1.An evaluation of the stress effect of different occlusion concepts on hybrid abutment and implant supported monolithic zirconia fixed prosthesis: A finite element analysis
Nilgün Gulbahce YESILYURT ; Ali Riza TUNCDEMIR
The Journal of Advanced Prosthodontics 2021;13(4):216-225
PURPOSE:
The aim of this study is to evaluate the effects of canine guidance occlusion and group function occlusion on the degree of stress to the bone, implants, abutments, and crowns using finite element analysis (FEA).
MATERIALS AND METHODS:
This study included the implant-prosthesis system of a three-unit bridge made of monolithic zirconia and hybrid abutments. Threedimensional (3D) models of a bone-level implant system and a titanium base abutment were created using the original implant components. Two titanium implants, measuring 4 × 11 mm each, were selected. The loads were applied in two oblique directions of 15º and 30º under two occlusal movement conditions. In the canine guidance condition, loads (100 N) were applied to the canine crown only. In the group function condition, loads were applied to all three teeth. In this loading, a force of 100 N was applied to the canine, and 200-N forces were applied to each premolar. The stress distribution among all the components of the implant-bridge system was assessed using ANSYS SpaceClaim 2020 R2 software and finite element analysis.
RESULTS:
Maximum stress was found in the group function occlusion. The maximum stress increased with an increase in the angle of occlusal force.
CONCLUSION
The canine guidance occlusion with monolithic zirconia crown materials is promising for implant-supported prostheses in the canine and premolar areas.
2.An evaluation of the stress effect of different occlusion concepts on hybrid abutment and implant supported monolithic zirconia fixed prosthesis: A finite element analysis
Nilgün Gulbahce YESILYURT ; Ali Riza TUNCDEMIR
The Journal of Advanced Prosthodontics 2021;13(4):216-225
PURPOSE:
The aim of this study is to evaluate the effects of canine guidance occlusion and group function occlusion on the degree of stress to the bone, implants, abutments, and crowns using finite element analysis (FEA).
MATERIALS AND METHODS:
This study included the implant-prosthesis system of a three-unit bridge made of monolithic zirconia and hybrid abutments. Threedimensional (3D) models of a bone-level implant system and a titanium base abutment were created using the original implant components. Two titanium implants, measuring 4 × 11 mm each, were selected. The loads were applied in two oblique directions of 15º and 30º under two occlusal movement conditions. In the canine guidance condition, loads (100 N) were applied to the canine crown only. In the group function condition, loads were applied to all three teeth. In this loading, a force of 100 N was applied to the canine, and 200-N forces were applied to each premolar. The stress distribution among all the components of the implant-bridge system was assessed using ANSYS SpaceClaim 2020 R2 software and finite element analysis.
RESULTS:
Maximum stress was found in the group function occlusion. The maximum stress increased with an increase in the angle of occlusal force.
CONCLUSION
The canine guidance occlusion with monolithic zirconia crown materials is promising for implant-supported prostheses in the canine and premolar areas.
3.Effect of different provisional cement remnant cleaning procedures including Er:YAG laser on shear bond strength of ceramics.
Mustafa ZORTUK ; Hasan Onder GUMUS ; Halil Ibrahim KILINC ; Ali Riza TUNCDEMIR
The Journal of Advanced Prosthodontics 2012;4(4):192-196
PURPOSE: The purpose of this study was to evaluate the effect of provisional cement removal by different dentin cleaning protocols (dental explorer, pumice, cleaning bur, Er:YAG laser) on the shear bond strength between ceramic and dentin. MATERIALS AND METHODS: In total, 36 caries-free unrestored human third molars were selected as tooth specimens. Provisional restorations were fabricated and cemented with eugenol-free provisional cement. Then, disc-shaped ceramic specimens were fabricated and randomly assigned to four groups of dentin cleaning protocols (n = 9). Group 1 (control): Provisional cements were mechanically removed with a dental explorer. Group 2: The dentin surfaces were treated with a cleaning brush with pumice Group 3: The dentin surfaces were treated with a cleaning bur. Group 4: The provisional cements were removed by an Er:YAG laser. Self-adhesive luting cement was used to bond ceramic discs to dentin surfaces. Shear bond strength (SBS) was measured using a universal testing machine at a 0.05 mm/min crosshead speed. The data were analyzed using a Kolmogorov Smirnov, One-way ANOVA and Tukey HSD tests to perform multiple comparisons (alpha=0.05). RESULTS: The dentin cleaning methods did not significantly affect the SBS of ceramic discs to dentin as follows: dental explorer, pumice, cleaning bur, and Er:YAG laser. CONCLUSION: The use of different cleaning protocols did not affect the SBS between dentin and ceramic surfaces.
