1.Successful Retrieval of a Fractured and Entrapped 0.035-Inch Terumo Wire in the Femoral Artery Using Biopsy Forceps.
Jun Hyuk KANG ; Seung Woon RHA ; Dae In LEE ; Sua KIM ; Jae Hyoung LEE ; Seung Hun KANG ; Sung Yoon LIM ; Byoung Geol CHOI ; Amro ELNAGAR ; Sun Won KIM ; Sung Il IM ; Seong Woo HAN ; Jin Oh NA ; Cheol Ung CHOI ; Hong Euy LIM ; Jin Won KIM ; Eung Ju KIM ; Chang Gyu PARK ; Hong Seog SEO ; Dong Joo OH
Korean Circulation Journal 2012;42(3):201-204
A 0.035-inch guide wire fracture and entrapment in a peripheral artery is a very rare complication, but when it does occur it may lead to life-threatening complications, such as perforation, thrombus formation, embolization, and subsequent limb ischemia. We describe our experience of successfully retrieving a fractured 0.035-inch Terumo guide wire in the external iliac artery using a biopsy forcep.
Angioplasty, Balloon, Coronary
;
Arteries
;
Biopsy
;
Extremities
;
Femoral Artery
;
Iliac Artery
;
Ischemia
;
Surgical Instruments
;
Thrombosis
2.Impact of Heterogeneous Overlapping Drug-Eluting Stents on the Arterial Responses of Rabbit Iliac Arteries: A Comparison With Overlapping Bare Metal Stents.
Seung Woon RHA ; Kang Yin CHEN ; Dong Joo OH ; Yong Jian LI ; Zhe JIN ; Kanhaiya Lal PODDAR ; Sureshkumar RAMASAMY ; Yoshiyasu MINAMI ; Amro ELNAGAR ; Byoung Geol CHOI ; Sang Pyo HONG ; Byoung Won CHEON ; Sang Ki MOON ; Sung Il IM ; Sun Won KIM ; Jin Oh NA ; Cheol Ung CHOI ; Hong Euy LIM ; Jin Won KIM ; Eung Ju KIM ; Seong Woo HAN ; Chang Gyu PARK ; Hong Seog SEO ; Jung Ha KIM ; Young Joon HONG ; Myung Ho JEONG
Korean Circulation Journal 2012;42(6):397-405
BACKGROUND AND OBJECTIVES: Although the use of heterogeneous overlapping drug-eluting stents (DES) is not uncommon in clinical practice, whether the implantation sequences of heterogeneous DES will influence the endothelialization or arterial responses differently remains unclear. MATERIALS AND METHODS: Twenty-one rabbits were randomized to receive overlapping stents in the iliac artery for 3 months {distal sirolimus-eluting stent (SES, Cypher(TM))+proximal paclitaxel-eluting stent (PES, Taxus(TM)) (C+T, n=7), distal Taxus+proximal Cypher (T+C, n=7) and bare metal stent (BMS)+BMS (B+B, n=7)}. Endothelial function was evaluated by the acetylcholine provocation test during follow-up angiography. Histopathological changes in proximal, overlapped, and distal stented segments were evaluated. RESULTS: Although the overall angiographic outcomes were comparable, late loss (mm) in the distal stented segment was higher in the B+B (0.39+/-0.07) and C+T (0.40+/-0.20) than that in the T+C (0.06+/-0.02) group (p<0.001). The incidence of acetylcholine-induced spasm was higher in the DES groups compared with BMS, regardless of the implantation sequences (85.7% in C+T vs. 14.3% in B+B vs. 71.4% in T+C, p=0.017). Notably, only the distal Cypher implantation group (C+T) had three cases of stent fracture. A histopathological analysis showed that despite similar arterial injury scores, Taxus and Cypher stents had higher inflammatory reactions at the overlapped and distal segments compared with those of BMS. CONCLUSION: Despite similar arterial injury, higher inflammatory reactions were observed in overlapping DES segments regardless of the implantation sequence compared with that of BMS. Moreover, DES was associated with impaired endothelial function on the adjacent non-stented segments.
Acetylcholine
;
Angiography
;
Drug-Eluting Stents
;
Endothelium
;
Follow-Up Studies
;
Iliac Artery
;
Incidence
;
Rabbits
;
Spasm
;
Stents
;
Taxus
;
Vasoconstriction