms were constructed from computed tomography angiography with use of stereolithography, a three-dimensional printing technology. Flow dynamics parameters before and after flow-diverter treatment were measured with pulse-wave and color Doppler ultrasonography, and then compared with CFD simulations. RESULTS: CFD simulations showed drastic flow reduction after flow-diverter treatment in both aneurysms. The mean volume flow rate decreased by 90% and 85% for the bifurcation aneurysm and the side-wall aneurysm, respectively. Velocity contour plots from computer simulations before and after flow diversion closely resembled the patterns obtained by color Doppler ultrasonography. CONCLUSION: The CFD estimation of flow reduction in aneurysms treated with a flow-diverting stent was verified by Doppler ultrasonography in patient-specific phantom models of bifurcation and side-wall aneurysms. The combination of CFD and ultrasonography may constitute a feasible and reliable technique in studying the treatment of intracranial aneurysms with flow-diverting stents.
Aneurysm
;
Angiography
;
Computer Simulation
;
Endovascular Procedures
;
Hydrodynamics
;
Intracranial Aneurysm*
;
Stents
;
Ultrasonography
;
Ultrasonography, Doppler*
;
Ultrasonography, Doppler, Color