Ceramics
;
Collodion
;
Dental Porcelain
;
Dentin
;
Humans
;
Molar, Third
;
Silicates
;
Tooth
4.The effect of a diode laser and traditional irrigants on the bond strength of self-adhesive cement.
Ali Riza TUNCDEMIR ; Cihan YILDIRIM ; Erhan OZCAN ; Serdar POLAT
The Journal of Advanced Prosthodontics 2013;5(4):457-463
PURPOSE: The purpose of this study was to compare the effect of a diode laser and traditional irrigants on the bond strength of self-adhesive cement. MATERIALS AND METHODS: Fifty-five incisors extracted due to periodontal problems were used. All teeth were instrumented using a set of rotary root canal instruments. The post spaces were enlarged for a No.14 (diameter, 1.4 mm) Snowlight (Abrasive technology, OH, USA) glass fiber reinforced composite post with matching drill. The teeth were randomly divided into 5 experimental groups of 11 teeth each. The post spaces were treated with the followings: Group 1: 5 mL 0.9% physiological saline; Group 2: 5 mL 5.25% sodium hypochlorite; Group 3: 5 mL 17% ethylene diamine tetra acetic acid (EDTA), Group 4: 37% orthophosphoric acid and Group 5: Photodynamic diode laser irradiation for 1 minute after application of light-active dye solution. Snowlight posts were luted with self-adhesive resin cement. Each root was sectioned perpendicular to its long axis to create 1 mm thick specimens. The push-out bond strength test method was used to measure bond strength. One tooth from each group was processed for scanning electron microscopic analysis. RESULTS: Bond strength values were as follow: Group 1 = 4.15 MPa; Group 2 = 3.00 MPa; Group 3 = 4.45 MPa; Group 4 = 6.96 MPa; and Group 5 = 8.93 MPa. These values were analysed using one-way ANOVA and Tukey honestly significant difference test (P<.05). Significantly higher bond strength values were obtained with the diode laser and orthophosphoric acid (P<.05). There were no differences found between the other groups (P>.05). CONCLUSION: Orthophosphoric acid and EDTA were more effective methods for removing the smear layer than the diode laser. However, the diode laser and orthophosphoric acid were more effective at the cement dentin interface than the EDTA, Therefore, modifying the smear layer may be more effective when a self-adhesive system is used.
Acetic Acid
;
Axis, Cervical Vertebra
;
Characidae
;
Dental Pulp Cavity
;
Dentin
;
Edetic Acid
;
Ethylenes
;
Glass
;
Incisor
;
Lasers, Semiconductor*
;
Methods
;
Phosphoric Acids
;
Resin Cements
;
Smear Layer
;
Sodium Hypochlorite
;
Tooth
5.The effect of repeated porcelain firings on corrosion resistance of different dental alloys.
Ali Riza TUNCDEMIR ; Ismail KARAHAN ; Serdar POLAT ; Meral Arslan MALKOC ; Mehmet DALKIZ
The Journal of Advanced Prosthodontics 2013;5(1):44-50
PURPOSE: The aim of this study was to evaluate the effects of repeated porcelain firing process on the corrosion rates of the dental alloys. MATERIALS AND METHODS: Cr-Co, Cr-Ni and Pd-Ag alloys were used for this study. Each metal supported porcelain consisted of 30 specimens of 10 for 7, 9 and 11 firing each. Disc-shaped specimens 10 mm diameter and 3 mm thickness were formed by melting alloys with a propane-oxygen flame and casted with a centrifuge casting machine and then with the porcelain veneer fired onto the metal alloys. Corrosion tests were performed in quintuplicate for each alloy (after repeated porcelain firing) in Fusayama artificial saliva solution (pH = 5) in a low thermal-expansion borosilicate glass cell. Tamhane and Sheffe test was used to compare corrosion differences in the results after repeated firings and among 7, 9 and 11 firing for each alloy. The probability level for statistical significance was set at alpha=0.05. RESULTS: The corrosion resistance was higher (30 mV), in case of 7 times firing (Commercial). On the other hand, it was lower in case of 11 times firing (5 mV) (P<.05). CONCLUSION: Repeated firings decreased corrosion resistance of Pd-Ag, Cr-Co and Cr-Ni alloys. The Pd-Ag alloy exhibited little corrosion in in vitro tests. The Cr-Ni alloy exhibited higher corrosion resistance than Cr-Co alloys in in vitro tests.
Alloys
;
Corrosion
;
Dental Alloys
;
Dental Porcelain
;
Fires
;
Freezing
;
Glass
;
Hand
;
Saliva, Artificial