1.EFFECT OF GOLD ELECTRODEPOSIT ON THE BOND STRENGTH BETWEEN ALLOYS AND VENEERED RESIN.
Hong So YANG ; Yeong Joon PARK
The Journal of Korean Academy of Prosthodontics 1997;35(1):103-117
The purpose of this experiment was to determind whether the gold electrodeposit on Pd-Ag and Ni-Cr alloys influences on the shear bond strength between veneering resin and silicoated metal surface. All the metal specimens were sandblasted with 250microneter aluminum oxide and followed by silicoating and resin veneering. According to the metal surfaces to be veneered, experimental groups were divided into five. Group Prec : Gold alloy without gold coating Group Semi : Pd-Ag alloy without gold coating Group Base : Ni-Cr alloy without gold coating Group Semi-G : Pd-Ag alloy with gold coating Group Base-G : Ni-Cr alloy with gold coating All specimens were thermocycled 1,000 times at temperature of 5degrees C to 55degrees C. The effects of gold electrodeposit on the shear bond strength between resin and metal interface were measured and fractured surface of the resin veneered metal was examined under the scaning electron microscope. The following results were obtained 1. The shear bond strength between resin and metal was 64.51+/-11.11Kg/cm2in Prec group, 62.77+/-11.23Kg/cm2in Base group and 58.97+/-9.20 Kg/cm2in Semi Group. There was no significant difference among the groups. 2. The bond strength in groups Semi-G and Base-G decreased about 17%, compared to the non-gold-electrodeposit groups(Semi, Base). 3. In groups of non electrodeposit(Prec, Semi, Base), fracture occurred at the interface between alloy and resin, while fracture interface was observed between gold coating and resin in group Semi-G, and between metal substrate and gold coating in group Base-G resp[ectively.
Alloys*
;
Aluminum Oxide
2.Evaluation of shear bond strength of repair acrylic resin to Co-Cr alloy.
Safak KULUNK ; Tolga KULUNK ; Duygu SARAC ; Seda CENGIZ ; Seniha BABA
The Journal of Advanced Prosthodontics 2014;6(4):272-277
PURPOSE: The purpose of this study was to investigate the impact of different surface treatment methods and thermal ageing on the bond strength of autopolymerizing acrylic resin to Co-Cr. MATERIALS AND METHODS: Co-Cr alloy specimens were divided into five groups according to the surface conditioning methods. C: No treatment; SP: flamed with the Silano-Pen device; K: airborne particle abrasion with Al2O3; Co: airborne particle abrasion with silica-coated Al2O3; KSP: flamed with the Silano-Pen device after the group K experimental protocol. Then, autopolymerized acrylic resin was applied to the treated specimen surfaces. All the groups were divided into two subgroups with the thermal cycle and water storage to determine the durability of the bond. The bond strength test was applied in an universal test machine and treated Co-Cr alloys were analyzed by scanning electron microscope (SEM). Two-way analysis of variance (ANOVA) was used to determine the significant differences among surface treatments and thermocycling. Their interactons were followed by a multiple comparison' test performed uing a post hoc Tukey HSD test (alpha=0.05). RESULTS: Surface treatments significantly increased repair strengths of repair resin to Co-Cr alloy. The repair strengths of Group K, and Co significantly decreased after 6,000 cycles (P<.001). CONCLUSION: Thermocycling lead to a significant decrease in shear bond strength for air abrasion with silica-coated aluminum oxide particles. On the contrary, flaming with Silano-Pen did not cause a significant reduction in adhesion after thermocycling.
Alloys*
;
Aluminum Oxide
;
Water
4.Effects of the Er,Cr:YSGG laser on bone bed preparation with various laser tips.
Seong Kyun KIM ; Seong Joo HEO ; Jai Young KOAK ; Seong Doo HONG ; Shin Jae LEE ; Joo Hee LEE
The Journal of Korean Academy of Prosthodontics 2008;46(3):255-260
STATEMENT OF PROBLEM: Preparation of implant beds with lasers is considered a safe and reliable method, but the accuracy of this technique has not been examined. PURPOSE: The purpose of this study was to evaluate the accuracy and effectiveness of implant bed preparation using an Er,Cr:YSGG laser. MATERIAL AND METHODS: An Er,Cr:YSGG laser was applied to pig rib bone. The laser was employed at a 5.75 W power setting, 30 Hz/sec pulse repetition, and 70 micro sec pulse duration with 50 % water and 60% air spray. According to laser tips the groups were divided as follows; Group 1: paralleled - shaped sapphire tip (0.6 mm phi), Group 2: paralleled - shaped zirconia tip (0.6 mm phi), Group 3: tapered sapphire tip (0.4 mm phi). The Er,Cr:YSGG laser tip was separated by 1 mm from the bone and applied for 15 seconds in a non-contact mode. After the application, the bone was sectioned for specimens. Histologic measurements were determined by computerized morphometry. The length of the prepared bone surface was measured and the width of the entrance was measured. The results were analyzed with one-way ANOVA (P<0.05). RESULTS: The prepared length of group 3 was longer than that of group 2. The prepared bone width was larger than the width of the laser tip in every group. Additional bone removal was observed adjacent to the prepared area and displayed an irregular surface. CONCLUSION & DISCUSSION: Different cutting effects were observed according to the laser tip, emphasizing the importance of proper tip selection in the clinical setting. This preliminary study supported the existence of hydrokinetic effects.
Aluminum Oxide
;
Ribs
;
Water
;
Zirconium
5.BOND STRENGTH OF VARIOUS RESINS TO DENTURE TEETH BY SURFACE TREATMENT.
The Journal of Korean Academy of Prosthodontics 1999;37(1):42-50
This study investigated the effects of surface treatment for filling resins on the surface texture of denture resin teeth by the use of scanning electron microscope. This study also evaluated the bond strength of filling resins to denture resin teeth. The denture resin teeth in this study was Endura Posterio(Shofu Co., Japan). The filling resins used were Coe-cure(Coe Co., USA), Vertex RS (Dentimax Ziest, Holland), and light cured resin Z-100(3M Co., USA). The test sample were divided into 3 parts. Group 1 : Sandblasted with 50micrometer Aluminum oxide. Group 2 : Treated with #60 silicone carbide paper. Group 3 : Treated with monomer brush application. Control Group : No Treatment. The results were as follows; 1.The bond strength of filling resins to denture resin teeth is increased by surface treatment. 2.Regardless of the filling resins, there was a significant difference with # 60silicone carbide paper treated group. 3.Regardless of each group, the bond strength according to the filling resins were decreased in the following order: Vertex RS, Coe-cure and Z-100.
Aluminum Oxide
;
Dentures*
;
Silicones
;
Tooth*
6.Effect of surface treatments on shear bond strength of resin composite bonded to CAD/CAM resin-ceramic hybrid materials.
Merve Bankoğlu GÜNGÖR ; Seçil Karakoca NEMLI ; Bilge Turhan BAL ; Senem ÜNVER ; Aylin DOĞAN
The Journal of Advanced Prosthodontics 2016;8(4):259-266
PURPOSE: The purpose of this study was to assess the effect of surface treatments on shear bond strength of resin composite bonded to thermocycled and non-thermocycled CAD/CAM resin-ceramic hybrid materials. MATERIALS AND METHODS: 120 specimens (10×10×2 mm) from each material were divided into 12 groups according to different surface treatments in combination with thermal aging procedures. Surface treatment methods were airborne-particle abrasion (abraded with 50 micron alumina particles), dry grinding (grinded with 125 µm grain size bur), and hydrofluoric acid (9%) and silane application. According to the thermocycling procedure, the groups were assigned as non-thermocycled, thermocycled after packing composites, and thermocycled before packing composites. The average surface roughness of the non-thermocycled specimens were measured after surface treatments. After packing composites and thermocycling procedures, shear bond strength (SBS) of the specimens were tested. The results of surface roughness were statistically analyzed by 2-way Analysis of Variance (ANOVA), and SBS results were statistically analyzed by 3-way ANOVA. RESULTS: Surface roughness of GC were significantly lower than that of LU and VE (P<.05). The highest surface roughness was observed for dry grinding group, followed by airborne particle abraded group (P<.05). Comparing the materials within the same surface treatment method revealed that untreated surfaces generally showed lower SBS values. The values of untreated LU specimens showed significantly different SBS values compared to those of other surface treatment groups (P<.05). CONCLUSION: SBS was affected by surface treatments. Thermocycling did not have any effect on the SBS of the materials except acid and silane applied GC specimens, which were subjected to thermocycling before packing of the composite resin.
Aging
;
Aluminum Oxide
;
Hydrofluoric Acid
;
Methods
7.The effect of alumina and aluminium nitride coating by reactive magnetron sputtering on the resin bond strength to zirconia core.
Tolga KULUNK ; Safak KULUNK ; Seniha BABA ; Ozgur OZTURK ; Sengul DANISMAN ; Soner SAVAS
The Journal of Advanced Prosthodontics 2013;5(4):382-387
PURPOSE: Although several surface treatments have been recently investigated both under in vitro and in vivo conditions, controversy still exists regarding the selection of the most appropriate zirconia surface pre-treatment. The purpose of this study was to evaluate the effect of alumina (Al) and aluminium nitride (AlN) coating on the shear bond strength of adhesive resin cement to zirconia core. MATERIALS AND METHODS: Fifty zirconia core discs were divided into 5 groups; air particle abrasion with 50 microm aluminum oxide particles (Al2O3), polishing + Al coating, polishing + AlN coating, air particle abrasion with 50 microm Al2O3 + Al coating and air particle abrasion with 50 microm Al2O3 + AlN coating. Composite resin discs were cemented to each of specimens. Shear bond strength (MPa) was measured using a universal testing machine. The effects of the surface preparations on each specimen were examined with scanning electron microscope (SEM). Data were statistically analyzed by one-way ANOVA (alpha=.05). RESULTS: The highest bond strengths were obtained by air abrasion with 50 microm Al2O3, the lowest bond strengths were obtained in polishing + Al coating group (P<.05). CONCLUSION: Al and AlN coatings using the reactive magnetron sputtering technique were found to be ineffective to increase the bond strength of adhesive resin cement to zirconia core.
Adhesives
;
Aluminum Oxide*
;
Collodion
;
Resin Cements
;
Zirconium
8.A STDUY ON THE SURFACE MORPHOLOGY AND BOND STRENGTH OF DENTURE BASE RESIN TO COBALT-CHROMIUM ALLOY AFTER VARYING MODES OF SURFACE TREATMENT.
Mong Sook VANG ; Young Jon PARK
The Journal of Korean Academy of Prosthodontics 1997;35(1):78-94
The purpose of this experiment was to determine the effects of various treatments on denture base resin to metal bond for cobalt-chromium alloy. The metal surface was treated as follows. Group 1 : Sandblasted with 50microneter aluminum oxide. Group 2 : Sandblasted with 250microneter aluminum oxide. Group 3 : Sandblasted with 250microneter aluminum oxide and followed by silicoating. Group 4 : Electrochemically etched. Group 5 : treated with oxidizing solution. Group 6 : Beaded with 200microneter retention structure and followed by silicoating. All specimens were applied with 4-META resin and were thermocycled 1000 times at temperature of 5degrees C to 55degrees C. The effects of various surface treatments on the bond strength between 4-META resin and metal interface were measured by using the universal testing machine. All specimens were observed with SEM. The results were as follows 1. The bond strength of 4-META resin were significantly higher to Co-Cr alloy. 2. The bond strength decreased in the following orders : group 6, group 3, groups 1 and 2, group 4, group 5 and there was no statistically significant difference in bond strength among groups 1 and 2. (p>0.05) 3. The bond strength of cobalt-chromium alloy to 4-META resin were not significantly different. (p>0.05) 4. The treated surface of groups 1, 2 and 3 has more fine undercut than that of groups 4 and 5 with SEM. 5. Stable adhesion can be achieved when mechanically roughened metal surface by sandblasting than treating in an electrochemical etching and an oxidizing solution with potassium manganate.
Alloys*
;
Aluminum Oxide
;
Denture Bases*
;
Dentures*
;
Potassium
9.Effect of titanium surface roughness on adhesion and differentiation of osteoblasts.
Jung Sik KIM ; Jae Kwan LEE ; Sung Hee KO ; Heung Sik UM ; Beom Seok CHANG
The Journal of the Korean Academy of Periodontology 2005;35(4):839-850
The success of an implant is determined by its integration into the tissue surrounding the biomaterial. Surface roughness is considered to influence the behavior of adherent cells. The aim of this in vitro study was to determine the effect of surface roughness on Saos-2 osteoblast-like cells. Titanium disks blasted with 75 micrometer aluminum oxide particles and machined titanium disks were prepared. Saos-2 were plated on the disks at a density of 50,000 cells per well in 48-well dishes. After 1 hour, 1 day, 6 days cell numbers were counted. One day, 6 days after plating, alkaline phosphatase(ALPase) activity was determined. Compared to experimental group, the number of cells was significantly higher on control group. The stimulatory effect of surface roughness on ALPase was more pronounced on the experimental group than on control group. These results demonstrate that surface roughness alters proliferation and differentiation of osteoblasts. The results also suggest that implant surface roughness may play a role in determining phenotypic expression of cells.
Aluminum Oxide
;
Cell Count
;
Osteoblasts*
;
Titanium*
10.Production of Re-188.
Sang Moo LIM ; Seung Dae YANG ; Yong Sup SUH ; Sang Uk KIM
Korean Journal of Nuclear Medicine 1999;33(2):189-192
188Re (beta=22 MeV; gamma=155 keV; T1/2=16.9 hours) is an attractive therapeutic radioisotope which is produced from decay of reactor-produced tungsten-188 parent (T1/2=69 days). 188W has been produced from the double neutron capture reaction of 186W. 188Re can be easily obtained by elution of saline on alumina based 186W/188Re generator, which is commercially available. Complexes labelled with 188Re have been developed for the radiotherapy treatment of diseases because of the desirable nuclear properties of the radioisotope and it's chemical properties similar to those of technetium, a well established diagnostic agent.
Aluminum Oxide
;
Humans
;
Neutrons
;
Parents
;
Radiotherapy
;
Technetium